2293 SQ. FT./300=8.77xl44=1263.83/2=631.9/16.9=37.39 LINEAR FEET <br />OF RIDGE VENT IS REQUIRED FOR VENTILATION OF ATTIC SPACE <br />FL. #5027 <br />GAF MASTERFLOW AR-10 RIDGE VENT (OR EQUAL) <br />RIDGE VENT <br />FIBERGLASS SHINGLES ON <br />15# FELT & 7/16' STRUCTURAL 1 O.S.B, <br />OR 15/32' EXPOSURE 1 CD PLYWOOD, <br />5 INSTALL PLYWOOD CLIPS C24' O.C. <br />CEILING LINE CEILING LINE CEILING LINE <br />_FLOOR LINE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- <br />LEFT SIDE ELEVATION SCALE 1/4• _ 1-0� <br />CEILING LINE <br />s <br />0 <br />I <br />00 <br />I <br />I <br />GARAGE FLOOR LINE I _ _ _ _ _ _LIVING AREA FLOOR LINE <br />------------------------------------ <br />RIGHT SIDE ELEVATION SCALD 1/4� _ 1-0• <br />0 <br />I <br />d0--------------- <br />CEMENTACIOUS FINISH <br />CEILING LINE <br />RIDGE VENT <br />FINISH ON TRUSS ENDS <br />STUCCO ON METAL LATH OVER <2) LAYERS <br />OF 15# FELT OR (1) LAYER OF 15# FELT <br />& (1) LAYER OF TYVEK OVER <br />7/16' STRUCTURAL 1 O.S.B. OR 15/32' <br />EXPOSURE 1 CD PLYWOOD SHEATHING WITH <br />8d NAILS 6' O.C. <br />--------- ------------ /-- STUBBED OFF TRUSSES---------_--- <br />FLOOR LINE________________�__ <br />REAR ELEVATION SCALE: 1/4•=1-0• <br />6' <br />0 <br />I---------------- <br />CEMENTACIOUS FINISH <br />::IN <br />% r" <br />FLOOR LINE_--_-_-_ ---- <br />0� <br />it <br />00 <br />p 0 <br />FRONT ELEVATI❑N SCALE: 1/4 = 1-0' <br />GENERAL NOTES <br />THE DESIGN OF THIS STRUCTURE HAS BEEN REVIEWED FOR COMPLIANCE WITH THE WINDLOAD PROVISIONS OF FBC BUILDING, <br />SIXTH EDITION 2017 <br />ULTIMATE WIND SPEED =140 MPH <br />NOMINAL WIND SPEED =108 MPH <br />IMPORTANCE FACTOR =1.0 (BUILDING CATEGORY II) <br />EXPOSURE CATEGORY = B (ALL DIRECTIONS) <br />INTERNAL PRESSURE COEFFICIENT = + 0.18 <br />1. COMPONENTS AND CLADDING WIND PRESSURES TO BE USED FOR DESIGN OF EXTERIOR COMPONENT AND CLADDING <br />MATERIALS SHALL ABE IN COMPLIANCE WITH ASCE 7-10 CHAPTER 30 AS FOLLOWS: <br />EFFECTIVE WIND AREA ZONE <br />1 2 3 4 5 <br />A UP TO 10 S.F. +20.3, -32.3 +20.3, -56.2 +20.3, -83.1 +35.3, -38.2 +35.3, -47.2 <br />B UP TO 20 S.F. +18.5, -31.4 +18.5, -51.7 +18.5, -77.7 +37.7, -36.7 +33.7, -44.0 <br />C UP TO 50 S.F. +16.1, -30.2 +16.1, -45.7 +16.1, -70.5 +31.6, -34.6 +31.6, -39.8 <br />D UP TO 100 S.F. +14.3, -29.3 +14.3, -41.2 +14.3, -65.1 +30.0, -33.0 +30.0, -36.7 <br />E OVER 100 S.F. +14.3, -29.3 +14.3, -41.2 +14.3, -65.1 +30.0, -33.0 +30.0, -36.7 <br />2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE, BUILDING. <br />3. DESIGN LIVE LOADS USED IN THE DESIGN DEAD LOADS USED IN THE <br />ANALYSIS AREAS FOLLOWS: ANALYSIS ARE AS FOLLOWS: <br />- ROOF = 20 PSF - FLOORS = 40 PSF <br />- FLOORS = 40 PSF - ROOF: SHINGLE = 47 PSF <br />- GARAGE FLOOR = 50 PSF TILE = 65 PSF <br />- BALCONIES = 60 PSF <br />- PORCHES, LOFTS, DECKS = 40 PSF <br />4. CONCRETE FOUNDATIONS SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 18, FBCB. SUBSURFACE GEOTECHNICAL <br />INFORMATION HAS NOT BEEN PROVIDED TO THE ENGINEER. THEREFORE FOUNDATIONS AND FOOTINGS ARE DISIGNED FOR THE <br />FOLLOWING ASSUMED SOIL BEARING CONDITIONS: LOOSE GRANULAR MATERIAL WITH NO APPRECIABLE CLAY OR ORGANIC <br />MATERIAL WITH A MINIMUM ALLOWABLE BEARING PRESSURE OF 2000 PSF PER FBCB TABLE 1806.2 COMPACT FILL TO 95% <br />MODIFIED PROCTOR. <br />5. MASONRY CONSTRUCTION SHALL CONFORM TO REQUIREMENTS OF CHAPTER 21, FBCB. NET AREA COMPRESSIVE STRENGTH OF <br />MASONRY IS 1500 PSI. TYPE M, OR S MORTAR SHALL BE USED. ALL MASONRY SHALL BE LAID IN RUNNING BOND PATTERN WITH <br />HEAD JOINTS IN SUCCESSIVE COURSES OFFSET BY NOT LESS THAN ONE-FOURTH THE UNIT LENGTH. THICKNESS OF BED JOINTS <br />SHALL NOT EXCEED %". GLASS UNIT MASONRY SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 2110, FBCB. <br />6. GROUT USED TO FILL CELLS, LINTELS AND BOND BEAMS SHALL CONFORM TO REQUIREMENTS OF ASTM C476 AND CHAPTER 21, <br />FBCB. REQUIRED MINIMUM COMPRESSIVE STRENGTH IS 2000 PSI AT 28 DAYS. <br />7. CONCRETE SHALL CONFORM TO REQUIREMENTS OF CHAPTER 19, FBCB, AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF <br />3000 PSI AT 28 DAYS UNLESS OTHERWISE SPECIFIED. <br />8. REINFORCING BARS SHALL BE GRADE 40 OR 60 DEFORMED BILLET STEEL BARS AND COMPLY WITH ASTM A 615 <br />REQUIREMENTS. JOINT REINFORCING IF USED SHALL BE 9 GAGE, GALVANIZED STEEL CONFORMING TO ASTM A82 <br />REQUIREMENTS. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 REQUIREMENTS. WIRE FABRIC SHALL BE SUPPORTED <br />AS REQUIRED IN SECTIN01910, FBCB. SYNTHETIC FIBER REINFORCEMENT SHALL CONFORM TO REQUIREMENTS OF SECTION <br />1910, FBCB. <br />9. WOOD ROOF AND WALL SHEATHING SHALL BE APA-RATED PANELS AND CONFORM TO REQUIREMENTS OF CHAPTER 23, FBCB. <br />WOOD STRUCTURAL PANEL DIAPHRAGM NAIL SPACING ALONG PANEL EDGES SHALL BE 6" O.C. AND INTERMEDIATE FASTENERS <br />SHALL BE AT 12" O.C. UNLESS NOTED OTHERWISE. FASTENERS SHALL BE 8D COMMON NAILS, UNLESS OTHERWISE NOTED. <br />THICKNESS OF WOOD PANELS IS NOTED ON THE DRAWINGS. <br />10, WOOD STUDS AND GIRDER SUPPORT POSTS USED FOR BEARING WALL FRAMING OF LESS THAN 10; PLATE HEIGHT SHALL BE <br />HEM -FIR, S-P-F; OR S-Y-P, STUD GRADE OR BETTER WOOD STUDS AND GIRDER SUPPORT POSTS USED FOR BEARING WALL <br />FRAMING WITH 10' PLATE HEIGHT AND HIGHER SHALL BE HEM -FIR, S-P-F; OR, S-Y-P #2 GRADE OR BETTER. ALL POSTS UNDER <br />GIRDERS SHALL HAVE A MINIMUM OF 1 STUD PER GIRDER PLY. WALL OPENINGS SHALL BE CONSTRUCTED IN ACCORDANCE WITH <br />CHAPTER 23, SECTION 2308.95, AND 2308.9.6. FBCB, UNLESS OTHERWISE NOTED. WOOD BEAMS, HEADERS, RAFTERS AND <br />OTHER HORIZONTAL LOAD BEARING ELEMENTS SHALL. BE S-Y-P #2 GRADE OR BETTER. <br />11. FASTENING OF WOOD FRAMING SHALL CONFORM TO TABLE 2304.9.1, FBCB, UNLESS OTHERWISE NOTED. <br />12. DESIGN OF PREFABRICATED WOOD TRUSSES IN FLOORS AND ROOFS IS DELEGATED TO THE TRUSS MANUFACTURER'S <br />ENGINEER. THE TRUSS ENGINEER SHALL SUBMIT ENGINEERING DOCUMENTS FOR REVIEW FOR CONFORMANCE WITH THE <br />DESIGN INTENT OF THE PROJECT. INSTALLATION OF PREFABRICATED WOOD TRUSSES SHALL FOLLOW THE RECOMMENDATIONS <br />OF THE MANUFACTURER THE CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL TEMPORARY AND PERMANENT TRUSS <br />BRACING REQUIRED BY THE MANUFACTURER IN ADDITION TO ANY SUPPLEMENTAL BRACING SHOWN ON THESE DRAWINGS. <br />13. WOOD CONSTRUCTION CONNECTORS SHOWN ON THE DRAWINGS REPRESENT THE DESIGNER'S INTENT TO FURNISH A <br />COMPLETE LOAD PATH FROM ROOF TO FOUNDATION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING <br />THE SPECIFIED CONNECTOR OR A SUBSTITUTE CONNECTOR WITH DOCUMENTED EQUIVALENT CAPACITY. <br />14. DEVIATIONS FROM THESE DRAWINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND OWNER, MODIFICATIONS OF <br />STRUCTURAL DETAILS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO PROCEEDING WITH THE <br />MODIFICATION. ALL CHANGES TO STRUCTURAL DETAILS CONSTRUCTED WITHOUT PRIOR APPROVAL OF THE ENGINEER ARE AT <br />THE CONTRACTOR'S AND OWNER'S RISK. <br />THESE NOTES COMPILED BY MICHAEL D. WILBURN, P.E. <br />15 5 <br />d <br />DESIGN LOADS: <br />WIND LOADING =140 MPH <br />TCLL = 20 PSF <br />TCDL = 7 PSF (SHINGLES/METAL) <br />TCDL = 15 PSF (TILES) <br />BCDL 10 PSF <br />ALL FLOOR DESIGN LOADS = 40 PSF (FLOOR DESIGN LOADS ARE APPLICABLE TO STAIRS ALSO) <br />PRE -MANUFACTURED TRUSSES TO BE DESIGNED BY A FLORIDA REGISTERED ENGINEER. <br />ENGINEER OF RECORD ASSUMPTIONS: <br />THESE DRAWINGS WERE PREPARED WITH THE ASSUMPTION THAT THE CONTRACTOR OR OWNER -BUILDER IS <br />KNOWLEDGEABLE OF COMMON CONSTRUCTION PRACTICES. <br />THE CONTRACTOR / OWNER -BUILDER SHALL REVIEW DRAWINGS FOR ACCURACE AND INTERPRETATION. ANY <br />DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER/ARCHITECT/DRAFTSMAN PRIOR TO <br />BID OR CONSTRUCTION. <br />THE CONTRACTOR / OWNER -BUILDER IS TO VERIFY THAT TRUSS ENGINEERINGAND DESIGN IS COMPATIBLE <br />WITH THESE DRAWINGS PRIOR TO TRUSS FABRICATION. <br />THE FOUNDATION PLAN SHALL BE VERIFIED BY THE CONTRACTOR / OWNER -BUILDER TO CORRESPOND WITH <br />THE FINAL ENGINEERED TRUSS LAYOUT. <br />DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. DO NOT SCALE DRAWINGS. <br />THIS BUILDING DESIGN COMPLIES WITH CHAPTER 16 OF THE 2017 FLORIDA BUILDING CODE. <br />ALL EXTERIOR WALLS BETWEEN OPENINGS ARE DESIGNED AS AND SHOULD BE CONSIDERED SHEARWALLS. <br />ASPHALT SHINGLES, WHEN USED, SHALL COMPLY WITH ASTM D225 OR ASTM D 3462 AND SHALL <br />HAVE FACTORY APPLIED SELF -SEAL STRIPS OR BE INTERLOCKING. <br />APPLICABLE FLORIDA CODES: <br />FLORIDA BUILDING CODE - BUILDING, 2017 EDITION <br />FLORIDA BUILDING CODE - RESIDENTIAL, 2017 EDITION <br />FLORIDA BUILDING CODE - PLUMBING, 2017 EDITION <br />FLORIDA BUILDING CODE - MECHANICAL 2017 EDITION <br />FLORIDA BUILDING CODE - BUILDING CHAPTER 11 ACCESSIBILITY, 2017 EDITION <br />FLORIDA BUILDING CODE - ENERGY EFFICIENCY, 2017 EDITION <br />NFPA 70 NATIONAL ELECTRICAL CODE, 2015 EDITION <br />1609 DESIGN CRITERIA <br />BASIC WIND SPEED (3-SECOND GUST) =140 MPH <br />WIND IMPORTANCE FACTOR =1.0 <br />WIND EXPOSURE CATEGORY = B <br />INTERNAL PRESSURE COEFFICIENT = .18 <br />BUILDING CATEGORY=11 <br />FULLY ENCLOSED DESIGN <br />SURFACE ROUGHNESS CATEGORY= B <br />THE DESIGN OF THIS STRUCTURE HAS BEEN REVIEWED FOR COMPLIANCE BY MICHAEL D. WILBURN, <br />P.E. WITH THE WINDLOAD PROVISIONS OF 2017 FLORIDA BUILDING CODE & ASCE/SEI 7-10 MINIMUM <br />DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES & CHAPTER 30 COMPONENTS AND CLADDING <br />PART J: LOW RISE BUILDING USING THE FOLLOWING CRITERIA: RISK CATEGORY II BASIC WIND SPEED <br />139 MPH, EXPOSURE CATEGORY = B INTERNAL PRESSURE COEFFICIENT +/- 0.18. <br />DESIGNED TO EXCEED FLORIDA BUILDING CODE <br />SIXTH EDITION 2017 <br />STRUCTURAL DESIGN - (ENCLOSED) <br />BASIC WIND SPEED 140 MPH (3 SECOND GUST), NOMINAL 108 MPH <br />WIND EXPOSURE CATEGORY "B" (ALL DIRECTIONS) <br />BUILDING CATEGORY CLASSIFICATION - V-B <br />FLOOD ZONE DESIGNATION - X ALL <br />TYPE OF ROOF COVERING - FIBERGLASS SHINGLES CODES FLORIDA BlC1tOLp �iG yyITH PREVAILING <br />TOTAL SQUARE FEET OF RESIDENCE - 2293 SQ. FT. NATIONAL ELECTRIC CODE,G CODE, <br />INTERNAL COEFFICIENT +/- 0.18 ENCLOSED +/- 0.57 UNENC8RCME <br />CN ECTRI OF 11.LS <br />IMPORTANCE FACTOR 1.0 QINANCES <br />COMPONENTS AND CLADDING +/- 37.5 PSF <br />w OF �-r <br />S <br />DON <br />ENS�' <br />No. 76061 <br />'�� FL QR1DP. •' GN <br />/ONAL E <br />z <br />LD <br />"t <br />0 cy <br />o <br />Ld q- <br />Q <br />U <br />06 � <br />LY <br />Q� <br />Q <br />Z q <br />}' <br />r pq <br />CO <br />� Cj:� <br />� � <br />LO Q <br />;4-� <br />0 <br />C1J <br /><E <br />(') <br />F- <br />caj <br />j <br />0 H <br />C__) <br />CU CD <br />LD <br />r <br />t� <br /><L <br />C'') <br /><E <br />LJ Q <br />ry <br />�-- p <br /><L <br />� J <br />� <br />Q <br />pq <br />0 <br />W <br />In 0 <br />1 <br />100 <br />0 <br />C� <br />'--i <br />CD <br />kD <br />`o# <br />d <br />U) cu <br />u Ln <br />LL <br />Q1 _ <br />QJ (y) <br />_u <br />V <br />J <br />(� <br />V ! <br />0 <br />O <br />W <br />00 <br />0 <br />M <br />c--I <br />o <br />V J <br />00 <br />D <br />u <br />U• <br />F----I <br />Q <br />>Zli <br />SHEET 1 OF <br />5 <br />