4918, 4920 8th St and 20th St
Zephyrhills
>
Building Department
>
Building Plans
>
4918, 4920 8th St and 20th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:47:41 AM
Creation date
2/19/2025 12:48:30 PM
Metadata
Fields
Template:
Building Plans
Street #
4918, 4920
Location
8th St and 20th St
Contractor
J Bryant Construction
Building Plans - Permit #
3131 and 3128
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL NOTES <br />1.: ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE APPROPRIATE <br />::ARTICLES OF THE NATIONAL ELECTRICAL CODES (NEC). <br />2. WHEN LIGHT FIXTURES ARE INSTALLED IN CLOSETS THEY SHALL BE SURFACE MOUNTED OR RECESSED. <br />,.,JNCANDESCENT FIXTURES SHALL HAVE COMPLETELY ENCLOSED LAMPS. SURFACE MOUNTED <br />INCANDESCENT FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 12 INCHES AND ALL OTHER FIXTURES <br />SHALL HAVE A MINIMUM CLEARANCE OF 6 INCHES FROM " STORAGE AREA" AS DEFINED BY NEC 410-8 (a) <br />3. WHEN WATER HEATERS ARE INSTALLED THEY SHALL BE PROVIDED WITH READILY ACCESSIBLE <br />DISCONNECTS ADJACENT TO THE WATER HEATERS SERVED. THE BRANCH CIRCUIT SWITCH OR CIRCUIT <br />BREAKER SHALL BE PERMITTED TO SERVE AS THE DISCONNECTING MEANS ONLY WHERE THE SWITCH <br />OR CIRCUIT BREAKER IS WITHIN SIGHT FROM THE WATER HEATER OR IS CAPABLE OF BEING LOCKED <br />IN THE OPEN POISON, <br />4. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS ADJACENT TO THE <br />EQUIPMENT SERVED. A UNIT SWITCH WITH A MARKED " OFF " POSITION THAT IS A PART OF THE HVAC <br />EQUIPMENT AND DISCONNECTS ALL UNGROUNDED CONDUCTORS SHALL BE PERMITTED.AS THE <br />DISCONNECTING MEANS WHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY A READILY <br />ACCESSIBLE CIRCUIT BREAKER. <br />5. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING OF THE MAIN BREAKER <br />MUST BE DESIGNED AND VERIFIED AS BEING IN COMPLIANCE WITH SECTION 110-9 OF THE NEC BY <br />LOCAL ELECTRICAL CONSULTANT. <br />6. EXTERIOR LIGHTS NOT INTENDED FOR 24 HOUR USE AND SHALL BE CONNECTED TO A PHOTOCELL OR <br />TIMER. <br />7. ALL RECEPTACLES INSTALLED IN WET LOCATIONS (EXTERIOR) SHALL BE IN WEATHER PROOF (W.P.) <br />ENCLOSURES. THE INTEGRITY OF WHICH IS NOT AFFECTED WHEN AN ATTACHMENT PLUG CAP IS <br />INSERTED OR REMOVED. <br />8. WHEN NOT SHOWN ON THE PLANS PROVISIONS FOR EXIT DISCHARGE LIGHTING (INCLUDING EXIT <br />DISCHARGE EMERGENCY LIGHTING) ARE DESIGNED BY OTHERS AND THE RESPONSIBILITY OF THE <br />BUILDINGS OWNER AND SUBJECT TO LOCAL JURISDICTION APPROVAL. <br />SMOKE ALARM NOTES <br />NOTE: SMOKE ALARMS SHALL NOT BE INSTALLED IN THE FOLLOWING LOCATIONS UNLESS THIS WOULD PREVENT <br />PLACEMENT OF A SMOKE ALARM IN A LOCATION REQUIRED BY SECTION 907.2.11.1 OR 907.2.11.2: <br />1. IONIZATION SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 20 FEET HORIZONTALLY FROM A <br />PERMANENTLY INSTALLED COOKING APPLIANCES. <br />2. IONIZATION SMOKE ALARMS WITH AN ALARM -SILENCING SWITCH SHALL NOT BE INSTALLED LESS THAN 10 <br />FEET HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. <br />3. PHOTOELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FEET HORIZONTALLY FROM A <br />PERMANENTLY INSTALLED COOKING APPLIANCE. <br />NOTE: ALL SMOKE ALARMS WITHIN THE SLEEPING UNIT OR DWELLING UNIT IN GROUP R OR 1-1 OCCUPANCIES SHALL <br />BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE OTHER <br />ALARMS IN THE INDIVIDUAL UNIT. PHYSICAL CONNECTION OF SMOKE ALARMS SHALL NOT BE REQUIRED WHERE <br />LISTED WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND UPON ACTIVATION OF ONE ALARM. THE ALARM <br />SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS <br />CLOSED. (FBC 907.2.11.5) <br />NOTE: SINGLE OR MULTI -STATION SMOKE ALARMS SHALL BE INSTALLED AND MAINTAINED AT ALL OF THE FOLLOWING <br />LOCATIONS: <br />1.ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF <br />BEDROOMS. <br />2.IN EACH ROOM USED FOR SLEEPING PURPOSES. <br />3.IN EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND <br />UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING <br />DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR <br />THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE <br />UPPER LEVEL. (FBC 907.2.9.2) (FBC 907.2.11.2) <br />ELECTRICAL LEGEND <br />DUPLEX RECEPT @ 16" A.F.F. <br />CEILING MOUNT EXHAUST FAN <br />DUPLEX RECEPT @ 42" A.F.F. <br />® <br />EXHAUST FAN / LIGHT COMBO <br />QUAD RECEPT @ 16" A.F.F. <br />EMERGENCY LIGHTING <br />220 VOLT RECEPTACLE <br />Q® <br />EXIT SIGNAGE - DIRECTIONAL <br />G.F.I. DUPLEX RECEPTACLE <br />WATER PROOF PORCH LIGHT 60W. <br />W/ WEATHERPROOF COVER <br />MAXIMUM WITH PHOTO CELL <br />Q <br />PHONE JACK @ 16" A.F.F. <br />Q®D <br />EMERGENCY LIGHT/ EXIT COMBO <br />PHONE JACK @ 42" A.F.F. <br />�O\ <br />INCANDESCENT LIGHT 15/25W MAX <br />V <br />DATA OUTLET @ 16" A.F.F. <br />FLUORESCENT FIXTURE <br />Z <br />24"x24" SUPPLY AIR REGISTER <br />J❑ <br />ELECTRICAL JUNCTION BOX <br />® <br />24"x24" RETURN AIR <br />QT <br />WALL MOUNTED THERMOSTAT <br />WALL MOUNTED SWITCH <br />® <br />FIRE ALARM STROBE <br />OCCUPANCY SENSOR <br />FIRE ALARM HORN STROBE <br />ao <br />EEMAX WATER HEATER <br />® <br />FIRE ALARM PULL STATION <br />sD <br />SMOKE DETECTOR <br />O° <br />MONOXIDE DETECTOR <br />HD <br />HEAT DETECTOR <br />MD <br />SEC MOTION DETECTOR <br />ccTV <br />SEC CCTV CAMERA <br />KF <br />SEC KEY FOB ENTRY <br />0 <br />€\\\\\\\�� <br />\ <br />J <br />LL <br />r <br />CO <br />❑ Cf) <br />a <br />J <br />00 <br />N <br />" ` <br />U) LL <br />00 <br />Lo <br />...LLI <br />Q <br />M <br />>.z <br />N `_C <br />\Lo <br />J <br />> <br />i <br />Is", <br />Z <br />. <br />ry <br />W <br />�- <br />W <br />> <br />H <br />W <br />Z <br />�00 <br />NZ <br />Qz <br />�cco <br />O J <br />ti<t <br />00 <br />W <br />JLIJ <br />O LL. <br />(' Z <br />0 V <br />C] Q <br />W W <br />L = <br />Z W <br />�::) <br />WV <br />00 <br />m <br />�¢ <br />�0 <br />O <br />cf) <br />00' <br />cj <br />T <br />CL <br />z <br />W <br />0 <br />z <br />'t <br />Q <br />a. <br />Z <br />owMQ <br />o <br />ULLI <br />Ce)U <br />i <br />U <br />�U) <br />^F <br />W=�LLJ <br />ZOO <br />O_ <br />(-) <br />I.0 <br />U <br />Z <br />w0W0 <br />z <br />NO <br />O <br />EL <br />i <br />w <br />Z <br />O <br />W <br />ry <br />Digl ly <br />signed <br />a ` T 4p <br />Robert T <br />�04�� <br />a � ,����srereFo. Gea <br />e <br />Haug <br />24575 ¢g <br />STATE OF �= <br />zp ;. =ws <br />r8 <br />Date: <br />Kos'• F�l?Ci1�P. <br />2021.06J 0 <br />16:25:4 <br />_0 , <br />W <br />co <br />w <br />Z <br />LO <br />(D iS <br />1 <br />o J w Q <br />j �' ® oN <br />C� <br />Z <br />Q N <br />c <br />0 > <br />w <br />W <br />=Q:tt <br />❑ W <br />c4 <br />C7 <br />~ O� vi <br />w <br />wOU <br />1— <br />ca <br />w <br />z Y <br />chi) <br />w <br />z <br />a <br />= 66 <br />O <br />Q p <br />SHEET NO. <br />........... ......._..._..................... ...... ........... ..................... -............................. ..._........... ....:................................. ............................ .................................... ............._........................... <br />.....: <br />0 <br />W © COPYRIGHT 2021 - ELEMENT ARCHITECTURAL VISUALIZATION <br />