My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5023 18th St
Zephyrhills
>
Building Department
>
Building Plans
>
5023 18th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:52:23 AM
Creation date
2/19/2025 12:48:42 PM
Metadata
Fields
Template:
Building Plans
Street #
5023
Location
18th St
Contractor
301 Development
Building Plans - Permit #
3375
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r. L . 1' -',, L!' I I 11 .. I i v I I'. 1 I I' 1. _ 11 1 1 I 1 1 1 1 1 1 11 I _ I I I 1 - <br />ELECTRICAL - DATA - AUDIO LEGEND <br />SYMBOL <br />DESCRIPTION <br />Ceiling Fan <br />HVentilation <br />Fans: Ceiling Mounted, Wall Mounted <br />0 g (j) g <br />Ceiling Mounted Light Fixtures: Surface/Pendant, <br />Recessed, Heat Lamp, Low Voltage <br />® <br />Wall Mounted Light Fixtures: Flush Mounted, <br />Wall Sconce <br />Chandelier Light Fixture <br />Fluorescent Light Fixture <br />240V Receptacle <br />(p WP�4GFCO <br />110V Receptacles: Duplex, Weather Proof, GFCI <br />WP 3y 4� <br />Switches: Single Pole, Weather Proof, 3-Way, 4-Way <br />DM $ Ty <br />`y+� <br />Switches: Dimmer, Timer <br />AV Control A$ <br />Audio Video: Control Panel, Switch <br />sP sP <br />Speakers: Ceiling Mounted, Wall Mounted <br />C5� c g 1T d <br />Wall Jacks: CATS, CATS + TV, TV/Cable <br />�7_ <br />Telephone Jack <br />Intercom <br />Q <br />Thermostat <br />a Q <br />Door Chime, Door Bell Button <br />O/ D COOISD <br />COMBINATION CO2 / Smoke Detectors: Ceiling Mounted, Wall Mounted <br />® EP <br />Electrical Breaker Panel <br />UNDERGROUND METER <br />_- HUB SUPPLIED BY <br />\POWER COMPANY <br />MAIN <br />BREAKER <br />BOX <br />T_UNDER&ROUND CONDUIT <br />SUPPLIED BY PROPERTY MOUNT ALL VANITY SCONCES AT 84" TO CENTER— - <br />OWNER TO ELECTRIC HB <br />COMPANY FEEDER LINE. D <br />�✓ <br />GROUND RODS ELECTRIC R15ER <br />° ° <br />NOT TO SCALE — -- — <br />ALL ELECTRICAL SHALL COMPLY WITH FLORIDA BUILDING CODE CHAPTER 27 AND NFPA 70A <br />NATIONAL ELECTRIC CODE FOR ONE AND TWO FAMILY DWELLINGS. <br />CONTRACTOR SHALL CONDUCT PRE -ELECTRICAL INSTALLATION WALK THROUGH WITH <br />HOMEOWNER TO VERIFY SPECIFIC PLACEMENT OF LIGHTS, SWITCHES, AND FANS. <br />PER NFPA 72 & FBC R314 <br />Install smoke alarms inside each bedroom, outside each sleeping area and on every level of the <br />home, including the basement. <br />On levels without bedrooms, install alarms in the living room (or den or family room) or near the <br />stairway to the upper level, or in both locations. <br />PORCH <br />BEJROOM 1 <br />I/ CO/SD <br />DW C O FCI O <br />I <br />1\ � FCI <br />COORDINATE \ <br />W/ LOC. OF <br />TABLE DINING —i \ M GFCI I / / — <br />/ I <br />R <br />� I CO/SD <br />COORDINATE <br />W/ LOC. OF <br />ISLAND � <br />LIVING \ <br />( I <br />I I <br />\ � 1 <br />I <br />� I i <br />/I <br />Smoke alarms should be installed at least 10 feet (3 meters) from a cooking appliance to 3 3 <br />minimize false alarms when cooking & Smoke alarms shall be installed not less than 3 feet (914 / <br />mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower <br />unless this would prevent placement of a smoke alarm required by other sections of this code. 1 / <br />Mount smoke alarms high on walls or ceilings. Wall -mounted alarms should be installed not more 1 / <br />than 12 inches away from the ceiling (to the top of the alarm). / <br />On pitched ceilings, install the alarm within 3 feet of the peak but not within the apex of the peak I ' WP <br />(four inches down from the peak). PORCH <br />I I <br />Smoke alarms shall be placed not less than 36" from the tip of the ceiling fan blade and not less I I <br />than 36" from HVAC vents I <br />ALL ELECTRICAL OUTLETS SHALL BE PLACED PER THE FBC AND NFPA 70A AS REQUIRED \ <br />\ I <br />All electrical outlets located within six feet of a sink or other water source must have a ground- \ I <br />fault circuit -interrupter (GFCI) <br />All outlets and switches placed outdoors must be inside a weather protective box \ \ <br />Provide carbon monoxide detector within 10ft of each bedroom entrance \ \ <br />Place hard wired, interconnected smoke detectors with battery back up inside of every sleeping <br />area and adjacent hallways and living areas. <br />ALL SMOKE ALARMS SHALL BE HARDWIRED, INTERCONNECTED W/ BATTERY BACK UP <br />ALL BATHROOMS & TOILET ROOMS SHALL BE EQUIPPED WITH MINIMUM 50CFM VENTILATION <br />TO EXTERIOR OR AS REQUIRED BY FBC R303.3 <br />TYPE, STYLE, AND LOCATION OF SWITCHES AND LIGHTS SHALL BE COORDINATED BETWEEN <br />OWNER AND CONTRACTOR DURING ELECTRICAL ROUGH IN <br />OWNER TO SPECIFY LOCATION OF DATA, CABLE, AND LOW VOLTAGE WIRING DURING <br />ELECTRICAL ROUGH IN <br />a <br />T <br />W BEDROOM 3 <br />CO/SD <br />W3 % / _- WH A/C, <br />CONDENSER <br />I AIR <br />HANDLER <br />1 <br />\ GARAGE <br />� R CE <br />150 AMP <br />MAIN <br />ELECTRICAL <br />PANEL <br />--— — — — — ---I <br />ELECTRICAL <br />METER <br />FDJ ENGINEERING AND DE516N, <br />LLG <br />CERT. OF AUTHORIZATION 0 90%6 <br />FRANKOFOJENG.COM <br />ENGINEERING CERTIFICATICATION <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THE <br />ATTACHED DESIGN AND FOUND IT TO BE IN <br />COMPLIANCE WITH THE FLORIDA UILDING CODE, <br />7TH EDITION (2020) - RESIDENTI <br />THIS DRAWING AND DE51ON 15 VA FOR <br />MONTHS AFTER THE DATE IT 15 516 - AND <br />SEALED <br />i <br />THIS DRAWING AND DESIGN 15 516NED AND <br />5EALED FOR STRUCTURAL ENGINEERING ONLY. <br />FRANK A DEJ05E PE <br />FL PE #13539 <br />GENERAL NOTES: <br />1. GC TO VERIFY ALL ELECTRICAL <br />FIN15HE5 AND ACCE55ORIE5 PRIOR <br />TO ORDER / IN5TALL, TYP. <br />2. GC TO COORDINATE WITH <br />ELECTRICAL CONTRACTOR AND <br />OWNER PRIOR TO ELECTRICAL <br />ROUGH IN. <br />3. GC, ELECTRICAL CONTRACTOR, <br />AND OWNER SHALL CONDUCT PRE - <br />ROUGH IN WALK THROUGH, IN ORDER <br />TO SPECIFY ANY 5PECIAL <br />ELECTRICAL REQUIREMENT5 <br />O <br />N <br />w <br />Ca <br />}- <br />m <br />w <br />m <br />[] <br />w <br />Z <br />LU <br />>. <br />w <br />�w <br />I-- <br />Q <br />w <br />m <br />Z <br />Z <br />0L <br />v <br />v <br />Ul <br />U1 <br />MWAA14 <br />11/17/2021 <br />SCALE: <br />1 /4"=1 '-0" <br />SHEET: <br />E-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.