SP1 AT EACH STUD <br />FLOOR FRAMING BELOW <br />EXISTING DOUBLE TOP PLATE. <br />REPLACE EXISTING <br />CONNECTIONS TO ROOF <br />RAFTERS IN KIND OR PROVIDE <br />(2) H2.5A CONNECTOR AT <br />EACH RAFTER <br />SP2 AT EACH STUD <br />CONT. BLOCKING AT <br />MIDSPAN W/ (2) 10d TOE <br />NAILS AT EACH END. <br />EXISTING SINGLE SOLE <br />PLATE. WHERE PROVIDING <br />NEW SOLE PLATE, ATTACH <br />TO FRAMING BELOW WITH <br />DIA. LAG SCREWS AT 8" O.C. <br />1. PLYWOOD SHEATHING, IS NOT SHOWN FOR CLARITY. <br />2. SEE WOOD FASTENING SCHEDULE FOR MINIMUM <br />NAILING REQUIREMENTS. <br />STUD INFILL DETAIL OF <br />EXISTING OPENING <br />SP4 AT EACH KING STUD <br />WRAPPED OVER TOP <br />PLATE. <br />KING STUD(S). <br />MSTA12 AT EACH END <br />(1) JACK STUD AT OPENINGS <br />T-0" WIDE OR LESS. (2) JACK <br />STUDS AT OPENINGS <br />GREATER THAN T-0" WIDE. <br />H6 SIMPSON STRAP TO <br />FRAMING BELOW AT <br />KING & JACK <br />FLOOR FRAMING BELOW <br />SCALE: NTS <br />DOUBLE TOP PLATE. <br />SEE PLAN NOTES. <br />SP2 U.N.O. ON PLAN. <br />CRIPPLE STUDS TO MATCH <br />WALL STUD SIZE, SPACING <br />AND ATTACHMENT TO TOP <br />PLATE. <br />HEADER BEAM. SEE PLAN <br />AND PLAN NOTES. (PLANK <br />INDICATES ROTATED 90 DEG.) <br />MSTA12 AT EACH STUD, <br />U.N.O. ON PLAN. <br />1. PLYWOOD 5HE:ATHING, IF APPLICABLE, 15 NOT 5HQVVN <br />FOR CLARITY. <br />2. A MINIMUM OF (1)JACK AND (2) KING STUDS ARE REQUIRED <br />AT ALL OPENINGS, UNLESS NOTED OTHERWISE ON PLAN. <br />3. WHERE MULTIPLE JAMB STUDS ARE SPECIFIED EACH JAMB <br />STUD IS TO BE STRAPPED WITH MSTA 12. <br />4. NAIL JACK & KING STUDS TOGETHER WITH 10 NAILS AT 8" <br />O.C. STAGGERED EACH SIDE. <br />5. AT WINDOW OPENINGS, PROVIDE 2x SILL PLATE WITH 3-16d <br />TOE NAILS TO EACH JACK. <br />TYPICAL STUD WALL <br />OPENING DETAIL <br />SCALE: NTS <br />STRUCTURAL NOTES <br />These drawings are to be used in combination with job specifications and architectural, mechanical, electrical, plumbing, and site drawings. Consult these drawings for <br />sleeves, depressions, and other details not shown on structural drawings. <br />Do not scale these drawings for dimensions not given. Advise project architect of any conflicts between these drawings and the architectural drawings. Verify all field <br />conditions and confirm column locations in respect to building wall alignment prior to the start of work. All dimensions and conditions must be verified in the field. Any <br />discrepancies shall be brought to the attention of the engineer before proceeding with the affected part of the work. <br />It is the contractor's responsibility to determine erection procedures and sequence to ensure safety of the building and its components during erection. This includes the <br />addition of necessary shoring, sheeting, temporary bracing, guys or tiedowns. <br />The Contractor shall perform no portion of the work at any time without Contract Documents or, where required, approved shop drawings, product data or supplemental <br />details for such portion of the work. <br />The plans show the location of all fixtures & equipment & are intended to convey the general intent of the work in scope & layout. They are not intended to show in <br />minute detail all of the accessories intended for the purpose of execution of the work, but it is understood that such details are part of this work. <br />EXISTING STRUCTURE: <br />Information shown for the existing structure was taken by field inspection and observation by contractor. <br />Work shown on these plans assumes that the original construction was performed in accordance with the standard building code and accepted industry practices at time <br />of construction. It shall be the responsibility of the contractor to verify the conditions relating to the existing structure and to notify the engineer immediately of any <br />discrepancies or conflicts. <br />DESIGN LOADS: <br />The structural system for this building has been designed in accordance with the Florida Building Code, 7th edition (FBC 2020). The following loads have been utilized: <br />Roof: <br />Live Load - 20 Psf. <br />Dead Load - 25 Psf. <br />Handrails and Guards (Loads below need not be applied concurrently): <br />Live Load (Uniform) - 50 Plf. <br />Live Load (Concentrated) - 200 Lbs. (Any Direction/Any Location) <br />Roof Live reductions shall be based on area as outlined in the Florida Building Code. Roof drainage shall conform to the requirements of the Florida Plumbing Code <br />Section 11. <br />Wind load based on using the ASCE 7-16 "Minimum Design Loads and Associated Criteria for Buildings and Other Structures" methods of calculation for wind pressures <br />and the following factors: <br />Ultimate Wind Speed - 137 Mph <br />Allowable Wind Speed - 107 Mph <br />Exposure C <br />Enclosed Structure <br />Risk Factor II <br />This building is NOT IN A WIND BORNE DEBRIS REGION as defined by Florida Building Code. <br />SHOP DRAWING REVIEW: <br />Shop drawings will be reviewed for general compliance with the design intent of the contract documents only. It shall be the responsibility of the contractor to verify <br />compliance with the contract documents as to quantity, length, elevations, dimensions, etc. <br />All shop drawings shall be reviewed by the contractor prior to submittal to the architect/engineer. Drawings submitted without review notation will be returned <br />unchecked. <br />Shop drawings or submittals are required to be (1) electronic copy (combined PDF format) and shall be submitted along with a transmittal. Contractor shall allow for (10) <br />ten business days for shop drawing and submittal review. <br />One set of prints will be retained by the engineer and one by the architect, the contractor shall receive the remaining prints for submittal to the building department and <br />as required for distribution. <br />In all instances the contract documents will govern over the shop drawings unless otherwise specified in a request for information (RFI) or similar documentation by the <br />engineer. <br />Shop drawings should be submitted for all components of the structural framing system, as required by the architect, and as noted elsewhere in these notes, including, <br />but not limited to: <br />Any Alternate Material/Product Substitutions <br />CHEMICAL ANCHORS: <br />Shall be an equal two-part epoxy polymer injection system, such as Simpson Set-XP "Structural Anchoring Adhesive", HILTI HIT-HY 200 MAX or engineer approved <br />substitution, installed in accordance with manufacturer's instructions. Installers shall be trained by the manufacturer's representative. Brush and blow out all holes. The <br />threaded rods to be used in combination with Epoxy system shall be fabricated from steel meeting or exceeding the properties of ASTM A36. <br />MACHINE AND LAG BOLTS: <br />Shall be A307 hot dipped galvanized with galvanized washers. <br />WOOD: <br />Structural wood components (beams, joists, rafters, etc.) Shall have the following minimum allowable fiber stresses for No.2 Southern Pine conforming to NDS, with 2018 <br />supplement, as follows: <br />Shear Fv = 175 Psi. <br />Bending 2x4 Fb = 1,100 Psi. <br />Bending 2x6 Fb = 1,000 Psi. <br />Bending 2x8 Fb = 925 Psi. <br />Bending 2x10 Fb = 800 Psi. <br />Bending 2x12 Fb = 750 Psi. <br />Wood in contact with concrete or masonry, and at other locations as shown on structural drawings, shall be protected or pressure treated in accordance with AITC 109. <br />Member sizes shown are nominal unless noted otherwise. <br />All nails shown on plans assume common wire nails unless specifically noted on drawings. <br />Plywood roof, floor, and wall sheathing are designed as diaphragms and shall comply with applicable provisions of Chapter 23 of The Florida Building Code and shall be <br />fastened in accordance with structural drawings, plan notes and applicable details. Plywood shall be installed with the strength axis of each panel perpendicular to the <br />supports in all cases. Plywood roof panels shall be installed as shown in cases 1 through 4 in FBC Table 2306.2(1). <br />Minimum fastening requirements for built up wood framing, blocking, member connections and plywood sheathing shall not be less than that set forth in FBC Table <br />2304.10.1. Attachment of plywood sheathing to resist wind pressures shall also not be less than what is shown in FBC Table 2304.6.1. <br />MANUFACTURED WOOD STRUCTURAL COMPONENTS: <br />Members designated'LVL' (e.g.,1_3/4 x 14 LVL) shall be laminated veneer lumber as manufactured by Trus Joist Corporation (MicroLam), alpine engineered products (ASI <br />Timbermax LVL), or engineer approved substitution. Fb = 2600 psi, E=1,900,000 psi, Fv = 285 psi. <br />Members designated 'PSL' (e.g., 3Y"x11'/." PSL) shall be Parallam parallel strand lumber as manufactured by Trus Joist Corporation (MicroLam), or engineer approved <br />substitution. Fb = 2900 psi, E = 2,000,000 psi, Fv = 290 psi. <br />Members designated 'APB' (e.g., 3%:"x11%" APB) shall be Anthony Power Beam LSL as manufactured by Anthony Forest Products Comapany, or engineer approved <br />substitution. Fb = 3000 psi, E = 2,100,000 psi, Fv = 290 psi. <br />WOOD FRAMING CONNECTORS: <br />All connectors shall be galvanized. Connector model numbers shown are strong -tie connectors as manufactured by Simpson Strong -Tie Co. Substitutions are acceptable <br />with the approval of the structural engineer. Unless shown otherwise, install size and maximum number of fasteners shown in latest Simpson catalog. <br />WIND ZONES SCHEDULE <br />M1M_ <br />C&C ROOF WIND PRESSURES <br />ZONE <br />TRIBUTARY <br />AREA (SF) <br />POSITIVE <br />PRESSURE (PSF) <br />NEGATIVE <br />PRESSURE (PSF) <br />x 5 20 <br />30.5 <br />75.6 <br />1 <br />20 < x 5 50 <br />23.6 <br />75.6 <br />50 < x 5 100 <br />21.8 <br />46.1 <br />x > 100 <br />18.4 <br />23.6 <br />x 5 20 <br />30.5 <br />75.6 <br />2e <br />20 < x 5 50 <br />23.6 <br />75.6 <br />50 < x 5 100 <br />21.8 <br />46.1 <br />x > 100 <br />18.4 <br />23.6 <br />x 5 20 <br />30.5 <br />110.2 <br />2n <br />20 < x 5 50 <br />23.6 <br />94.6 <br />50 < x 5 100 <br />21.8 <br />75.6 <br />x > 100 <br />18.4 <br />60.0 <br />x 5 20 <br />30.5 <br />110.2 <br />2r <br />20 < x 5 50 <br />23.6 <br />94.6 <br />50 < x 5 100 <br />21.8 <br />75.6 <br />x > 100 <br />18.4 <br />60.0 <br />x 5 20 <br />30.5 <br />110.2 <br />3e <br />20 < x 5 50 <br />23.6 <br />94.6 <br />50 < x <_ 100 <br />21.8 <br />75.6 <br />x > 100 <br />18.4 <br />60.0 <br />x 5 10 <br />30.5 <br />131.1 <br />3r <br />10<x520 <br />23.6 <br />112.0 <br />20 < x 5 50 <br />21.8 <br />87.7 <br />50 < x <_ 100 <br />18.4 <br />68.6 <br />C&C WALL WIND PRESSURES <br />ZONE <br />TRIBUTARY <br />AREA (SF) <br />POSITIVE <br />PRESSURE (PSF) <br />NEGATIVE <br />PRESSURE (PSF) <br />x 5 20 <br />40.9 <br />44.4 <br />20 < x 5 50 <br />39.2 <br />42.6 <br />4 <br />50 < x 5 100 <br />37.4 <br />40.9 <br />x > 100 <br />35.7 <br />39.2 <br />x 5 20 <br />40.9 <br />54.8 <br />5 <br />20<x550 <br />39.2 <br />51.3 <br />50 < x 5 100 <br />37.4 <br />46.1 <br />x > 100 <br />35.7 <br />42.6 <br />NOTES: <br />1. DESIGN CRITERIA: <br />WIND SPEED 137 MPH <br />EXPOSURE CATEGORY C <br />RISK CATEGORY II <br />ENCLOSURE CLASSIFICATION ENCLOSED <br />INTERNAL PRESSURE COEFF. t0.18 <br />ROOF SLOPE 200 < x 5 270 <br />2. ABOVE WIND LOADS ARE ULTIMATE BASED ON ASCE 7-16. WIND LOADS CAN BE <br />CONVERTED TO ASD BY MULTIPLYING BY 0.6. <br />3. POSITIVE PRESSURES INDICATE PRESSURES ACTING TOWARDS A PROJECTED <br />SURFACE. <br />4. NEGATIVE PRESSURES INDICATE PRESSURES ACTING AWAY FROM A PROJECTED <br />SURFACE. <br />5. BUILDING IS NOT IN A WIND-BORNE DEBRIS REGION. <br />FASTENING SCHEDULE PER FBC TABLE 2304.10.1 <br />CONNECTION <br />FASTENING <br />LOCATION <br />TOP PLATE TO STUD <br />2- 16d COMMON <br />END NAIL <br />STUD TO SOLE PLATE <br />4- 8d COMMON <br />2- 16d COMMON <br />TOE NAIL <br />END NAIL <br />DOUBLE STUDS <br />16d AT 24" OC <br />FACE NAIL <br />DOUBLE TOP PLATES <br />DOUBLE TOP PLATES <br />16d AT 16" OC <br />8- 16d COMMON <br />TYPICAL FACE NAIL <br />LAP SPLICE <br />BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE <br />3- 8d COMMON <br />TOE NAIL <br />TOP PLATES, LAPS AND INTERSECTIONS <br />2- 16d COMMON <br />FACE NAIL <br />CONTINUOUS HEADER, TWO PIECES <br />16d COMMON <br />16" OC ALONG EACH EDGE STAGG <br />CEILING JOISTS TO PLATE <br />3- 8d COMMON <br />TOE NAIL <br />CONTINUOUS HEADER TO STUD <br />4- 8d COMMON <br />TOE NAIL <br />BUILT-UP CORNER STUDS <br />16d COMMON <br />24" OC <br />d <br />Z <br />Q <br />Z <br />LU <br />W � O <br />MU)0 <br />I CERTIFY TO THE BEST OF MY <br />KNOWLEDGE THAT THE DRAWINGS AND <br />SPECIFICATIONS COMPLY WITH THE <br />MINIMUM APPLICABLE BUILDING CODES <br />Drawn by: <br />NM <br />Checked by: <br />NM <br />Issue Date: <br />03-15-2021 <br />Project Number: <br />21-004 <br />Revisions: <br />a� <br />0 <br />a. <br />J <br />W <br />O" <br />3 <br />W Lcc",)) <br />WLL <br />�CO W <br />O c'M I <br />W <br />w <br />W N <br />Z <br />u7 <br />1 cMM <br />QU J <br />LL <br />�WW <br />>.Da <br />J = <br />�UU <br />Z C' w C)LO J <br />Wow <br />o. 866 <br />13 <br />c? <br />,,ass' C•S:!�Jz�rL1 �� <br />NICOLAS MENDIETA <br />FL P.E. # 86662 <br />STRUCTURAL NOTES <br />& WIND PRESSURES <br />S001 <br />