Laserfiche WebLink
—•- - —•- �- , , - — - — - — - — - - — - - — - — - — - — - -•-- — - — - - -•— - -•—•- - •- — <br />I.. .. ... .. ... .. .. .. .. ... <br />I.. .. ... .. ... .. .. <br />l I.. <br />EXISTING <br />I CAR WASH' BAY <br />CONCRETE FLOOR ' <br />... ... .. ... .. ... .. ... .. ... .. ... .. .. ... .. ... <br />® : -+- <br />RETENTION AREA _ <br />® TIMER -AT <br />O ; ' PANEL <br />ELECTRICAL NOTES <br />EXTERIOR LIGHT FIXTURES TO BE EXTERIOR <br />WATER PROOF AND TO BE CHOSEN BY OWNER <br />CONNECT ALL NEW ELECTRICAL TO EXISTING <br />SERVICE. EXISTING SERVICE EXCEEDS <br />ELECTRICAL NEEDS <br />EMERGENCY LIGHT IN RESTROOM TO HAVE <br />BATTERY BACK UP <br />ALL OUTLETS TO BE 110 VOLT GROUND FAULT <br />WATER PROOF TO EQUIPMENT OR HARDWIRED <br />TO BE VERIFIED IN FIELD <br />ThMER AT <br />PANEL <br />80 CFM EXI (AUST , ... .. ... .. ... .. ... <br />P0 !rM E <br />FAN VENTED THR'U <br />WALLS ' .. <br />EXISTING' <br />EOUIPMENT ROOM <br />CONCRETE FLOOR•• <br />J EXISTING <br />ELECTRICAL ' .. ' ' ' . <br />�.. 3 8„ PANELS <br />z <br />ELECTRICAL PLAN 1/411 = 1' 0" <br />ELECTRICAL SPECIFICATIONS <br />1.1 SCOPE <br />D. CIRCUIT BREAKERS: Molded case, thermal -magnetic quick -make, quick -break, bolt -on type with <br />A. WORK INCLUDED: Include the following Work in addition to items normally part of this Section: <br />manually operated insulated trip -free handle. Multi -pole types with internal common trip bar. <br />01 Wiring for lighting and power. <br />Terminals suitable for copper or aluminum conductors. Interrupting capacity minimum 10,000 RMS <br />02 Installation of lighting fixtures with lamps. <br />symmetrical amperes circuit breakers to be Square "D" or equal, type as required. <br />03 Lighting panelboards and distribution panelboards. <br />04 Connection of equipment shown. <br />E. PANELB ARD : Voltage, phasing and ampere r tin9s as indicated, circuit breaker type as indicated, ed <br />, <br />05 Control wiring. <br />busbars of hard drawn copper, minimum 98% conductivity, galvanized steel back box, door and trim. <br />06 Disconnection and removal of existing fixtures and wiring not to be reused. <br />All corners lapped and welded, hardware chrome plated with flush lock and catch. Hinges semi- <br />1.2 MINIMUM COMPLIANCE STANDARDS <br />concealed, 5 knuckle steel with nonferrous pins, 180 degree openings, Minimum gutter space 5- <br />A. All work shall be done in accordance with the requirements of the following: <br />3/4" sides, top and bottom. Increase size where required by code, Directory holder complete <br />01 Latest adopted issue of the National Electrical Code, NFPA 70. <br />with clear plastic transparent cover indicating typewritten list of feeder cables, conduit sizes, <br />02 Other applicable NFPA Codes. <br />circuit numbers, outlets of equipment supplied, and their location. Circuit breaker type <br />"D" <br />03 Regulation of local authorities having jurisdiction. <br />panelboards to be Square type NQOD or I -Line, or equal. A plastic label shall be located on exterior of <br />B. Furnish and install all labor, material and equipment and services necessary for complete and <br />an I r identifying he s stem v l h n rr rating. <br />e boa dt voltage, a phase, and current P Y 9, p , 9 <br />safe installation of the electrical system indicated on the drawings and noted in the <br />F. WIRING DEVICES: All devices the product of the same manufacturer. Wall switches single pole, 20 <br />specifications hereinafter. Electrical systems and equipment shall in general include the <br />ampere, 120 volt. Wall switches three-way, 20 ampere, 120 volt. Receptacles duplex, 2 wire; 3 <br />following: <br />pole grounded, 20 ampere, 120 volt. <br />01 General provisions for electrical work. <br />02 Wiring, distribution equipment and devices. <br />G. DEVICE PLATES: Provide for all outlets where devices are installed. Provide engraved marking for <br />03 Lighting fixtures and lamps. <br />special outlets. Provide blank plates for empty or future outlet boxes. DEVICE AND DEVICE PLATES <br />04 Grounding system. <br />COLORS TO BE VERIFIED WITH INTERIOR DESIGNER AND OWNER. <br />1.3 GENERAL PROVISIONS FOR ELECTRICAL WORK <br />1.5 LIGHTING FIXTURES AND LAMPS <br />A. DRAWINGS: Electrical drawings considered diagrammatic and indicate general arrangement of work <br />A. Furnish and install complete system of lighting fixtures, lamps, accessories and supports as <br />and systems. Refer to other drawings to verify location of equipment, etc. Check drawings of <br />specified and indicated. Submittals of equal quality are allowed. <br />other trades to verify exact space condition or underground lines. Drawing Scales prohibit the <br />indication of all offsets, fittings and accessories required, however these items will be <br />1.6 GROUNDING SYSTEM <br />provided by this subcontractor at no extra cost to the owner. <br />A. EQUIPMENT: Ground non -current carrying metal parts of panelboard, raceways and all lighting <br />B. QUALITY OF MATERIALS: New, best of their respective kind, free from defects, and listed by <br />fixtures. All conduits shall have equipment grounding conductors. <br />Underwriter's Laboratories, Inc, or bearing their label. <br />C. SHOP DRAWINGS: Submit four (4) copies of shop drawings for lighting fixtures and panelboards. <br />1.7 INSTALLATION <br />Obtain approval before equipment is ordered, built or installed. <br />A. Secure all supports to building structure. Support horizontal runs <br />D. EXCAVATION AND BACKFILLING: Excavate, backfill and restore surfaces for all electrical work. <br />of metallic conduit not more than 10 feet apart. Run exposed raceways parallel with or at right <br />E. Visit site and inspect existing facilities before bid in order to ensure proper evaluation of <br />angles to walls. <br />working conditions and location of existing equipment. <br />B. Pass raceways over water, steam or other piping when pull boxes are not required. No raceway <br />within 3 inches of steam or hot water pipes, or appliances, except crossings where raceway shall <br />1 A WIRING, DISTRIBUTION EQUIPMENT AND DEVICES <br />be at least 2 inches from pipe cover. <br />A CONDUCTORSC d 'th ASTM St d d f AWG C d N 10 d <br />C C t d 't d th P' t I th d f f Id th d d d 't 'th h't <br />I.. .. .. ... ... ..: .. ... .. .. ... .. <br />I.. <br />I I .. .. .. .. : <br />2X PT LEDGER ATTACHED T F <br />• I I ATTACH 2X8 PT RAFTERS TO LEDGER 8 C O ACE OF BLOCK <br />WITH SIMPSbN,Ll26'HAN0ERS, FILL. WALL WITH 5/8"X5" EXPANSION BOLTS 12" OC <br />I I NAIL HOLES WITH 10DX1 1/2" NAILS : WITH 2" SQUARE WASHERS . <br />.. ... .. ... .. ... .. .. .. .. .. ... .. .. ... .. ... .. ... .. <br />C7 <br />0 <br />Upper, In ac Wl ance WI an ar S, size , erenceS . On MOM O. an U con UI en S square, ream Si7 . aln ma a rea S O le rea a con UI WI grap I e SLOPE FORM TOP OF ALL WALLS TO MATCH RAFTERS <br />smaller size solid, No. 8 and larger stranded. Insulation of conductor thermoplastic, type THHN base pipe compound. Draw up tight with conduit couplings. AND WILL EXTEND TO 1 1/2" BELOW TOP OF RAFTER. PLACE <br />(min. size: No. 12) any wire installed outside, underground, in slabs, or exposed to moisture D. Leave wire sufficiently long to permit making final connections. In raceways over 50 feet in 2X6 PT AT TOP OF WALL SECURED WITH 112"x4" EXPANSION <br />BOLTS 16" OC. ROOF SHEATHING TO NAIL TO BE ATTACHED <br />shall have THWN insulation. which wiring is not installed, furnish pull wire. TO 2X8 WITH 8D NAILS 4" OC <br />B. RACEWAYS: RIGID STEEL CONDUIT, full weight pipe galvanized, threaded, and minimum 1/2 inch except E. Verify locations of outlets and switches. <br />as noted or required for wiring. ELECTRICAL METALLIC TUBING (EMT), thin wall pipe, galvanized, threadless, F. Support panel, junction and pull boxes independently to building structure with no weight bearing <br />comression fittings, and minimum 1/2" except as noted or required for wiring. FLEXIBLE STEEL CONDUIT, on conduits. <br />continuous singlestrip, galvanized, and minimum 1/2" size except as noted or required for wiring. PVC G. Connect conduit to motor conduit terminal boxes with flexible conduit; minimum 18 inches in <br />CONDUIT, heavy duty type, size as indicated. Type AC or MC cable where permitted. Separate raceways shall length and 50% slack. Do not terminate in or fasten raceways to motor foundation. <br />be used for each voltage system. H. Contractor to remove and salvage all abandoned electrical equiment. <br />I. This contractor shall warrant all labor and materials for one year from date of final written <br />C. DISCONNECT SWITCHES: General Duty, horsepower rated for motor loads 600 or 250 volt rating, fused acceptance. <br />or non -fused as noted; number of poles as indicated, cover interlocked with switch. Enclosure <br />NEMA 1 for indoor use and NEMA 3R for weatherproof applications. Switch to be Square "D" or equal. <br />-------- i 1---•—•-----.1.------- -.-..--. ----- ------------:--- —_.—_—:— <br />I I <br />I I.. <br />CARWASHBAY 2X8 PT LEDGER ATTACHED TO FACE OF BLOCK <br />I I CONCRETE L <br />WITH 2 SQUARE WASHERS BOLTS 12 OC <br />FLOOR WALL WITH 5/8"X5" EXPANSION <br />I,1'16" 14' 5" ' V ' ' EXISTING 12' 0" TALL BLOCK WALL : : : ' : : ' : NT <br />.. METAL ROOFING TO MATCH <br />1/2" CDX PLYWOOD NAILED 4" OC TO ALL <br />OVER WITH GAF UNDERLAYME <br />. AND INSTALL <br />ATTACH 2X8 PT RAFTERS TO LEDGER EXISTING BUILDING <br />WITH SIMPSON U26 HANGERS, FILL <br />00 FLOOR DRAIN <br />NAIL HOLES WITH 10DX1 1/2 NAILS <br />- I .. ... .. ... .. ... .. ... . . <br />WITH PRIMER 2" V.T.R. <br />- — - - "-' — 3„ SECURE RAFTERS TO TOP OF WALL WITH <br />o „ „ SIMPSON HETA20 STRAPS POURED IN TOP <br />in I OF WALL, FILL NAIL HOLES WITH 10DX1 1/2" <br />It NAILS <br />Z-, 3„ I FLOOR DRAIN, .. .. EXISTING 2X8 #2 Pj/yE <br />— — _ — — WITH PRIMER EQUIPMENT ROOM, �FTFRs@2a•oc <br />CONCRETE FLOOR <br />. pig 2„ NEW WALL HEIGHT 15' 2" T.B.V. <br />2 SPRUCE C O BOTTOM <br />OF RAFTERS @ 16" OC WITH 2- 10D NAILS <br />• • • • • • INSTALL VINYL UNVENTED SOFFIT AS 2X6 PT FASCIA NAILED TO ENDS <br />CEILING OF RAFTERS WITH 3-12D NAILS <br />1\ N N <br />00 oo <br />SINGLE KNOCK LINTEL BLOCK AT TOP OF <br />3" 3" CLEAN OUT WALL WITH 145 HORIZONTAL REBAR TIED <br />TO ALL VERTICAL RODS AND POURED SOLID <br />TO SEWER SYSTEM WITH 2500 PSI CONCRETE <br />ALL SANITARY PIPING TO BE SCHL 40 PVC <br />SANITARY PLAN 1/4°' = 11011 <br />- I #5 VERTICAL RODS AS SHOWN ON DETAIL <br />S-1 FLOOR AND FOUNDATION PLAN <br />-------- i i---•—•-----.-.— --- <br />-.-.. --- ---------------- —_--- I <br />DECORATIVE CEMENTITIOUS FINISH <br />I I .. „ „ • ON BOTH SIDES OF ALL WALLS <br />I I <br />I I.. <br />EXISTING <br />I I CAR WASH BAY . <br />CONCRETE FLOOR <br />TOP OF SLAB, SEE DETAIL S-1 CONCRETE FLOOR ELEVATION 5' 2" T.B.V. <br />EXISTING ITT' TALL BLOCK WALL <br />1 1 .. ... .. ... .. ... .. ... 1 <br />i <br />1 i <br />1 i <br />.. .. ... .. .. 1 <br />. 1 <br />EXISTING RETAINING WALL <br />I � � <br />E DETAIL 1 ' S ILS- ---, <br />i <br />3/4" : 3/4" : .EXISTING <br />EQUIPMENT ROOM <br />1 I CONCRETE FLOOR <br />- - RETENTION POND ELEVATION 01011 <br />HOT.WATER LINE.T.O CONNECT, <br />TO EXISTING WATER HEATER BUILDING CUT SECTION DETAIL <br />3l4" VERIFY CONNECTION INFIELD <br />3/!� ' <br />NOT TO SCALE <br />3/4" SOV <br />FROM METER <br />3/4" <br />ALL WATER PIPING TO BE CPVC OR EQUAL <br />WATER LINE PLAN 1 /411 = 11 0" <br />2X8 4V PINE %AfI1 ERS fl-) 24" <br />24' <br />r <br />I I ;!I I I♦♦♦ <br />I J♦� <br />I - <br />I i�♦� <br />I I �',') i i v♦� <br />I I I" I ',I I I u♦i <br />I I I,❑ �'I I �♦i ] J I ♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦ ♦♦♦, <br />' �ti. �wwww�.�w�ww�.wwwwwwwi <br />FORM AND POUR 8" BOND BEAM AT TOP OF <br />WALL WITH 145 REBAR TIED TO VERTICAL <br />Rnnc <br />I <br />® r <br />a•°r <br />••�i . r0 r . '. • '.. <br />':. • ':.sp <br />'.• .• .• • •°r4. <br />s i <br />I <br />)\,-N <br />I <br />I <br />I <br />I <br />SLOPED WALL CUT SECTION DETAIL <br />NOT TO SCALE <br />ARKAY ENGINEERING INC. <br />STRUCTURAL ENGINEERS <br />RICHARD L. KIDDEY P.E. <br />FLORIDA LICENSE NUMBER 37296 <br />E <br />U <br />N <br />N <br />z <br />L" <br />co <br />C`7 <br />1.0 <br />nJ <br />O <br />z <br />� <br />Z <br />UCD <br />W N <br />❑ N <br />\~ <br />1 <br />� <br />(5 <br />W <br />00N <br />W <br />Cn <br />A <br />Z <br />— <br />m <br />Q W <br />o_ <br /><= LL <br />m u- <br />LL <br />lY <br />❑ <br />000 <br />7- <br />Zi <br />® <br />N <br />w <br />Cn <br />r- <br />to l�i <br />m <br />m <br />m <br />m�0Q3 <br />z <br />mWtou <br />X L� <br />— <br />Iiom <br />t3 Y <br />J L <br />Z16— o <br />o� <br />W Mm <br />Z v3 <br />X to <br />O W V <br />1 � <br />fll 0 <br />I U Q3 <br />20 <br />a. N QL <br />tii <br />H <br />Q <br />Z <br />O <br />En <br />W <br />IY <br />III- <br />00 <br />CU <br />f <br />Z <br />o <br />W <br />a <br />O <br />Z <br />00 <br />O <br />J <br />J � <br />17 <br />I.L.. <br />O <br />2 LL <br />I,.LI <br />N J <br />= J <br />U) _ <br />< <br />U <br />N <br />Zr <br />C) <br />W C'7 <br />J >_ <br />U� <br />N <br />W <br />CA <br />I HERBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS <br />WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION <br />ARE IN COMPLIANCE WITH CHAPTER 16, SECTION 1609 OF THE <br />FLORIDA BUILDING CODE 2020 7 TH EDITION AND ASCE 7-16 <br />FOR 139 MPH WIND ZONE RISK CATEGORY II <br />ARKAY #19726 <br />