My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5939 12th St
Zephyrhills
>
Building Department
>
Building Plans
>
5939 12th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:05:53 AM
Creation date
2/19/2025 12:49:08 PM
Metadata
Fields
Template:
Building Plans
Street #
5939
Location
12th St
Contractor
Point West Construction
Building Plans - Permit #
1143
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL KEY <br />i <br />MA <br />GFI - HOME RUN OUTLET IN GARAGE <br />Q� <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />Gn <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />q? <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />F <br />DUPLEX OUTLET IN FLOOR <br />jr220 <br />0 <br />VOLT OUTLET <br />0 <br />uc <br />UNDER CABINET" OUTLET <br />PLNT <br />E <br />DUPLEX OUTLET ON PLANT LEDGE <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />NO <br />RHEOSTAT SWITCH <br />tiEY <br />KEY SWITCH <br />CEILING MOUNTED INCANDESCENT LIGHT FIXTURE <br />V <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />RECESSED INCANDESCENT LIGHT FIXTURE <br />® <br />LIGHT FIXTURE WITH PULL CHAIN <br />®CEILING <br />F <br />MOUNTED INCANDESCENT LIGHT <br />FIXTURE W/ ROUGH -IN FOR OPT. CEILING FAN <br />® <br />RECESSED EYE BALL FIXTURE <br />VoTm <br />HOLLYWOOD STRIP LIGHT <br />® <br />VAPOR PROOF LIGHT FIXTURE <br />C} <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/UGHT COMBINATION <br />® <br />OUTLET FOR GARAGE DOOR OPENER <br />® <br />CHIMES (OPTIONAL) <br />f • 1 <br />PUSHBUTTON SWITCH <br />COMBINATION SMOKE/CARBON MONOXIDE ALARM <br />rMN <br />TELEPHONE <br />® <br />TELEVISION <br />® <br />A/C THERMOSTAT CONTROLS <br />® <br />VENTILATOR CONTROLS <br />ELECTRIC METER <br />�o <br />® <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER <br />© <br />REINFORCED JUNCTION BOX <br />BELL <br />BELL <br />® <br />FIBER OPTICS OUTLET <br />SOFFIT MNT. FLOOD LIGHT <br />INMR <br />com <br />INTER-COM <br />® <br />SECURITY SYSTEM KEYPAD <br />o <br />CEILING MNT FAN <br />p17 <br />CEILING MNT FAN/LIGHT <br />ELECTRICAL LOAD CAL. <br />(NATIONAL ELECTRICAL CODE EXAMPLE NO. 1(b)) <br />JOB NAME: <br />LOT NO: <br />1,555 SQFT @ 3 WATTS 4.97 KW <br />TWO 20-1 AMP APPLIANCE @ 1500 WATTS 3.00 KW <br />LAUNDRY CIRCUIT 1.50 KW <br />RANGE 12.00 KW <br />WATER HEATER 2.50 KW <br />DISHWASHER 1.20 KW <br />HEAT 9.00 KW <br />DRYER 5.00 KW <br />TOTAL 39.17 KW <br />FIRST 10 KW @ 100% = 10.00 KW <br />REMAINING @ 40% (29.17 x 0.40) = 11.67 KW <br />CALCULATED LOAD FOR SERVICE SIZE = 21.67 KW <br />21666 WATTS DIVIDED BY 240V = 90.28 AMPS <br />NOTES: <br />ALL ELECTRICAL TO COMPLY WITH `NATIONAL ELECTRICAL CODE <br />2014 EDITION <br />1. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORS AS REQUIRED BY <br />NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AND MEETING THE REQUIREMENTS <br />OF ALL GOVERNING CODES <br />2. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS (GFI) AS REQUIRED BY <br />NATIONAL ELECTRIC CODE (NEC) AND MEETING THE REQUIREMENTS OF ALL GOVERNING <br />CODES <br />3. MASTER BATH STANDARD 36" HIGH VANITY, OUTLET TO BE 4" ABOVE VANITY TOP <br />4. ELECTRICAL CONTRACTOR TO PROVIDE REQUIRED DIRECT HOOK-UPS/CUTOFFS <br />5. HVAC CONTRACTOR TO VERIFY THERMOSTAT LOCATIONS <br />6. ALL ELECTRICAL AND MECHANICAL EQUIPMENT (I.E. FURNACES, A/C UNITS, <br />ELECTRICAL PANELS, SANITARY SUMP PITS, DRAIN TILE SUMP AND WATER HEATERS) ARE <br />SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS <br />7. ELECTRICAL SMOKE DETECTORS TO BE IN COMPLIANCE WITH LOCAL BUILDING CODES <br />8. ALL SMOKE DETECTORS SHALL BE 110V INTERCONNECTED <br />9. ALL NON-GFCI OUTLETS ARE TO BE AFCI AND TAMPERED RESISTANT OUTLETS <br />APPROVED METER SOCKET <br />POWER CO. SUPPLIED METER <br />2 1 /2" EC FROM METER CAN TO <br />18" BELOW GRADE FOR SERVICE <br />ENTRY, PER POWER COMPANY <br />REQUIREMENTS. <br />APPROVED 200 AMP, 120/240 VOLT <br />3 WIRE DISTRIBUTION PANEL... <br />Dm <br />2" EMT <br /># 4 THW CU. TO 3/4" C.W. PIPE & TO <br />5/8" REBAR DRIVEN TO A MINIMUM <br />DEPTH OF 9'-0" BELOW GRADE... <br />3/4" C.W. LINE <br />CLAMP <br />5/8" REBAR FASTEN TO SLAB <br />REINFORCING AND RUN HORIZONTAL <br />UNDER GRADE <br />ELECTRICAL SERVICE SCHEMATIC 200 <br />AMP SERVICE <br />DUPLEX OUTLET AND <br />SWITCHES OVER <br />VANITY COUNTERTOPS <br />OPTIONAL BACK <br />SPLASH MOUNTING OF <br />DUPLEX OUTLET � a <br />FINISH FLOOR <br />AND SWITCHES OVER <br />KITCHEN COUNTERTOPS <br />BACK SPLASH <br />REFRIGERATOR <br />OUTLET <br />LL <br />a <br />It00 <br />LL. <br />a <br />z <br />o <br />_ <br />in <br />-d- <br />LIGHT SWITCH <br />DUPLEX OUTLET <br />TELEPHONE / <br />TELEVISION <br />= e JACK <br />BASE BOARD <br />THESE PLANS ARE THE PROPERTY <br />a 145 VERTICAL <br />WHILE THESE PLANS HAVE BEEN <br />OF THE NAMED OWNER, ANY <br />C IN PILLE ELL <br />CHECKED FOR ACCURACY, IT IS THE <br />REPRODUCTION WITHOUT WRITTEN <br />245 VERTICALS <br />BUILDERS RESPONSIBILITY TO VERIFY <br />AUTHORITY IS EXPRESSLY <br />IN FILLED CELL <br />ALL DIMENSIONS IN THE FIELD... <br />FORBIDDEN, AND MAY RESULT IN <br />�.� <br />DO NOT SCALE THESE PLANS <br />COPYRIGHT INFRINGEMENTS. <br />SHEAR MDnPJPNT <br />DATE <br />Oct 7, 2020 <br />Q <br />QI=—s <br />w 3 cozaWW <br />-v-)Zo z <br />� © < uj <br />uj <br />d � N <br />C+ m <br />�U� .� <br />�c <br />w¢Zo <br />C)wuj mo� <br />LaP- <br />o:: o <br />W I U- <br />zaw w <br />—�Z� <br />h <br />_IJ.:a <br />o:_ <br />SHEET <br />-' 6Bx SCALE -`- <br />GCF 1/4" = 1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.