Laserfiche WebLink
EXISTING 4" GREASE <br />PIPING. VERIFY SIZE AND <br />LOCATION IN FIELD <br />I�t�■1 <br />iMIN <br />milisi <br />-J" <br />TIE INTO EXISTING <br />SANITARY WASTE. <br />(NEW) PANEL "AP-4" <br />SQUARE D, 208/120VAC, 3PH, 4W, 225A MAIN LUGS ONLY <br />DESCRIPTION <br />VOLT/ <br />AMPS <br />POLE/ <br />AMPS <br />WIRE & <br />CONDUIT <br />PH <br />POLE/ <br />AMPS <br />WIRE & <br />CONDUIT <br />VOLT/ <br />AMPS <br />DESCRIPTION <br />1 <br />REFRIG. -BOTTLE BEVERAGE <br />1,440 <br />1f20 <br />2#12, #12G, 1/2"C. <br />A <br />1/20 <br />2#12, #12G, 1/2"C. <br />360 <br />LIGHT BOX <br />2 <br />3 <br />REFRIG. - WORKTOP 27" WIDE W/ SIR <br />480 <br />1/20 <br />2#12, #12G, 1/2"C. <br />B <br />1/20 <br />2#12, #12G, 1/2"C. <br />1,200 <br />DUAL JUICE DISPENSER <br />4 <br />5 <br />REFRIG.- BOTTLE BEVERAGE W/ STAND <br />1,440 <br />1/20 <br />2#12,#12G,1/2"C. <br />C <br />1120 <br />2#12,#12G,1/2"C. <br />792 <br />FULL HEIGHT REFRIGERATOR <br />6 <br />7 <br />SPARE <br />1/20 <br />A <br />2130 <br />3-#10,#10G3/4"C <br />2,496 <br />SPECIALTYCOFFEE <br />8 <br />9 <br />SPARE <br />1f20 <br />B <br />I ----- <br />---- ---- <br />2,496 <br />1 --------- <br />10 <br />11 <br />SMOOTHIE MACHINE <br />2,400 <br />1/20 <br />2#12, #12G,1/2"C. <br />C <br />SPACE <br />12 <br />13 <br />SPACE <br />A <br />SPACE <br />14 <br />15 <br />SPACE <br />B <br />SPACE <br />16 <br />17 <br />SPARE <br />I <br />CI <br />SPACE <br />18 <br />19 <br />SPACE <br />A <br />SPACE <br />20 <br />21 <br />SPACE <br />B <br />SPACE <br />22 <br />23 <br />SPACE <br />C <br />SPACE <br />24 <br />25 <br />SPACE <br />A <br />SPACE <br />26 <br />27 <br />SPACE <br />B <br />SPACE <br />2$ <br />29 <br />SPACE <br />C <br />SPACE <br />30 <br />31 <br />SPACE <br />A <br />SPACE <br />32 <br />33 <br />SPACE <br />B <br />SPACE <br />34 <br />35 <br />SPACE <br />C <br />SPACE <br />36 <br />37 <br />SPACE <br />AlSPACE <br />38 <br />39 <br />SPACE <br />B <br />SPACE <br />40 <br />41 <br />SPACE <br />C <br />I <br />i <br />SPACE <br />42 <br />VA AMPS TOTAL CONN. VA= 13,104 <br />PHASE A = 4,296 36 TOTAL DEMAND VA= 13,104 <br />PHASE B = 4,176 35 25% CONT. LOAD VA= 90 25% LARGEST MOTOR VA = 600 <br />PHASE C = 4,632 39 <br />TOTAL CALC. AMPS = 38 <br />9G0.89 — PC TO VENT THROUGH <br />I` <br />PLUMBING/POWER PLAN <br />SCALE: 1 /4"=1'-0" <br />KEYED NOTES <br />01 EXISTING 800A, 208/120V, 3PH, 4W, POWER PANEL "PP" W/ 800A <br />MAIN BREAKER TO REMAIN. <br />O2 EXISTING CABINET W/ PANELS "AP-1", "AP-2" & "AP-3" TO REMAIN. <br />O EC TO PROVIDE & INSTALL A NEW 3P/200A CIRCUIT BREAKER IN <br />SPACE SHOWN FOR PROVIDING FEEDER POWER TO NEW PANEL "AP-4". <br />AIC RATING SHALL MATCH EXISTING. <br />® NEW 4-#3/0 & #6 GND. 2"C. <br />O5 EC TO PROVIDE & INSTALL NEW 225A, 42 CKT, 208/12OV, 3PH, 4W, <br />MLO CIRCUIT BREAKER PANELBOARD. PROVIDE & INSTALL NEW BOLT -IN <br />TYPE BRANCH CIRCUIT BREAKERS PER PANEL SCHEDULE THIS SHEET. <br />CKT BRKR AIC RATINGS SHALL MATCH EXISTING. <br />© RELOCATED HAND SINK. PC TO ROUTE Y2" HOT & COLD WATER <br />SUPPLY LINES FROM EXISTING WATER SUPPLY LINES AND CONNECT TO <br />HAND SINK. PC TO ROUTE 1Y2" DRAIN LINE FROM SINK AND CONNECT <br />TO EXISTING SANITARY WASTE. <br />O EC TO MAINTAIN WORKSPACE AS SHOWN. <br />LOAD SUMMARY <br />30, 4W, 208 120VAC <br />DESCRIPTION <br />LOAD VA <br />PEAK DEMAND <br />148,000 VA <br />25% PEAK DEMAND <br />37,000 VA <br />NEW LOADS <br />13,104 VA <br />25% OF NEW CONT. LOADS <br />90 VA <br />25% OF NEW CONDENSER LOADS <br />600 VA <br />TOTAL NEC CALCULATED LOAD <br />198,104 VA <br />TOTAL NEC CALCULATED AMPS <br />550 AMPS <br />EXISTING SERVICE SIZE <br />800 AMPS <br />NOTE: <br />THE EXISTING -AND NEW PANELS ARE ADEQUATELY SIZED <br />TO HANDLE THE EXISTING AND NEW LOADS. <br />PARTIAL RISER DIAGRAM <br />NOTES: <br />POS NOTES <br />1. POS SYSTEM TO BE EVALUATED AND REDESIGNED AS REQUIRED BY <br />POS PROVIDER. <br />ELECTRICAL NOTES <br />1. ALL ELECTRICAL PANEL CIRCUITS TO BE VERIFIED BY ELECTRICAL <br />CONTRACTOR. <br />2. PANEL CIRCUIT DESIGNATIONS SHOWN ON ELECTRICAL SCHEDULE <br />ARE APPROXIMATE. <br />3. EC TO VERIFY THAT NEW OR MODIFIED CIRCUITS PER THIS SCOPE <br />TO BE PROTECTED VIA "GFCI" TYPE CIRCUIT BREAKERS IN <br />COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE [210.8 (B)(2)] <br />4. FOR THE EXISTING EQUIPMENT THAT IS BEING RELOCATED, THE EC <br />IS TO IDENTIFY & VERIFY THE EXISTING CIRCUITS AND EXTEND TO <br />THE NEW LOCATION OF THE EXISTING EQUIPMENT. <br />5. EC TO COORDINATE W/ LOCAL UTILITY COMPANY TO VERIFY THAT <br />THE EXISTING TRANSFORMER IS OF ADEQUATE SIZE. <br />6. MC CABLE IS AN ACCEPTABLE WIRING METHOD. <br />PLUMBING NOTES <br />1. PC TO TRENCH NEW DRAINS PER AUTHORITY HAVING JURISDICTION. <br />2. COFFEE WATER TO ORIGINATE FROM R.O. SYSTEM LOCATED IN REAR <br />OF RESTAURANT. <br />LEGEND/ABBREVIATIONS: <br />ZIQ - 20A, 125V, 3W, GROUNDING TYPE DUPLEX RECEPTACLE <br />FS - DENOTES FLOOR SINK <br />FD - DENOTES FLOOR DRAIN <br />PC - PLUMBING CONTRACTOR <br />EC - ELECTRICAL CONTRACTOR <br />AFF - ABOVE FINISHED FLOOR <br />DN - DOWN <br />CKT - CIRCUIT <br />BRKR - BREAKER <br />PROVIDE TRAP PRIMERS FOR NEW <br />FLOOR DRAINS AS REQUIRED. <br />THE FLOOR DRAIN SHALL MEET <br />THE REQUIREMENTS OF THE FLA. <br />BUILDING CODE PLUMBING 2004. <br />CONNECT NEW WASTE LINE <br />NOTE: CONTRACTOR TO VERIFY AS -BUILT <br />TO EXIST. GREASE LINE <br />CONDITIONS DO NOT CONFLICT W/ <br />3" <br />PROPOSED DIAGRAM. <br />3" VERIFY <br />NOTE: CONTRACTOR TO VERIFY PLUMBING <br />REQUIREMENTS W/ EQUIPMENT SUPPLIER. <br />GREASE <br />2 RISER DIAGRAM <br />E1.0 SCALE: N.T.S. <br />PB=Pullbox NF=VmlfylnFlald <br />PB = Junction Box ELECTRICAL SCHEDULE <br />EC = Electrical Contractor <br />TAG # <br />QTY <br />DESCRIPTION <br />VOLT / PH <br />FLA <br />BRK SIZE <br />COND / WIRE <br />PNL / CCT <br />RECEP TYPE <br />HGT AFF <br />REQUIREMENTS & REMARKS <br />179.09E1 <br />1 <br />REFRIGERATOR - BOTTLE BEVERAGE REF'R <br />120/1 <br />12.0 <br />20A <br />1/2"C-2#12 <br />AP4-3 <br />5-20R <br />2'-0" <br />REFERENCE PANEL SCHEDULE THIS SHEET <br />179.11El <br />1 <br />REFRIGERATOR - WORKTOP 27" WIDE W/ SYRUP RAIL <br />120/1 <br />4.0 <br />20A <br />1/2"C-2#12 <br />AP4-1 <br />5-20R <br />2'-0" <br />REFERENCE PANEL SCHEDULE THIS SHEET <br />21.1OE1 <br />1 <br />SPECIALTY COFFEE <br />208/1 <br />24 <br />30A <br />3/4"C-2#10 <br />AP4-5,7 <br />L6-30R <br />2'-3" <br />REFERENCE PANEL SCHEDULE THIS SHEET <br />21.5OE1 <br />1 <br />SMOOTHIE MACHINE <br />120/1 <br />20 <br />20A <br />1/2"C-2#12 <br />AP4-3 <br />5-20R <br />2'-3" <br />REFERENCE PANEL SCHEDULE THIS SHEET <br />24.01E2 <br />1 <br />DUAL JUICE DISPENSER <br />120/1 <br />10 <br />20A <br />1/2"C-2#12 <br />AP4-E <br />5-20R <br />2'-3" <br />REFERENCE PANEL SCHEDULE THIS SHEET <br />47.08E1 <br />1 <br />IFULL HEIGHT REFRIGERATOR <br />120/1 <br />6.6 <br />20A <br />1/2"C-2#12 <br />AP4-14 <br />5-20R <br />2'-0" <br />REFERENCE PANEL SCHEDULE THIS SHEET <br />9.1OE1 <br />1 <br />UTILITY CHASE - D/T PRESENTERS BOOTH <br />S R KS <br />SEE RMKS <br />SEE RMKS <br />SEE RMKS <br />------ <br />SEE RMKS <br />SEE RMKS <br />EC TO BRING INDIV CIRCUITS TO TERMINAL BLOCK INSIDE CHASE <br />900.13E1 <br />1 <br />RELOCATED AUTOMATED BEVERAGE SYSTEM <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />ISTING BRANCH CIRCU <br />RELOCATED <br />AS EXISTING <br />EC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />900.23E1 <br />5 <br />RELOCATED DT POS SYSTEM <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />ISTING BRANCH CIRCU <br />RELOCATED <br />AS EXISTING <br />EC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />900.24E1 <br />3 <br />RELOCATED/REDESIGNED FC POS SYSTEM <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />ISTING BRANCH CIRCUI <br />RELOCATED <br />AS EXISTING <br />EC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />900.52E2 <br />1 <br />RELOCATED UNDERCOUNTER REFRIGERATOR <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />ISTING BRANCH CIRCUI <br />[EXISTING <br />RELOCATED <br />AS EXISTING <br />EC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />900.55E21 <br />RELOCATED CREAM DISPENSER <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />BRANCH CIRCUIT <br />RELOCATED <br />AS EXISTING <br />EC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />900.57E2 <br />1 <br />RELOCATED COFFEE BREWER <br />EXISTING <br />EXISTING <br />I EXISTING <br />I EXISTING <br />ISTING BRANCH CIRCUIT <br />RELOCATED <br />I AS EXISTING <br />I EC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />900.59E2 <br />1 <br />RELOCATED ORANGE JUICE DISPENSER <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />ISTING BRANCH CIRCUIT <br />RELOCATED <br />AS EXISTING <br />I EC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />900.99E1 <br />1 <br />RELOCATED ICE MACHINE <br />EXISTING <br />I EXISTING <br />I EXISTING I <br />EXISTING <br />1EXISTING BRANCH CIRCUIT <br />RELOCATED <br />JAS EXISTING <br />JEC TO RECONNECT TO EXISTING BRANCH CIRCUIT <br />Field PLUMBING SCHEDULE <br />PC = Plumbing <br />PC = Plumbing Cantractw <br />TAG # <br />QTY <br />DESCRIPTION <br />HW <br />CW <br />MISC-PLBG <br />HGT-AFF <br />DRAIN <br />REQUIREMENTS & REMARKS <br />201.16P1 <br />1 <br />DRIVE-THRU ABS TABLE - 39" W <br />- <br />- <br />_ <br />- <br />1" DRAIN <br />PC TO CONNECT DRAIN LINE TO FLOOR DRAIN <br />21.1OP1 <br />1 <br />SPECIALTY COFFEE MACHINE <br />- <br />- <br />3/8' FILTERED <br />SEE RMKS <br />- <br />C TO CONNECT THROUGH WATER TREATMENT (IF REQUIRED) <br />21.1OP2 <br />11 <br />SPECIALTY COFFEE MACHINE <br />- <br />- <br />- <br />- <br />3/4" DRAIN <br />DC TO CONNECT DRAIN LINE TO EXISTING DRAIN <br />21.50P1 <br />1 <br />SMOOTHIE MACHINE <br />- <br />- <br />3/8" <br />- <br />3/8" DRAIN <br />C TO CONNECT WATER LINE AND DRAIN <br />1.5OP2 <br />1 <br />SMOOTHIE MACHINE <br />- <br />- <br />CO2 LINE <br />3C TO CONNECT CO2 LINE <br />4.01P2 <br />1 <br />DUAL JUICE DISPENSER <br />- <br />- <br />1/2" FILTERED <br />SEE RMKS <br />- <br />DN CHASE FROM BEVERAGE SYSTEM <br />5.5OP1 <br />1 <br />BEVERAGE CABINET -DRIVE-THRU - 63 W ICE BIN, <br />- <br />- <br />_ <br />- <br />1" DRAIN <br />PC TO CONNECT DRAIN LINE TO FLOOR DRAIN <br />01.17P1 <br />1 <br />3" FLOOR SINK - FULL GRATE <br />- <br />- <br />2" VENT <br />- <br />DRAIN <br />W <br />CONNECT TO EXISTING PIPING <br />01.10P1 <br />2 <br />3" FLOOR DRAIN WITH FUNNEL <br />- <br />- <br />2" VENT <br />- <br />3" DRAIN <br />CONNECT TO EXISTING PIPING <br />900.13P1 <br />1 <br />RELOCATED AUTOMATED BEVERAGE SYSTEM <br />- <br />- <br />- <br />- <br />FD W/FUNNEL <br />- <br />900.13P2 <br />1 <br />RELOCATED AUTOMATED BEVERAGE SYSTEM <br />- <br />- <br />6" PVC CONDUIT <br />SEE RMKS <br />- <br />ABOVE CEILING FROM SODA SYSTEM - TERMINATE AT CHASE <br />900.13P3 <br />1 <br />RELOCATED AUTOMATED BEVERAGE SYSTEM <br />- <br />- <br />6" DRINK COND. <br />SEE RMKS <br />- <br />DN CHASE FROM SODA SYSTEM - "T" FROM D/T IF <br />REQUIRED - BEV. INSTALLER TO MAKE FINAL CONNECTIONS, <br />LOCAL CODES PERMITTI <br />00.57P2 <br />1 <br />RELOCATED COFFEE BREWER <br />3C TO REWORK ALL EXISTING UTILITIES AS REQUIRED <br />900.59P2 <br />1 <br />RELOCATED ORANGE JUICE DISPENSER <br />- <br />- <br />- <br />- <br />- <br />C TO REWORK ALL EXISTING UTILITIES AS REQUIRED. <br />00.89131 <br />1 <br />RELOCATED HAND SINK <br />- <br />- <br />- <br />- <br />- <br />-MUUNI <br />900.99Pi <br />1 <br />RELOCATED ICE MACHINE <br />- <br />- <br />- <br />- <br />- <br />PC TO REWORK ALL EXISTING UTILITIES AS REQUIRED. <br />n <br />ALL WORK SHALL CONFORM WITH THE <br />LATEST ADOPTED EDITIONS OF THE 2004 <br />FLORIDA BUILDING CODE INCLUDING <br />ACCESSIBILITY, OTHER APPLICABLE <br />CODES 2006 AND 2007 SUPPLEMENTS <br />SUOISiAGN <br />W <br />a <br />U) <br />Q <br />04(1 <br />Z .> OC' <br />co � <br />LL <br />Oct <br />MJN <br />;aJ <br />Va Oal <br />0 W <br />a coNi <br />z <br />O <br />V <br />0 06 <br />0 o0 <br />Lo w I <br />T- ~O M <br />o <br />W <br />w <br />ITN <br />z r - pry <br />no >rM <br />¢M I or- <br />LO � � <br />0 <br />o_J0000 6 <br />z <br />M <br />O Opp�m <br />�-00 w <br />Lo�ZX.J <br />oQ O04 <br />�� <br />Lo a <br />U <br />z <br />n: <br />�X0 <br />z <br />w <br />0 <br />a <br />IN O <br />pa <br />ON <br />wPQ <br />Z <br />0 4) <br />0~ <br />Am opo <br />rA F-4 <br />W <br />RALF D. PORSCH. P.E. \ <br />FL REG. N0. 411 <br />/7 <br />THE DESIGN INDICATED IN THESE <br />CONSTRUCTION DOCUMENTS DOES TO <br />THE BEST OF MY KNOWLEDGE, <br />FORMATION, AND BELIEF COMPLY WIT <br />THE APPLICABLE MINIMUM BUILDING <br />CODES <br />r:Sheelt Numbeer <br />EloO <br />