My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6052 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6052 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:13:15 AM
Creation date
2/19/2025 12:54:00 PM
Metadata
Fields
Template:
Building Plans
Street #
6502
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18699
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 --/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Dipper to lights 8 outlets <br />3pper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />I Alu <br />------ ---- ---J <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.FJ. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />>a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />�7 <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />TL <br />2" <br />WM. <br />pl, <br />1 2" VTR I <br />I I <br />I � <br />rrn <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />KITCHEN <br />LAV, <br />SWITCH FOR <br />DISPOSAL IN CAB. <br />WPTn <br />O KUUUM-IN <br />FOR OPT. <br />2x4 FL.FAN/LIGHT <br />1'-- 15 <br />OPTIONAL LIGHTING <br />SCALE. %4'"=1'-0" <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />IRRIGATION GFI <br />@ 44" A.F.F. <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />1st FLOOR ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />Lu <br />U) <br />Z o <br />— CO <br />Z <br />Q <br />O <br />Z <br />Qj <br />L/) V <br />n <br />W V) <br />4--J L11 <br />•U <br />%C <br />L u <br />O <br />F— <br />r <br />O <br />_OO <br />U <br />m^ <br />a)M <br />WC <br />mmok F_ E <br />— 3 <br />W C0 <br />12m m <br />N <br />080 <br />U N <br />rCD LL00 <br />0Yr` <br />C-_ <br />Q rn <br />O d <br />rn .V! <br />A1 <br />8 D® <br />N.C.B.D.0 <br />V <br />ti <br />C <br />N <br />N_ <br />N <br />.0 <br />N <br />W <br />G 000 <br />�ZQQ867 <br />dMrn= Ln <br />F 5 IL 0 O <br />L. Z <br />LL <br />N <br />W aO�a <br />° a <br />Z V �a <br />_N�oC,? <br />0 z <br />rz <br />Z;� <br />LLW< <br />mm <br />N <br />N a M <br />o <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />n <br />0 <br />CD <br />Ul <br />Z <br />(nMp <br />M <br />a�MLn <br />a vt�L� <br />0 Ln <br />LL <br />d ^ <br />�6a00 <br />U�0 <br />Q � <br />Z <br />W <br />Jo� <br />�O <br />J <br />f <br />Z <br />0-- <br />�LLJ Li- <br />W m �''" <br />W 2W <br />C <br />UI—tn00 <br />�0 ZQU <br />zQaoUQZ <br />Z x�tZuF-Z <br />C7 Z p o. W <br />W <br />g� <br />O S 00 LU <br />rl <br />M <br />I— Se <br />0 z© <br />O <br />r—i <br />Ln <br />N <br />Ln <br />.. <br />�00a <br />oc <br />^Z <br />Wobe <br />od <br />O <br />Q Q <br />�M-, <br />z <br />J <br />(9' s =) 0 <br />W£VC6 <br />cn <br />rl U\I <br />Q0. <br />a�o8 <br />cog fl� 0 <br />o <br />M U <br />f <br />a�LL <br />LL <br />W <br />z W <br />J <br />Z <br />OJ <br />g W <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />1122 <br />JOB NO: 17-2861 <br />SHEET NO. <br />5 <br />- - <br />_...— -�T i is ai ni �,m uti dti�u. uu wh raa�m�s� Y>H, 11i1 , �..�f n .a.r li li ft.I: <br />
The URL can be used to link to this page
Your browser does not support the video tag.