Laserfiche WebLink
ENGINEER'S WITES: <br />1, <br />DESIGN WIND SPEED: 140 MPH VUtt/ <br />108 MPH Vsd, 3 sec gust <br />2, <br />RISK CATEGORY PER Table 1604,5 <br />II <br />3, <br />EXPOSURE CATEGORY - "B" <br />4, <br />INTERNAL PRESSURE C❑EFFICIENT = <br />+/- 0,18 (ENCLOSED BLDG) <br />5, <br />COMPONENTS & CLADDING DESIGN <br />PRESSURES PER ASCE 7-10 <br />(ROOF) <br />ZONE 1b: +12/-20 <br />ZONE 2a; +13/-35 <br />ZONE 3a: +13/-52 <br />(WALLS) <br />ZONE 41o; +21/-23 <br />ZONE 5b +21/-28 <br />CJDES <br />FLORIDA RESIDENTIAL CODE) FLORIDA BUILDING CODE) GTH EDITI❑N 2017 <br />ASCE 7 10 <br />C❑NSTRUCTI❑N TYPE: 5-B <br />BUILDING CODE REQUIREMENTS FOR REINS❑RCED CONCRETE (ACI 318-11) <br />SPECIFICATI❑NS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STURCTURES (ACI 530-11) <br />NATI❑NAL DESIGN SPECIFICATI❑NS FOR WOOD C❑NSTRUCTI❑N, LATEST EDITI❑N <br />APA PLYWOOD DESIGN SPECIF-ICATI❑N <br />GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL PERFORM THEIR WORK IN <br />ACCORDANCE WITH ALL APPLICABLE CODES G❑VERNING EACH TRADE, <br />GENERAL N❑TES: <br />WIND❑W AND DOOR MANUFACTURERS TO PR❑VIDE CERTIEICATI❑N/RATING THAT THEIR WIND❑WS AND DOORS <br />WILL WITHSTAND THE PRESSURE RESULTING FROM THE SPECIFIED DESIGN COMPONENTS AND CLADDING WIND <br />' PRESSURE AND PR❑VIDE INSTALLATI❑N INF❑RMATI❑N WITH THEIR PRODUCTS, <br />T CONTRACTOR TO INSTALL WIND❑WS AND DOORS ACC❑RDING TO INSTRUCTI❑NS SUPPLIED BY MFGR AND HAVE <br />MANUFACTURERS SPECIFICATI❑NS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTI❑N FOR REVIEW BY THE <br />BUILDING INSPECT❑R. <br />m <br />ALL HURRICANE CLIPS, STRAPS AND FASTENERS ARE TO BE APPLIED ACC❑RDING TO THE FASTENERS <br />SCHEDULE AND MANUFACTURERS SPECIFICATI❑NS, IF DESIRED, EQUALVENT CONNECTORS MADE BY ANOTHER <br />SUPPLIER MAY BE USED IN PLACE OF THE CONNECTORS SHOWN, <br />THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTI❑N OF VARI❑US <br />CONNECTED COMPONENTS, PR❑VIDE ADEQUATE BRACING, SH❑RING AND ANY OTHER TEMPORARY SUPPORTS <br />AS REQUIRED TO SAFELY COMPLETE THE WORK. <br />ALL DOORS INTERI❑R & EXTERI❑R ARE 6'-8" UNLESS ❑THERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE TEMPERED GLASS <br />ALL WIND❑WS WITHIN 24" OF DOORS (INTERI❑R & EXTERI❑R) AND WITHIN 18" OF FLR TO BE TEMPERED GLASS. (FBC) R308,4) <br />HURRICAN CLIPS ARE REQUIRED ON ALL TRUSSES AND RAFTERS, IF PLYWOOD OR ❑SB SHEATHING DOES NOT OVER TOP PLATE, <br />HURRICANE CLIPS MUST BE COVER BOTH TOP PLATES. <br />UPLIFT PR❑TECTI❑N: PLYWOOD OR ❑SB C❑VERING ENTIRE EXTERI❑R OF HOME WITH NAILS SPACED 3" D.C. AT TOP AND BOTTOM, <br />6" D.C. ON EDGES AND THE REMAINDER AT 12" Of. OR PLAYW❑❑D OR ❑SB AT CORNERS, WITH HURRICANE STRAPING ON EVERY <br />EXTERI❑R STUD, CRIPPLE, JACKSTUD ETC. AT TOP AND BOTTOM, <br />R302,6 DWELLING -GARAGE FIRE SEPARATI❑N <br />THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302,6, ❑PENINGS IN GARAGE WALLS SHALL COMPLY WITH SECTI❑N R302,5, <br />ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R702,3,5, THE WALL SEPARATI❑N PR❑VISI❑NS OF TABLE R302.6 SHALL NOT <br />APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL, <br />NOT LESS THAN 1/2—INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE, <br />NOTE: <br />R314,3,1 ALTERATI❑NS, REPAIRS AND ADDITI❑NS. WHEN ALTERATI❑NS, REPAIRS ❑R ADDITI❑NS <br />REQUIRING A PERMIT OCCUR) OR WHEN ONE OR MORE SLEEPING ROOMS ARE ADDED OR CREATED IN <br />EXISTING DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED <br />AS REQUIRED FOR NEW DWELLINGS, <br />CONTRACTOR TO INSPECT AND INSURE THAT EXISTING HOUSE HAS SMOKE & CO DETECTORS AT EACH BEDROOM AND <br />AND ❑UTSIDE BEDROOMS WITHIN 10 FEET OF SLEEPING AREAS TO BE IN C❑MPLIANCE <br />EXISTING <br />STORAGE <br />EXISTING <br />,,GARAGE <br />I <br />e�! <br />EXISTING' <br />E <br />OFFICE / / / / <br />XISTING <br />..: <br />5'-10 <br />COVER PORCH <br />IR-LE'AIR, _V`_7.1LE VA TIO 1\1 <br />I hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W. Smith, P.E. #53608 <br />I <br />9'-5 <br />EXISTING <br />EGRESS <br />SH24 <br />SH24 <br />0j <br />LO <br />a <br />NAT/Kor)(00101 <br />AREA'S <br />LIVING 284 <br />COVERED PORCH 168 <br />TOTAL AREA UNDER R❑❑E 452 S,E, <br />All WORKSHALL C; 1r;t� <br />CODES FLORIDA N VV1 H PREVAILING <br />NA''1ONAL ELEC? O LOI fO CODE, <br />AN �lr ClTY RIC CODE <br />OR <br />0-INANCES OF E YI�HILLS <br />SH24 SH24 <br />IG HT E V A TI 0 N <br />PARCEL: 03-26-21-0130-00000-0430 <br />D.W.SMITH,M.S.,P.E.#53608 PRATT GREGORY <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 6106 R I D G EWAY DR <br />PROJECTS ENG1rNEERING CONSULTANT ZEPHYRHILLS, FLORID <br />PHO�E (CEL ) 813-4 9-2 WALLASTON 89 I VE—DAD E- AIL1 dwsf 1pE CITY ❑0eaDrtth l3 k n t ELEVATIONS <br />RICK GOLLHARDT — DRAFTSMAN <br />PHONE1( CELL) 813-781-3651 E-MAIL1 roollhardt@tare <br />FLOOR PLAN <br />SCALE DATE <br />DO NOT SCALE 7 NOV 2021 <br />DESIGN/DRAWN CHECKED <br />rr,com R. GOLLHARDT D.W.S.PE <br />SHET OF <br />1 Ot 4 <br />JOB JNO, <br />2021-0520 <br />_. _ - _ _ i _ �, l.. � �u � i6 il-�,�J,➢ sl. 11«I' ;I (Ilk r��r m'Y tikal 11 IN :.. I:! ,��;.� ,1! i, ral: <br />