Laserfiche WebLink
PRODUCT <br />CATEGORY <br />MANUFACTURER <br />SERIES OR <br />MODEL # <br />APPROVAL # <br />FLA OR MIAMI <br />APPROVAL VERSION <br />EXTERIOR DOORS <br />SWINGING <br />JELD-WEN <br />PREMIUM ATLANTIC IMPACT <br />10495.1 <br />FL 10495-R11 <br />PREMIUM ATLANTIC NON -IMPACT <br />10495.2 <br />JELD-WEN <br />DESIGN PRO/SMOOTH PRO <br />16674.2 <br />FL 16674-R16 <br />IMPACT X AND XX 80 AND 96 <br />16674.4 <br />THERMA-TRU <br />BENCHMARK X IMPACT <br />17540.1 <br />FL 17540-R5 <br />BENCHMARK OX XO OXXO IMPACT <br />17540.2 <br />BENCHMARK X IMPACT 8 <br />17540.3 <br />BENCHMARK XX XO OXXO 8' IMPACT <br />17540.4 <br />THERMA-TRU <br />SMOOTH-S iAR X IMPACT <br />20468.1 <br />FL 20468-R5 <br />SMOOTH -STAR OX XO OXXO IMPACT <br />20468.2 <br />SMOOTH -STAR X IMPACT 8' <br />20468.3 <br />SMOOTH -STAR XX XO OXXO 8' IMPACT <br />20468.4 <br />MASONITE <br />FIBERGLASS NON -IMPACT <br />22363.3,11 <br />FL 22363-R6 <br />FIBERGLASS IMPACT <br />22363.6,9 <br />PGT <br />FD-ALUM NON -IMPACT <br />253.3 <br />FL 253-R22 <br />FD-ALUM IMPACT <br />253.4 <br />SLIDING <br />PGT <br />SERIES 5570 NON -IMPACT <br />251.8 <br />FL 251-R33 <br />SERIES 5570 IMPACT <br />251.9 <br />JELD-WEN <br />PREMIUM ATLANTIC VINYL NON <br />11109.2 <br />FL 11109-R9 <br />JELD-WEN <br />PREMIUM VINYL IMPACT <br />21705.3 <br />FL 21705-R5 <br />JELD-WEN <br />PREMIUM VINYL 72X80 NON <br />12425.1 <br />FL 12425-R12 <br />PREMIUM VINYL 96X96 NON <br />12425.2 <br />SECTIONAL/ROLL UP <br />CLOPAY <br />73, 75 (9'2"-16'2") IMPACT <br />16107.3 <br />FL 16107-R13 <br />73, 75 (9'2"-16'2") NON <br />16107.4 <br />73, 75 (16'4"-18'2") IMPACT <br />16107.11 <br />73, 75 (16'4"-18'2") NON <br />16107.12 <br />73, 75 (UP TO 9'2") IMPACT <br />16107.24 <br />WINDOWS <br />73, 75 (UP TO 9'2") NON <br />16107.25 <br />SINGLE/DOUBLE HUNG <br />JELD-WEN <br />PREMIUM ATLANTIC VINYL IMPACT <br />14095.1 <br />FL 14095-R11 <br />PREMIUM ATLANTIC VINYL NON <br />14095.2 <br />PGT <br />SERIES 5500 NON <br />239.1 <br />FL 239-R28 <br />SERIES 5500 IMPACT <br />239.2 <br />MI WINDOWS & DOOR <br />SERIES 185 IMPACT <br />17499.1 <br />FL 17499-R8 <br />SERIES 185 NON <br />17499.3 <br />SILVERLINE <br />SERIES 70 NON -IMPACT <br />14911.4 <br />FL 14911-R12 <br />SERIES 70 IMPACT <br />14911.5 <br />HORIZONTAL SLIDER <br />PGT <br />HR-ALUM IMPACT <br />242.2 <br />FL 242-R28 <br />MI WINDOWS & DOOR <br />SERIES 188 NON <br />15351.1 <br />FL 15351-R8 <br />SERIES 188 IMPACT <br />15351.3 <br />JELD-WEN <br />PREMIUM VINYL IMPACT <br />22368.1 <br />FL 22368-R5 <br />FIXED <br />PGT <br />PW-ALUM NON <br />243.5 <br />FL 243-R24 <br />MI WINDOWS & DOOR <br />SERIES 185 NON <br />15349.4 <br />FL 15349-R14 <br />SERIES 185 IMPACT <br />15349.5 <br />MILLION <br />PGT <br />SERIES 5500 <br />261.1 <br />FL 261-R13 <br />MI WINDOWS & DOOR <br />SERIES 5764 <br />15353.2 <br />FL 15353-R5 <br />JELD-WEN <br />MILLIONS <br />15861.1 <br />FL 15861-R9 <br />PANEL WALL <br />SIDING <br />KAYCAN <br />SIDING <br />16299.2 <br />FL 16299-R5 <br />JAMES HARDIE <br />13192.2 <br />FL 13192-R6 <br />SOFFITS <br />KAYCAN <br />SOFFIT <br />16503.3 <br />FL 16503-R5 <br />ALSIDE <br />SOLID AND VENTED SOFFIT <br />15272.1 <br />FL 15272-R3 <br />JAMES HARDIE <br />SOFFIT <br />13265.1 <br />FL 13265-R5 <br />ROOFING <br />ASPHALT SHINGLES <br />GAF <br />SHINGLES <br />10124.1 <br />FL 10124-R29 <br />IKO <br />SHINGLES <br />30310 <br />FL 30310-R1 <br />TAMKO <br />SHINGLES <br />18355.1 <br />FL 18355-R6 <br />TPO <br />GAF <br />SINGLE PLY ROOF SYSTEMS <br />16730.1 <br />FL 16730-R30 <br />METAL ROOFING <br />UNION CORRUGATING <br />MASTERRIB PANEL <br />9555.4 <br />FL 9555-R4 <br />ALUMFLO <br />.024 3' RISER PAN ROOF <br />22840.1 <br />FL 22840-R2 <br />.030 3' RISER PAN ROOF <br />22840.2 <br />24GA 3' RISER PAN ROOF <br />22840.3 <br />26GA 3' RISER PAN ROOF <br />22840.4 <br />UNDERLAYMENT <br />TAMKO <br />UNDERLAYMENT HVHZ <br />12328.1 <br />FL 12328-R9 <br />UNDERLAYMENT NON-HVHZ <br />12328.2 <br />GAF <br />UNDERLAYMENT <br />10626.1 <br />FL 10626-R19 <br />ROOF VENTILATORS <br />THOMPSON ARCH METAL <br />OFF RIDGE VENT <br />16918.3 <br />FL 16918-R3 <br />FLORIDA METAL PROD. <br />OFF VENT RV10 <br />21580.1 <br />FL 21580-R2 <br />RIDGE VENT <br />21580.3 <br />LOMANCO <br />RIDGE VENT <br />17202.1 <br />FL 17202-R6 <br />STORM PANELS <br />GLOBAL PROTECTION PROD <br />GALV STORM PANELS HVHZ <br />15076.1 <br />FL 15076-R6 <br />GALV STORM PANELS NON-HVHZ <br />15076.2 <br />STRUCTURAL COMPONENTS <br />CAST-CRETE USA <br />CONCRETE LINTELS <br />158.1 <br />FL 158-R13 <br />COMMERCIAL CONCRETE PRODUCTS <br />CONCRETE LINTELS <br />1774.1 <br />FL 1774-R6 <br />MARION MASONRY MATERIALS <br />CONCRETE LINTELS <br />12193.1 <br />FL 12193-R5 <br />CONCRETE PRECAST PRODUCTS <br />CONCRETE LINTELS <br />15148.1 <br />FL 15148-R3 <br />LOTT'S CONCRETE PRODUCTS <br />CONCRETE LINTELS <br />17867.1 <br />FL 17867-R2 <br />SYMBOL <br />DESCRIPTION <br />$ <br />SWITCH <br />$3 <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />110 V RECEPTICLE(1/2 SWITCHED) <br />110 V RECEPTICLE <br />8GFI <br />110 V RECEPTICLE - GROUND FAULT <br />8AFI <br />110 V RECEPTICLE - ARC FAULT <br />8wP <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />6 <br />220 V RECEPTICLE <br />[�] <br />DUPLEX OUTLET IN FLOOR <br />110 V QUAD <br />awP <br />110 V QUAD WATERPROOF OUTLET <br />® <br />RECESSED INCANDESCENT <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />FL❑URESCENT FIXTURE <br />FLOOD LAMPS <br />o <br />VANTITY LIGHT <br />GD <br />PUSH BUTTON FOR GARAGE OPENER <br />SBn <br />SMOKE /FIRE DETECTOR/ALARM <br />C&M <br />SMOKE/CARBON MON❑XIDE DETECTOR - COMBO <br />CARBON M❑N❑XIDE DETECTOR <br />E::P <br />DISC❑NNECT <br />n <br />I/ <br />-� <br />CEILING FAN ONLY <br />L/ �J <br />n <br />I/ <br />CEILING FAN /LIGHT <br />FAN W/L <br />=p <br />DISC❑NNECT SWITCH <br />ELECTRICAL METER <br />1] <br />ELECTRICAL PANEL <br />EXISTING <br />GARAGE <br />SMOKE DETECTORS: <br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE <br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN <br />7TH EDITION, 2020 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017). <br />CARBON MONOXIDE DETECTORS: <br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01 /08 AND HAVING A <br />FOSSIL-FUEL-BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL <br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION, <br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL <br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP. <br />ELECTRICAL: <br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER <br />2020 7TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART Vill - ELECTRICAL) <br />NEC 2017: 210.12 - ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS. <br />NEC 2017: 210.8 - INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS, <br />PORCH AND LANAI. <br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN. <br />OFFICE <br />AFI <br />ll'601V <br />EXISTING <br />I�AFI =0 <br />AFI <br />I + <br />I + <br />1 \� WP <br />AFI <br />/ \ 0 CL I <br />/FAN W%L Z I <br />.BEDROOM <br />AFI <br />DD <br />I <br />�¢ AFI AFI <br />� I4' <br />COVER PORCH <br />EL_Ll_�,CTRICAL <br />HVAC <br />MECHANICAL: <br />CONDENSATE LINES SHALL DISCHARGE AT LEAST 12" AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND <br />PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. <br />20 FMC, TH EDITION - EQUIPMENT DISCONNECT MUST BE WITHIN SIGHT OF THE EQUIPMENT. <br />BATHROOMS MUST BE VENTILATED MECHANICALLY AND EXHAUSTED TO BUILDING EXTERIOR. <br />AIR HANDLER FLOAT SWITCHES ARE REQUIRED TO SHUT DOWN THE UNIT OR OTHER APPROVED <br />OWNER THAT THE CONDENSATE DRAIN LINE IS NOT WORKING PROPERLY. <br />NOTES: <br />UNLESS ❑THERWISE NOTED <br />1. <br />ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERI❑R WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2, <br />ALL TRIM PLATES & DEVICES <br />TO BE GANGED, WHERE <br />P❑SSIBLE <br />3. <br />ELECTRICAL SWITCHES TO BE 42" CENTERLINE AFF, <br />4. <br />ELECTRICAL PLAN IS INTENDED FOR <br />BID PURPOSES ONLY. ALL <br />WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATI❑NAL ELECTRIC CODE, LATEST <br />EDITI❑N, BY LICENSED ELECTRICAL <br />CONTRACTOR WHO SHALL BE <br />RESP❑NSIBLE <br />FOR THE INSTALLATI❑N & SIZING OF <br />ALL ELECTRICAL, WIRING & <br />ACCESS❑RIES. <br />5. <br />GROUND WIRE FORM REBAR TO <br />ELECTRICAL PANEL PER <br />N.E.C, 2017 <br />DEVICE TO ALERT THE HOME <br />THERE MUST BE A NOTICE POSTED ON THE ELECTRICAL PANEL ALERTING THE HOME OWNER THAT THE AIR HANDLER IS <br />LOCATED IN THE ATTIC (WHEN APPLICABLE). <br />NOTE: <br />MECHANICAL CONTRACTOR TO DETERMINE UNIT SIZE PER ENERGY CALCULATIONS <br />IN ACCORDANCE WITH CHAPTER 471,003 (2) OF THE FLORIDA ADMINSTRATI❑N CODE, <br />MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES, THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS. <br />D.W. SMITH, M.S.,P.E.#536®8 <br />FLORIDA PROFESSI❑NAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE-DADE CITY, FLORIDA 33525 <br />PHONE: ( CELL) 813-469-2289 E-MAIL: dwsf l pe@earth l i nk. net <br />PRATT GREGORY <br />6106 RIDGEWAY DR <br />ZEPHYRHILLS, FLORIDA <br />ELECTRICAL/HVAC <br />SHEET OF <br />t <br />SCALE <br />DO NOT SCALE <br />RICK GOLLHARDT - DRAFTSMAN DESIGN/DRAWN <br />PHONE: (CELL)813-781-3651 E-MAIL: rw I lhardt@tamDabav, rr, corl R . GO LLHAR DT <br />7 NOV 2021 <br />CHECKED <br />D.W.S.PE <br />4OF4 <br />2021-0520 <br />