My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6238 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6238 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:52:55 PM
Creation date
2/19/2025 12:50:12 PM
Metadata
Fields
Template:
Building Plans
Street #
6238
Location
Back Forty Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
6281
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />A/C <br />DISCONNECT <br />WP <br />GFI <br />El <br />GFI GFI <br />o <br />'- <br />GFI AT <br />r i 30" A.F.F. r TV <br />7TO <br />GF . HDMI <br />_ \ <br />6-11 <br />AV—�4J d-0 <br />II � r <br />LIVING <br />ROOM <br />FI GF AT <br />30" A.F.F. !! !! <br />GFI KITCHEN <br />Air 6-0" <br />0 <br />u_ A \ <br />F Q LU <br />JGF <br />o <br />� w Q > F < DINING <br />U ROOM W GF <br />¢O <br />m GFI PW_DR\ <br />WH \ rBATH <br />0 <br />ELEC \ 2'-11" <br />PANEL <br />',T) <br />! TWO CAR GARAGE <br />48 GFI o <br />M <br />GFI I CS TO 2ND <br />GFI i ! FLR ELEC' <br />110V CLG- i <br />I <br />MNT. i <br />--- OUTLET ---!--- <br />I ! I o <br />3 <br />O I /. <br />- <br />0 <br />0 <br />GFI ENTRY <br />i <br />L------------------L <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B <br />1 /4„ = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 <br />200 AMP 10 <br />#12 copper to 20 amp ckts <br />01 <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />' 150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NITS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />T <br />SWITCH <br />° <br />4 1/2" <br />DOORJAMB <br />DUPLEX <br />OUTLET c� <br />TRIM <br />o <br />0 <br />BASE <br />TE: <br />F <br />L DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />kSr� <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-�- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />--o DIMMER SWITCH AT 36" <br />-{7 PUSH-BUTTON DOORBELL <br />-�A3- CLG MNT LT FIXTURE <br />=} CLG MNT PREWIRE - FIXTURE BY OWNER <br />-�- SURFACE MNT FIXTURE <br />{- WALL MNT FIXTURE <br />NOTE: <br />C 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4) " USED IF 50W PAR30 NFL 6WHITE BAFFLE <br />C APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />v CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CosCOMBINATION <br />DETECTOR <br />0j SMOKE DETECTOR <br />CU-18- UNDER CABINET 18" <br />cS-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 - SINGLE 36" FLUOR STRIP <br />D-36 - DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:P 24" VANITY LIGHTING <br />9;;-, 36 -;FR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />-il—Ii, ELEC PANEL <br />VACUM OUTLET AT 12" <br />WAI CEILING RETURN AIR <br />EEI A/C REGISTER <br />(TJ THERMOSTAT <br />011 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br />A' M LO N E <br />W L C <br />U <br />0cmc�' <br />cn <br />VN`0'� <br />O M u <br />w a <br />C' L M <br />�Oo 20 <br />*" <br />LL OO D <br />T �1 • Q <br />nN <br />V w aN <br />E"o <br />W <br />L <br />CL <br />(9/) <br />W <br />LLJU W <br />0 LLj to W OLU <br />f-Q X J of z0� <br />W°2-J<0�:ww <br />Q F-- <br />V <br />002�o <br />C�O<wO-ORO0M-0,z <br />�WQ W—WWW(5wQf<0 <br />Z <br />¢~WpW< wzOo�OpQ <br />LL <br />00 0 D Q Q W¢ <br />u- ¢ O i- tL <br />O <br />O <br />Z CNI <br />O F- <br />U ::) ti <br />� <br />' 0 M O <br />a <br />w< <br />ti <br />z <br />LL, < Lq <br />F- fY cM <br />Z00 <br />C) <br />w <br />W <br />C:) <br />O <br />� <br />Vi <br />tua@ <br />Revi <br />w, A <br />@ens Re <br />iew <br />corn <br />Ike <br />sjst <br />$23 <br />compiia <br />Et <br />a <br />bra <br />tht <br />e2 <br />anNr <br />2®Fby <br />ion <br />nn <br />I <br />Kla <br />I <br />r p <br />I <br />0 <br />NO <br />o <br />O <br />0 <br />N <br />O— <br />C <br />N <br />0 <br />N <br />0 <br />CO <br />0 <br />�V <br />r- <br />Co- <br />00 <br />O <br />O <br />e— <br />O <br />N <br />C1 <br />O <br />N <br />\ <br />N <br />O <br />z <br />O <br />r <br />r <br />O <br />O <br />(D <br />i <br />' <br />O <br />NLOW <br />o <br />0 <br />0 <br />0 <br />0 <br />0 <br />l <br />LO <br />�y <br />> <br />1- 1 <br />N <br />co <br />cl <br />U) <br />co <br />i <br />' <br />Cr <br />o <br />v, <br />z <br />� <br />Q <br />0 <br />W <br />Z� <br />O <br />WOO <br />� Uzj <br />O0 <br />0 <br />Z <br />—0- <br />LU <br />(D <br />LU <br />� w <br />it <br />z 0 = <br />W <br />g~ <br />O <br />zoo <br />Z <br />U <br />a-Z� <br />LL <br />r <br />S2z <br />Q <br />J <br />OC� <br />0 <br />0.. <br />z <br />z <br />z <br />w <br />w <br />J <br />O <br />0 <br />0 <br />N <br />LAST PLOT DATE <br />z <br />0 <br />J <br />1 ST FLOOR <br />ELECTRICAL PLAN B <br />---I- T--T--FT1-.- f- i - _- - - - - __- - - — _ r1I0'II IIP;�L��i `I -lr ���ueli :�LI IGd �i eL�.ill�I: iriPi�i la l,: uln "�f:' III'0,,1, 1 ]1 11 11 1- 11 1If <br />
The URL can be used to link to this page
Your browser does not support the video tag.