Laserfiche WebLink
0 <br />3 <br />ALL STAIR STRINGERS <br />AND TREADS TO BE <br />#2 SYP (MIN.) <br />THREADS, RISERS, AND <br />3/4" PLYWOOD NOT <br />SHOWN IN DETAIL FOR <br />CLARITY <br />ALL WOOD TO WOOD <br />CONNECTIONS TO BE <br />GLUED (PL 200) AND <br />NAILED (MIN. (2)16d). <br />13/4x11 <br />VL <br />2x4 UNDER STRINGER - <br />GLUED AND NAILED TO <br />LANDING <br />2x4 UNDER STRINGER GLUED A <br />NAILED TO LANDING BLOCKING <br />D <br />2x4 PT NOTC <br />INTO STRINGER <br />H D <br />2x8 BLOCKING FOR STRAP <br />L-1x4 blocking <br />SIMPSON MSTA21 w/ (16) 10d NAILS E <br />FLAT STRAP NAILED TO RISER AND <br />THEN WRAPPED AROUND STUD - <br />PLAN VIEW <br />SCALE: " =1'-0" <br />2x4 SPF NOSING GLUED AND <br />NAILED MATCH NOSING ON <br />OTHER TREADS' <br />JOIST <br />STRINGER MUST MAKE FU <br />CONTACT WITH LANDING <br />SIMPSON A35 OR <br />LSC EACH <br />STRINGER <br />2x4 CUT ON BEVEL <br />DOES NOT BEAR IN <br />D D WALL GLUED TO <br />F 2x8 <br />SYP <br />2x8 SYP <br />2x8 <br />SYP <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />=2x12 SYP <br />BEARS IN WALL <br />`-2x6 SYP <br />B-� <br />2x12 SYP <br />SCAB 2x4 GLUED AND NAILED (EACH <br />ALIGN THIS STUD WITH <br />STRINGER <br />SIDE) TO BOTTOM EDGE OF 2x12 <br />FACE OF 2ND RISER 3/4" RISER CUT TO FIT <br />STRINGER <br />MAINTAIN BETWEEN" <br />AND J" GAP TOP AND <br />BOTTOM, GLUED AND <br />NAILED TO STRINGER <br />% <br />2x4 BEHIND RISER <br />BLOCKING FOR <br />1x4 GLUED AND NAILED TO STRINGER <br />STRAP GLUED TO <br />2x4 DRAFT <br />RISER AND TREAD <br />STOP <br />2x8 SYP DRYWALL STOP MUST <br />TOUCH STRINGERS <br />zANOT <br />`- 2x4 SYP BLOCKING <br />/2x4 PT NOTCHED INTO STRINGER FOR STRAP <br />AND NAILED TO FLOOR WITH GLUE (SIMPSON MTS12 w/ <br />/ AT STRINGER CONTACT POINTS \ NAI S) x 1 1/2" <br />NAILS) / <br />SECTION VIEW "A" <br />STRINGER MUST MAKE <br />FULL CONTACT WITH LANDING <br />SIMPSON A35 OR <br />LSC EACH <br />STRINGER <br />2x4 CUT ON BEVEL - <br />DOES NOT BEAR IN <br />WALL <br />SECTION VIEW "B" <br />SCALE: 1" = T-0" SCALE: 1" = 1'-0" <br />ALIGN THIS STUD WITH FACE OF 2nd RISER <br />�4 <br />-2x4 BLOCKING FOR 2x12 <br />•2x4 PT UNDER 2x12 C <br />ROVIDE MOISTURE <br />PROTECTION <br />ATTACH ALL COMPONENTS <br />OF STAIR TO CONC. W/ J" X <br />2 t" TAPCONS @ MAX. 32" O.C. / <br />ATTACH ALL COMPONENTS \ 1x4 GLUED AND <br />OF STAIR TO CONC. W/T" X NAILED TO STRINGER <br />2" TAPCONS @ MAX. 32" O.C. / <br />/ 1x4 GLUED AND NAILED TO STRINGER <br />2x4 DRAFT <br />STOP <br />2x8 SYP DRYWALL STOP <br />MUST NOT TOUCH <br />STRINGERS <br />R <br />2x4 BLOCKING FOR 2x12 SIMPSON A35 <br />2x4 PT UNDER 2x12 OR LSC EACH <br />G-1 SECTION VIEW "C" <br />\ SCALE: 1" = 1'-0" <br />TOP OF <br />STRINGER <br />2x4 SYP BLOCKING <br />FOR STRAP <br />(SIMPSON MTS12 w/ <br />2x4 PT NOTCHED INTO STRINGER <br />x 1 1/2" <br />AND NAILED TO FLOOR WITH GLU <br />N <br />NAILS) <br />AILSS)) <br />AT STRINGER CONTACT POINTS \ <br />SECTION VIEW "D" <br />SCALE: 1" = 1'-0" <br />FILLER STRIPS ADDED "PLYWOOD <br />GLUED & SCREWED TO <br />PLYWOOD DECKING <br />2x SYP CUT TO FIT <br />BEARS IN WALL <br />—2x12 SYP <br />BEARS IN WALL <br />BULLNOSE DETAIL <br />SCALE: 1" = T-0" <br />2x4 GLUED <br />AND NAILED <br />SECTION D—D <br />3/4 PLYWOOD <br />ON DECK <br />3/4" RISER CUT TO FIT <br />2x•4 SYP BLOCKING <br />MAINTAIN BETWEEN 1/4" <br />FOR STRAP (SIMPSON <br />oo <br />AND 1/2" GAP TOP AND <br />MTS12 w/ (14) 10d x 1 <br />SYP GLUED <br />BOTTOM, GLUED AND <br />1/2" NAILS) <br />AND NAILED TO <br />NAILED TO STRINGER <br />FRAMING <br />x4 DRAFT 2x12 <br />STOP TREAD <br />2x12 TREAD <br />GLUED <br />GLUED AND <br />AND <br />NAILED —v <br />NAILEE <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE — <br />AT STRINGER CONTACT <br />POINTS <br />2x8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />2x4 BLOCK IN KNEEWALL FOR 2x12 NAILING <br />x4 GLUED AND NAILED TO STRINGER <br />FOR DRYWALL SPACING <br />H SECTION VIEW <br />SCALE: " = 1'-0" <br />2x4 PT NOTCHED INTO <br />STRINGER AND TAPCONED <br />INTO FLOOR WITH GLUE — <br />AT STRINGER CONTACT <br />POINTS <br />V <br />SCALE: 1" = V-0" <br />SECTION VIEW "E" <br />SCALE: 1" = 1'4" <br />8 SYP DRYWALL STOP MUST <br />NOT TOUCH STRINGERS <br />LX4/GLUED AND NAILED TO STRINGER <br />—� FOR DRYWALL SPACING <br />H <br />E SECTION VIEW <br />SCALE: " = 1'-0" <br />3/4 PLYWC <br />ON DECK <br />--2x8 SYP <br />AND NAI <br />FRAMIN( <br />2x4 DRAFT <br />STOP <br />2x4 BLOCKI <br />C—, <br />NOTE: 2x8 <br />DRYWALL STOP <br />NOTSHOWN <br />OPTION: 2X4 CUT ON <br />BEVEL GLUED AND <br />NAILED TO SUPPORT <br />W/ SIMPSON H3 — <br />FLOOR TRUSS OR <br />GIRDER, FIELD VERIFY <br />(2) LAYER" EDGE GOLD <br />OSB OR PLYWOOD <br />OR 1 t"X16" LVL <br />ATTACHED W/ 12d NAILS <br />@ 6" O.C. TOP, BOTTOM <br />AND VERT. <br />SECTION VIEW "G" <br />SCALE: 1" = 1'-0" <br />F SECTION VIEW <br />SCALE:" = 1'-0" <br />CONN. TO BOTT <br />OF NEWEL POST <br />PER CONTRACT <br />a <br />PROVIDE SOLID BLOCKING <br />BELOW ALL NEWEL POST <br />FROM JOIST TO JOIST. USE <br />2 X 12 BLOCKS, GLUED AND <br />NAILED TO JOIST. <br />L POST LET INTO <br />LOCK <br />IDE <br />KING <br />2X8 BLOCKING <br />FOR NEWEL POST <br />TO ANCHOR TO. <br />(GLUED AND NAILED) <br />FLOOR <br />TRUSSES <br />NEWEL POST <br />BLOCKING <br />STAIR CONSTRUCTION DETAILS <br />(IF 11X17 REDUCE SCALE .5) SCALE: AS NOTED <br />SCALE: 1" = 1'-0" <br />JOINT <br />-TO <br />)ISTS) <br />NAILED AND <br />)TOP PLATE <br />NTO RIM BAND, <br />ID NAILED TO <br />WALL BELOW <br />JOINT <br />-TO <br />)ISTS) <br />2X B OCKING <br />1 MTS 2 w/ <br />10d x 1 1/2" NAILS — <br />VARIES <br />ECTION VIEW "H" <br />SCALE: 1" = 1'-0" <br />V C W <br />Boa., o <br />9- <br />N <br />N cc C <br />.a N <br />- <br />x " •3s <br />ix. <br />c � <br />� o <br />0 <br />�. Y Y d"f <br />v �QO <br />tr <br />> {J <br />�J N <br />A <br />fr:s�I R0FESSIO <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the stnnturai engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />a o �8 <br />C14 0 <br />C 0.9 �� <br />t» NNo- M -U,N fh 'Q S J , <br />Q C J iz U_ W <br />J ILLL 0. <br />Z d °' ( <br />Wr 2 CP w <br />U) co Z d J <br />ZN OU v <br />W pp <br />z � '- <br />z <br />z� <br />Q <br />N <br />U) Z <br />f0 W <br />� <br />V � <br />O „, s <br />N c <br />Uj <br />'® 2 <br />_ <br />U <br />c <br />• <br />E <br />C <br />g <br />d <br />o0 <br />?9 <br />oa <br />fdU <br />0OV <br />Z <br />E <br />L <br />ry <br />co <br />C <br />¢p <br />.0 <br />s <br />yo <br />ZLL <br />Q W <br />Z <br />J� <br />o� <br />iZ <br />0 <br />W <br />U7 <br />� <br />U � <br />w� <br />�o <br />�zW <br />Nw <br />NLL <br />J <br />2� <br />M <br />O <br />, <br />O <br />^` <br />i <br />TT <br />Co <br />C—) <br />T <br />r <br />Cr <br />N <br />m <br />LO <br />~ <br />O <br />O <br />(V <br />O <br />N <br />C <br />Q N <br />r <br />ui <br />N <br />Z` N <br />E O <br />c <br />z <br />z <br />c <br />In <br />E <br />E 8i <br />a <br />U Q p <br />JOB <br />NO: 22-06451 <br />SCALE: AS NOTED <br />SHEET NO. <br />ST <br />