My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6288 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6288 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:37:49 PM
Creation date
2/19/2025 12:50:54 PM
Metadata
Fields
Template:
Building Plans
Street #
6288
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5474
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_M <br />3/4" PLYWOOD <br />DECKING <br />2x6 LANDING- <br />2x4 FRAMING . <br />ih <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSI <br />42" KNEE WALL WITH <br />1x8 CAP & CASING OR <br />36" RAILING <br />3/4" PLYWOOD <br />DECKING <br />PRE-ENG FLOOR <br />TRUSS <br />1x TREAD (TYP.) <br />�' <br />1 <br />1x RISERS (TYP.) <br />\I r <br />(3) 2xl2 <br />42" KNEE WALL WITH f` <br />STRINGERS <br />tx8 CAP & CASING OR <br />3 <br />36" RAILING <br />3/4" PLYWOOD <br />2 1 <br />7 <br />THRUST,' BLOCK <br />DECKING <br />2x6 LANDING - <br />2x4 FRAMING <br />36" H. CONT. <br />GRASPABLE <br />RAILING <br />TYP. STAIR SECTION. <br />2x4 THRUST <br />BLOCK <br />rway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 and R302.7. <br />ar height: <br />riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading edges of the <br />(cent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />ad depth: <br />tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the vertical planes of <br />foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any <br />It of stairs shall not exceed the smallest by more than 3/8 inch. <br />✓Under treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the foremost <br />xojection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread depth of not less than 6 <br />riches at any point within the clear width of the stair <br />the radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 inch and not <br />pore than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing projection shall not exceed the <br />smallest nosing projection by more than 3/8 inch between two stories, including the nosing at the level of floors and landings. <br />3eveling of nosings shall not exceed 1/2 inch. <br />iandrails: <br />iandrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. Handrail <br />might measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less <br />:han 34 inches and not more than 38 inches. Handrails for stairways shall be continuous for the full length of the flight, from a <br />Joint directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be <br />eturned or shall terminate in newel posts or safety terminals. Handrails adjacent to a wall shall have a space of not less than <br />11/2 inches between the wall and the handrails. <br />3rip-size: <br />-landrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater than 2 inches <br />)r provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />3uards: <br />3uards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 <br />riches measured vertically to the floor or grade below at any point within 24 inches horizontally to the edge of the open side. <br />Required guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 <br />riches in height as measured vertically above the adjacent walking surface or the line connecting the leading edges of the <br />:reads. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a <br />sphere 4 inches in diameter. <br />Jnder-stair protection: <br />nclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the enclosed side <br />Nith 1/2-inch gypsum board. <br />I SEE PLAN FOR LANDING DEPTH I <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1. <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM O <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENC <br />LANDING FOF <br />STRINGERS 7 <br />CONNECT TC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />CONT. HANDRAIL <br />RETURN TO <br />(:0)WALL DETAIL <br />SCALE: NTS <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L-------------------------------------J <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />EXTERIOR WALLS <br />REVISION NOTES 12/17/2009: <br />1. ALL CLOSETS THAT ARE NOT WALK-IN CLOSETS <br />ARE TO BE FRAMED DOWN TO 8'-0" A.F.F. <br />2. ALL BLOCK WALL FURRING IS TO BE 24" O.C. <br />EXCEPT IN WET AREAS. SPACE WET AREA <br />FURRING AT 16" O.C. <br />3. NO RECESSES FOR SHOWERS. SHOWERS ARE <br />TO BE PANNED WITH A PRE-FAB. BASE. <br />4. ALL VANITY HEIGHTS ARE 36" A.F.F. <br />5. SLIDING GLASS DOORS ARE TO HAVE A 1-1/2" <br />RECESS. REFER TO MASON'S SCOPE FOR <br />RECESS WIDTH. <br />6. ALL BATHROOMS HAVE ONE MEDICINE CABINET <br />7. ALL 50' PLANS. FRAME BAR TOP AT 40-1/2" A.F.F. <br />8. ALL TUB DECKS ARE SIZED AS FOLLOWS; <br />40' PRODUCT LINE - MIN. 48" x 64" <br />50' PRODUCT LINE - MIN. 48" x 76" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2- <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) -1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />(2) - 1 3/4" X 7 1/4' <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />' VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />*' SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />Q�) <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -37.0 <br />DE <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH ftftim <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X251 <br />S.H. <br />13 <br />20 X 381 <br />18 J X 37 i <br />S.H. <br />14 <br />20 X 501 <br />18 J X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 I X 621 <br />S.H. <br />16 <br />20X72 <br />18JX71J <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />iH3 <br />271/4X383 <br />26x371 <br />S.H. <br />1 H4 <br />2714 X 508 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 1 X 63 <br />26 X 62 1/2 <br />S.H. <br />1H6 <br />27 1 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 � X 26 <br />36 � X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 a <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 a <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />3612 X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />36JX71112 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 J <br />S.H. <br />33 <br />54 X 38 J <br />521 X 371 <br />S.H. <br />34 <br />54 X 501 <br />52 � X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 1 X 62 1 <br />S.H. <br />36 <br />54 X 72 <br />52 1 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />WA <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. I <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA <br />SECOND FLOOR LIVING AREA <br />952 S. F. <br />1121 S.F. <br />TOTAL LIVING AREA <br />2073 S. F. <br />GARAGE <br />396 S. F. <br />LANAI <br />104 S. F. <br />ENTRY <br />32 S. F. <br />TOTAL SQ. FT. <br />2605 S. F. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />JR-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN - A <br />SCALE: N'=1'-0" <br />its <br />4 <br />iV <br />c <br />o <br />cc? <br />=o <br />W <br />N <br />c� c <br />V <br />Cn <br />c `°mX <br />=4- <br />Oa <br />Q d dC <br />da <br />�d <br />owe <br />CC V cc <br />3 '- <br />cc <br />c a <br />y ca T <br />� E <br />n <br />c� Q <br />it <br />•� <br />.(o <br />s"'y•cv. J.� j <br />J <br />�� �• <br />•' 1.0 •' <br />a• .••,.F <br />ES <br />fs'rfrftJt t111t�1'�\�� <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />ai <br />h <br />Q <br />E <br />o g $ <br />co <br />Oems. <br />O <br />Co N_ ' <br />3 Lin <br />ai <br />CN M O V LL <br />C J LL W <br />Z-vrn <br />jLLu W o <br />a is <br />rMC 0 <br />W <br />III,z1� <br />ILW <br />r°nO'O' m <br />.�j <br />NIL <br />W <br />❑❑ <br />UI M <br />`� <br />Z � M <br />z � <br />z o <br />v <br />U) <br />a <br />N <br />'- <br />V <br />Lz <br />�O <br />w <br />�tit <br />r <br />c d <br />J3 <br />_w W <br />026 <br />._ <br />Q N°°NJ <br />o <br />co <br />Z <br />o <br />o <br />Z <br />H <br />N V <br />0 <br />11 <br />U <br />I <br />00 <br />0 <br />COU <br />ZN <br />o <br />� <br />a0 <br />wo <br /><o <br />¢� <br />a; <br />NC <br />C <br />Q& <br />mM <br />Z <br />- <br />W O <br />TQZ <br />gZ <br />0 <br />U <br />T <br />a <br />W <br />�LL <br />O <br />a <br />Willa <br />� <br />u <br />°z< <br />°3 <br />.2 C:) <br />= <br />jM <br />J <br />O <br />rn <br />M <br />T <br />� <br />C:) <br />Co <br />T <br />:3 T <br />r <br />00011N <br />Li. <br />in <br />LO <br />O <br />O <br />N <br />CN <br />O <br />Q <br />o <br />N <br />r <br />N <br />r` <br />f0 <br />L <br />7 T <br />N <br />N U') <br />o <br />Z <br />Z <br />C <br />E <br />E <br />B <br />:? <br />C <br />a. <br />U <br />¢ o <br />C <br />0 <br />JOB <br />NO: <br />22-06451 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.