My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6330 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6330 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:52:17 AM
Creation date
2/19/2025 12:51:40 PM
Metadata
Fields
Template:
Building Plans
Street #
6330
Location
Back Forty Lp
Contractor
Lennar Home LLC
Building Plans - Permit #
6034
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x <br />w <br />rn <br />r` <br />i <br />CIO <br />a <br />r7 <br />1.0 <br />0 <br />0 <br />LO <br />LO <br />J <br />N <br />0 <br />M <br />ar <br />v <br />V) <br />0 <br />Q <br />a <br />KJ <br />0 <br />i <br />d <br />E <br />0 <br />0 <br />C <br />J <br />C <br />v <br />LZ <br />0 <br />U <br />E!0 <br />UI <br />U <br />.0 <br />i <br />0 <br />16 <br />U <br />9 <br />LZ <br />M <br />0 <br />0 <br />00 <br />0 <br />CL <br />0 <br />r- <br />r, <br />0 <br />w <br />Q <br />CIO <br />0 <br />1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL <br />DOOR JAMB (REFER t/-, <br />1/2" DRYWALL DOOR JAMB (REFER TO PRODUCT <br />TO PRODUCT <br />TO PRODUCT APPROVAL FOR CONN. 1 X 4 <br />APPROVAL FOR CONN.APPROVAL FOR CONN. <br />1x4 P.T. 1x4 E FURRING <br />3/16 0 X 3 LONG FURRING 2 ROWS 3/16" x 3-1/2" <br />3-1/4" LONG X 3/16" 0 FURRING TAPCONS TAPCON @ 16" O.C. & 4" 2X8 <br />TAPCON. INTO STAGGERED @ 16" <br />BLOCK@ SPACING „ O.C. 2-ROWS INTO 1x8 P.T. FROM EACH END w/ MIN. iX8 <br />PER MANUFACTURE 1 DETAIL 2" EDGE DIST. ATTACH <br />MASONRY THROUGH 1-1 /2" DETAIL 1x8 w/ (2) ROWS 8d NALS �� <br />1x4 P.T. & 1x8 P.T. STAGGERED @ 12" O.C. 3 DETAIL <br />3/16" x 3 -1/2" DOOR JAMB (REFER <br />TAPCON @ 16" 1x4 P.T. TO PRODUCT <br />O.C. & 4" FROM DOOR JAMB (REFER APPROVAL FOR CONN. ix4 1/2" DRYWALL <br />DOOR JAMB (REFER EACH END W/ MIN. TO PRODUCT <br />TO PRODUCT 2" EDGE DIST. APPROVAL FOR CONN. 2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. x 3-1/2" TAPCON @ 16" 1x4 <br />(2) ROWS 3116" x 3-1/2" O.C. & 4" FROM EACH FURRINI <br />TAPCON @ 16" O.C. & END w/ MIN. 2" EDGE DIST. <br />4" FROM EACH END w/ 2x8 P.T. ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D MIN. 2" EDGE DIST. (2) ROWS 10dx3" 2x8 <br />2x DETAIL 2 1/4" DETAIL STAGGERED@12"0' 3-1/4" DETAIL <br />BUILDOUT (c� OVER SIZE DOOR -WINDOW ROUGH OPENINGS/ c \ <br />SCALE: N.T.S. <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45' DIAGONAL (4) 10d NAILS INTO <br />BRACE(S) 2 x 8 BRACE/BLKG. ' <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR-" 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BI <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK - <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW----- <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1/4" MAX <br />it <br />SOLID BLKG. AT TOP BTWN. <br />N ARCH BLKG. & BUCK <br />T-0" <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />�1/4" MAX EMBEDMENT INTO K.) <br />it 2'-0" <br />SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />LEAVE A CUT OUT IN O.S.B. ON TI <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />B_B ARCH DETAIL rK <br />SCALE: N.T.S. SS <br />SECTION <br />A -A <br />8" <br />1/4" x 3 1/4" TAPCONS <br />,LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />---2 x 8 45 DIAAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3) 10d NAILS <br />AT EA. END <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK- (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL 4' MAX. RAD. <br />PROPER INSTALLATION MAX.8 <br />FILL SOLID <br />BOTH CELLS <br />#5 REB <br />(TYP,) <br />STD. 90' <br />HOOK <br />+5A <br />NOTCH WEB AT <br />LL-FIRST 2 COURS <br />...... ;APACITY = 805 # FOR 1 STRAP <br />= 1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />SCREWS & (5) 114" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7) 1/4"x21/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4'Y2" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />(5)12d NAILS SIMPSON <br />2X6 TO 2X4 H2.5A w/ (10) <br />8d NAILS <br />JACK TRUSS PROVIDED BY---/ <br />TRUSS COMPANY OR 2x4 <br />#2 SYP @ 24" O.C. <br />00, <br />4'-0" MAX SEE PLAN <br />2X4 SYP #2 CONT (MATCH TRUSS DEPTH <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP. <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />IF TRUSSES USED) W/ (2) #6 X 4'Y2" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 31/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY rL <br />SCALE: 3/4" = V-0" SS <br />_.) <br />J <br />GLASS BLOCK INSTALLATION NOTES <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />D) SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 30, PLUS OR MINUS <br />HOOKED DOWEL <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAYBE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />ANCHOR <br />W.W.M. AT PERIMETER <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />WHERE THIS CONDITION <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL PER ANCHOR) <br />#5 CONT. TOP & MID OCCURS <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />WITH MIN. 3" COVER <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />6'-0" F. <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF F MORTAR IN BED JOINT. <br />0 OR E J01 DO NOT FURROW. <br />SEALANT <br />S <br />D <br />T <br />r 11T <br />PRE P REINFORCING <br />SS PANEL EINFORC NG INTO PLACE. <br />C <br />- - <br />6 MIN. LAP SPLICE W/ <br />D III I <br />COVER PANEL REINFORCING IT R F F <br />ORC G WITH UPPER HALF 0 MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />- - <br />I I IT- <br />III T <br />SMOOTH. DO NO FURROW. <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />o <br />GRADE <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6" MIN. LAP <br />D °' <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />c�i ° P <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />" z <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />r P <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />\ ' (2) #5 REBAR. (1-STORY) <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />SECTION AT DEEP MONO FOUNDATION <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />REV. 07.28.21 SCALE: 3/4" = V-0" <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />FILLED CELL PER <br />FOUNDATION PLAN <br />iR <br />YP.) <br />THE <br />:S <br />UNACCEPTABLE INSTALLTION <br />DO NOT DO THIS <br />FILLED CELL INSTALLATION <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />BRIG WALL TYPE <br />PER PLAN I I <br />I I <br />F CHANNEL, <br />FASTENED PER <br />NOTE 2 BELOW--L-AF--I- <br />CONT 2X4 NAILED TO <br />BLOCKING w/ 2-12d NAILS (**) <br />#5 REBAR (TYP,) <br />10 <br />*TD. 90° HOOK (TYP.) <br />SCALE: N.T.S. <br />2x SUB FASCIA <br />ALUM DRIP EDGE <br />ALUM FASCIA <br />1-3/4" TRIM PAINTED <br />SS NAIL w/ 5/16" HEAD <br />DIA. @ 24" O.C. <br />CONT VENTED OR SOLID SOFFIT <br />2x BLOCKING NAILED TO TOP <br />CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**) <br />V/-- <br />1G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 16544 R5 FIL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />- CMU w/ T NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />- WOOD w/ (3) 16 GA. 3/4"x1/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />SUB FASCIA w/ 16 GA. 3/4"xl/4" CROWN STAPLE @ EACH GROOVE <br />STRUCTURAL SOFFIT <br />SF01 SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS <br />REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />2kO <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO Z-6" <br />4 * DOUBLE 2X4 SCAB FOR Z-6" TO 4'-0" O.H. <br />Q`NGTN (2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />+ PLYWOOD SHEATHING <br />+ + <br />+ <br />BLOCKING AS <br />144 + REQUIRED TO <br />+ + <br />+ SUPPORT SOFFIT <br />/ CENTER SOFFIT - <br />PRECAST LINTEL <br />SEE ELEVATION <br />FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSIONrM <br />SCALE: 3/4" = V-0" SS <br />QFF QNFFT n9 amn <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8 DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />n <br />3 MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: 3- - , <br />Z <br />O <br />U) <br />2 <br />U_ <br />O <br />W <br />U <br />Q <br />B @ FIRST COURSE <br />2"x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED - <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />---2x BAND JOIST W/ FACE NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAM10KTA @ 12" O.C. <br />w/ (4)1/41 1/2" SDS SCREWS <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO <br />FILL 1st4 COURSES <br />SOLID W/GROUT <br />n <br />d: <br />FOR OVERHANGS BETWEEN OVER 1 112" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />d' <br />OVERHAN y <br />a <br />a: <br />d <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REQ'D. <br />11-0" 51-0" <br />SH <br />SCALE: N.T.S. <br />o . 1*1 Y <br />#5 BAR <br />CENTERED W/ <br />oC 9 H �° <br />° o <br />IN TOP <br />a KNOCKOUT/ N <br />° CHAIR BLOCK <br />MONO FOOTING f <br />.a s ° <br />SIZE AND REINF. PER PLAN - °. . <br />AND SECTION DETAILS <br />CLEAN FILL J .o A. <br />DIRT Z <br />A. ° STANDARD CD90° HOOK N <br />#5 BAR IN <br />FILLED CELL, <br />� 6 <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />)TE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC <br />)NTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />4" SAW CUT <br />-1 LLiu <br />EXISTING FOOTING A SECTION <br />1 SCALE: N.T.S. <br />RETROFIT FILLED CELL DETAIL <br />SCALE: N.T.S. <br />e•a <br />N <br />0 <br />N <br />N <br />< <br />0 <br />0 <br />L <br />=n <br />ccCJ1� <br />o=X <br />N M cm <br />N <br />'ELF <br />dv=� <br />v <br />o u d <br />i � C <br />Q-� <br />N <br />c E <br />a v <br />M <br />N <br />O <br />N <br />co <br />0 <br />M <br />o <br />°ti9A <br />�s <br />LEtv'��e e <br />a i i <br />n '� sr <br />P <br />rd o 0 � •` <br />-, <br />0 <br />(=i t, ,,• t �P ,,fie <br />+�•=dy5e+ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Flo da Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />IN <br />4 <br />E S N <br />M V <br />O N t1D a <br />0 <br />S ID <br />00N LL <br />InU:31 <br />w w <br />N <br />a <br />o_ 0_ <br />6M � w <br />C_j 3aRz <br />- t9 <br />0 <br />—ern 5 O <br />Z <br />L N gO 0 0 <br />r� o <br />'�N(O m W 0 <br />W <br />r rn ¢ F_ z <br />z' <br />co d 0 w <br />� (+') <br />Z V (� H N <br />Z <br />o U ❑❑❑ <br />to <br />M co <br />z N co <br />b � <br />2 <br />CV <br />� o � <br />J <br />V) <br />N <br />M <br />z <br />c� o <br />c13 <br />w <br />° <br />U <br />O—� <br />w o <br />tl�6 <br />�Ln <br />'n <br />v C <br />LU co <br />•.. <br />W <br />j <br />) <br />m <br />� <br />0 <br />� <br />W <br />9 <br />M <br />J <br />� <br />z <br />4 <br />o <br />=o <br />>m <br />co <br />row <br />�o <br />a E <br />co <br />r <br />o <br />o <br />z <br />�_ <br />L <br /><o <br />fly M <br />c_ <br />e <br />¢ o <br />1 <br />W <br />E <br />0)0 <br />Ono <br />>O�Z <br />M <br />a ai <br />zZ <br />Z <br />go <br />a <br />m <br />aE <br />az <br />�3 <br />= H <br />o <br /><, <br />;o <br />IIIIIIIIIIIII' <br />e7 <br />v <br />a = <br />01 <br />zla <br />e0 <br />0 <br />= <br />12 <br />> LO <br />C) <br />d' <br />ca <br />m <br />L. <br />T <br />N <br />o <br />LO <br />Q-3 <br />O <br />N <br />(n o <br />>, <br />N <br />m <br />L0 <br />a--+ <br />o <br />� <br />� <br />O <br />Y <br />M <br />CO <br />CO <br />ca <br />m CD <br />L.n <br />r <br />Q <br />r <br />co^ <br />r <br />CM <br />C4 ce) <br />0 <br />E <br />T' <br />w <br />Z <br />M" <br />cc <br />E <br />2 <br />d <br />U J <br />Q Q <br />J <br />JOB <br />NO : <br />23-02469 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />_ r i I I 1 J_ <br />I ... Ai . II.,1 ,l� I I.TifliPl I III i',,.l.L.J I�I,JIXLIVi�71,IIw IILlutlel,l,-.i..i�m-d, a:,�_ irf�� --r <br />
The URL can be used to link to this page
Your browser does not support the video tag.