My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6330 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6330 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:38:21 AM
Creation date
2/19/2025 12:52:04 PM
Metadata
Fields
Template:
Building Plans
Street #
6330
Location
Beverly Hills Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
4644
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS <br />1 /411 = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />J U N 1 1122 <br />VIRTUAL kEVIEW ASSIST <br />virtual Review Assist, Inc. Oved <br />Plans Review completed and p <br />for compliance v/ith the 2020 <br />pX23 t <br />Edition by Debra Anne Kl <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET c� <br />TRIM--- <br />BASE--- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />110V DUPLEX OUTLET AT 45" <br />COUNTERS <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />AT 12" - TOP PLUG IS HOT <br />MOUNTED <br />HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />® STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-O PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />--� PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />-- CLG MNT PREWIRE - FIXTURE BY OWNER <br />{- SURFACE MNT FIXTURE <br />}- <br />WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - <br />ALTERNATE <br />TUB/SHOWER <br />CANS MAY BE <br />4� <br />50W PAR30 NFL 6" WHITE BAFFLE <br />USED IF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE <br />OWNER <br />�8 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN <br />PREWIRE AND SWITCH <br />cs COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />SMOKE DETECTOR <br />°U-18- <br />UNDER CABINET 18" <br />r-S-18- <br />SINGLE 18" FLUOR STRIP <br />=U-24= <br />UNDER CABINET 24" <br />=S-24= <br />SINGLE 24" FLUOR STRIP <br />=D-24= <br />DOUBLE 24" FLUOR STRIP <br />— U-36 — <br />UNDER CABINET 36" <br />— S-36 — <br />SINGLE 36" FLUOR STRIP <br />— D-36 — <br />DOUBLE 36" FLUOR STRIP <br />S-48 <br />SINGLE 48" FLUOR STRIP <br />D-48 <br />DOUBLE 48" FLUOR STRIP <br />24 <br />24"CLG MNT WRAPPED FLUOR LIGHT <br />48"CLG MNT WRAPPED FLUOR LIGHT <br />9F24:7,9 <br />24" VANITY LIGHTING <br />36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />"IffiZI ELEC PANEL <br />® VACUM OUTLET AT 12" <br />F4CEILING RETURN AIR <br />ES A/C REGISTER <br />® THERMOSTAT <br />1311 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />l <br />W <br />1. = `O 11 U <br />0 cMC m <br />V) <br />N <br />V = Oc' u coa <br />-" - ` <br />M <br />E <br />W O 2 0 <br />O �o Q <br />Z U .- <br />�N <br />W <br />w 10.E <br />N C <br />s=�? <br />L C) 0 <br />C) a <br />w <br />W� W J W m � O <br />F- X <br />Y Z <br />O_ju)O�W <br />_jO <br />0�2 <br />U) 0FQQ0 0zM ¢ So zLL z0www9z0w00mz 6 <br />OZ <br />U) �in anww �Q _, <br />a <br />OO_j<<WtZWZ0/) <br />LL <br />W �f �W <br />OQzis Q <br />OW o ¢LL <br />Q O LL <br />O <br />Z <br />W <br />O� <br />0 cO <br />Q(l)M� <br />U) <br />2rnza. <br />Iti <br />Ln <br />F—W0-M <br />�a2v- <br />Z00 <br />V <br />Z <br />W <br />JC:) <br />O <br />CID <br />I <br />I <br />1 <br />I <br />N <br />o0000 <br />N <br />� <br />O <br />` <br />M <br />M <br />N <br />-- <br />O <br />Co <br />Co <br />O <br />O <br />O <br />N <br />O <br />N <br />O <br />I <br />I <br />' <br />z <br />O <br />co <br />WO <br />O <br />O <br />O <br />O <br />M� <br />Cr <br />} <br />z~ <br />W <br />(n <br />Qz <br />O <br />z(j) <br />`* 0 <br />O <br />W <br />V <br />000 <br />UVC/) <br />� <br />Z <br />owo <br />ara <br />Q <br />Ln <br />= <br />in <br />N <br />O <br />zo= <br />W <br />Q <br />zoo <br />gmm <br />wLL <br />z <br />az <br />ZCC <br />N <br />F G <br />p <br />_Q <br />m <br />z <br />z <br />z <br />w <br />W <br />J <br />0 <br />N <br />LAST PLOT DATE <br />• <br />April 13, 2022 <br />z <br />O <br />I. <br />2ND FLOOR <br />-- <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.