My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6383 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6383 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:43:43 PM
Creation date
2/19/2025 12:52:45 PM
Metadata
Fields
Template:
Building Plans
Street #
6383
Location
Back Forty Lp
Contractor
Lennar Homes LLC
Building Plans - Permit #
6622
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 0 <br />TAPE EDGE OF HEAD <br />WALL FLASHING <br />STUCCO ON FRAME - 7/8" <br />3-COAT SAND FINISH STUCCO <br />ON SELF FURRING LATH ON 2- <br />LAYERS OF WATER RESISTIVE <br />BARRIER COMPLYING WITH <br />ASTM E2556, TYPE 1 (TYP) <br />WALL SHEATHING PER PLAN— <br />SHIIJGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />WEEP SCREED <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL- <br />18 GA HEAD WALL FLASHING <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />SHIIJGLE ROOF PER SPECS — <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8 <br />ROOF SHEATHING <br />PEF PLAN <br />EATL <br />TE: <br />- LATH AND LATH <br />TACHMENTS TO BE OUT OF <br />RROSION-RESISTANT MATERIAL <br />99- 1 1-011 <br />TAFE EDGE OF HEAD <br />WALL FLASHING <br />STL CCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />WALL SHEATHING PER PLAN - <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREE <br />WEEP SCREED <br />HEAD WALL TRIM FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL <br />C014T BUTYL TAPE SEALANT PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLOSURE <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />11- 1 1-011 <br />`v <br />M <br />z <br />00 <br />HEAD WALL <br />0 <br />5_�11%\M <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />TAPE EDGE OF COUNTER <br />FLASHING <br />WEEP SCREED <br />COUNTER FLASHING <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL <br />SHINGLE PER SPECS <br />STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />TAPE EDGE OF RAKE <br />WALL FLASHING <br />WALL SHEATHING PER PLAN_ <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED--__ <br />WEEP SCREED <br />RAKE WALL STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />FIELD BEND PANEL UP 1 1/2" <br />CONT BUTYL TAPE SEALANT 7PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLOSURE <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN <br />v' ROOF SHEATHING <br />NOTE: PER PLAN <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE CONT SELF ADHERED <br />OUT OF CORROSION FLASHING TURN 3" UP WALL <br />-RESISTANT MATERIAL <br />HEAD WALL <br />FLASHING REQUIREMENTS <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />TAPE EDGE OF HEAD SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. > L j <br />WALL FLASHING O ) �--► <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />FIBER CEMENT FIDING 0- O <br />FIBER CEMENT SIDING PER ELEVATIONS AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER O Q O L <br />PER ELEVATIONS WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE C C5 'O �- <br />WALL SHEATHING PER PLAN EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO .� U CD <br />WALL SHEATHING PER PLAN THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. C CU cu C/) <br />SHINGLE WATER N -0 U -0 <br />SHINGLE WATER 00 RESISTIVE BARRIER R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM c 20 .� N <br />RESISTIVE BARRIER OVER FLASHING HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED C sZ C O <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL O <br />OVER FLASHING TAPE EDGE OF COUNTER CC C % -- CU <br />EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE O <br />STARTER STRIP FLASHING UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE M 'p O O <br />00 °0 JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED cn O L- Q <br />CONT SELF ADHERED STARTER STRIP MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE 2 CU !Z <br />CU <br />FLASHING TURN 3" UP WALL COUNTER FLASHING BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT (— -sue .a C%) Q <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />18 GA HEAD WALL FLASHING CONT SELF ADHERED TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />TO EXTEND MIN 8" BEYOND FLASHING TURN 3" UP WALL APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />UNDERLAYMENT ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />Z SHINGLE PER SPECS <br />SHINGLE ROOF PER SPECS R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />00 STEP FLASHING TO INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />ROOF UNDERLAYMENT TO EXTEND MIN 8" BEYOND SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />z TURN UP WALL MIN 8" UNDERLAYMENT z PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF SHEATHING ROOF UNDERLAYMENT TO PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />co <br />PER PLAN TURN UP WALL MIN 8" CO ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />"v "v BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING z <br />PER PLAN EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />6" 61' wit DESIGNED DRAINAGE SPACE. <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE —FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL HEAD WALL RAKE WALL WINSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />R O F TO WALL - SHINGLE TO SIDING ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />BUILDING STRUCTURAL FRAMING COMPONENTS. <br />P 12 ,-o„ W P 13 SELF —ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />TAPE EDGE OF HEAD GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />WALL FLASHING ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />FIBER CEMENT SIDING WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />FIBER CEMENT SIDING PER ELEVATIONS OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />PER ELEVATIONS FOLLOWING LOCATIONS: <br />TAPE EDGE OF RAKE <br />WALL FLASHING 1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />WALL SHEATHING PER PLAN AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />WALL SHEATHING PER PLAN FINISH OR TO THE WATER —RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />SHINGLE WATER SHINGLE WATER FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />RESISTIVE BARRIER RESISTIVE BARRIER SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OVER FLASHING MIN 8" OVER FLASHING MIN 8" OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />011 00 STARTER STRIP <br />°D STARTER STRIP co 1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />RAKE WALL STEP FLASHING TO INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />EXTEND MIN 8" BEYOND FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />HEAD WALL TRIM FLASHING UNDERLAYMENT THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />TO EXTEND MIN 8" BEYOND INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />UNDERLAYMENT FIELD BEND PANEL UP 1 1/2" INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />CONT SELF ADHERED CONT BUTYL TAPE SEALANT PER WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />FLASHING TURN 3" UP WALL MANUFACTURER INSTALLATION RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />lo <br />INSTRUCTIONS FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />/11 CONT BUTYL TAPE SEALANT PER AND SIDES. <br />MANUFACTURER INSTALLATION - 'Z' CLOSURE <br />INSTRUCTIONS co1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />00 STANDING SEAM METAL °° REGISTERED DESIGN PROFESSIONAL. �{ <br />Z CLOSURE ROOF PER SPECS 1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />STANDING SEAM METAL ROOF UNDERLAYMENT TO 1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />ROOF PER SPECS TURN UP WALL MIN 8" 250, FMA/AAMAIWDMA 300 OR FMA/AAMA/WDMA 400. <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />ROOF UNDERLAYMENT TO CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH u <br />TURN UP WALL MIN 8" PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />ROOF SHEATHING ROOF SHEATHING COPINGS AND SILLS. <br />PER PLAN PER PLAN 4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />CONT SELF ADHERED 5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />FLASHING TURN 3" UP WALL 6.6 AT WALL AND ROOF INTERSECTIONS. <br />RAKE WALL HEAD WALL RAKE WALL 7.7 AT BUILT-IN GUTTERS. <br />s <br />3 - <br />ROOF T WALL - STANDING SEAM ROOF TSIDING THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />WP 14 rr- 1 1-0 WP 15 FLASHING AND WATERPROOFING METHODS TO BE USED. <br />JUN 2 7 M3 <br />VR/\ <br />Virtual Review Assist, Inc. <br />Plans Review completed and approve <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />V <br />z <br />J <br />a <br />C <br />CU <br />0 <br />L <br />Q <br />V <br />O <br />L <br />CU <br />m <br />4 <br />SHEET N0. <br />WR2.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.