Laserfiche WebLink
PANTRY <br />4'-3' <br />GFI GFI' <br />6�GFI AT <br />f11�30" A.F.F. <br />TO <br />)ISP <br />GFI Al <br />�- 30" A.F.F <br />5'-8" <br />KITCHEN <br />M <br />GFI. GF <br />A = <br />GFI -10 <br />TILIn <br />12k <br />GF <br />�.l <br />A/C <br />DISCONNEC <br />WP <br />GFI <br />1 <br />0 <br />v <br />I <br />I <br />DINING <br />ROOM <br />� n GFI <br />ELEC O <br />METER <br />ELEC <br />PANEL <br />! TWO CAR GARAGE <br />48 <br />i o <br />GFI <br />GFI <br />110V CLG <br />MNT. i <br />1OUTLET <br />---- ---! — <br />I <br />-------- <br />q II I <br />I 4 I <br />C) <br />I � I <br />I � I <br />i <br />L-------------------I <br />P! <br />HDMI <br />6'-1" 1 <br />LIVING <br />ROOM <br />ql GFI <br />N WP <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /4" = 1'-0" <br />4'-8" <br />ENTRY <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST X FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH — <br />DOOR JAMB <br />DUPLEX 19 <br />OUTLET in <br />TRIM <br />o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />S <br />SMOKE DETECTOR <br />1' <br />-0" <br />MIN. <br />In <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />I*= WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�F. TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />® STRUCTURED WIRE OUTLET <br />-b SWITCH AT 36" <br />co <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-C PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />—fl PUSH-BUTTON DOORBELL <br />-{} CLG MNT LT FIXTURE <br />} CLG MNT PREWIRE - FIXTURE BY OWNER <br />{} SURFACE MNT FIXTURE <br />- WALL MNT FIXTURE <br />NOTE: <br />03 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />06 50W MR16 4" LOW VOLTAGE OWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />`Y- CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CosCOMBINATION <br />DETECTOR <br />C SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />= S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />1 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:M 24" VANITY LIGHTING <br />99-m 36 :rR 36" VANITY LIGHTING <br />4848" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />O EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />GM CHIMES (DELETE W/ INTERCOM) <br />MEMIF MASTER STATION <br />_111116-0 ELEC PANEL <br />® VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />ES A/C REGISTER <br />(T THERMOSTAT <br />M SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />t+ ) <br />A' W t N E <br />L L '0 N O <br />tn M M <br />co U <br />-C t p <br />2 O 2 S <br />N <br />LL1 aN C <br />L o E� <br />F, 0 a <br />W W <br />W <br />0LLi vi w0LU � <br />LU I-Q M 0:�F-z� <br />C� <br />4:02�QOQM<LLV00-J0 <br />aCl) 0 omoomzz <br />Z <br />0 (Aww�w_ <0 <br />a0 <br />J <br />WpiHV5ziwO6w0p¢ <br />OQ o 0 oQZ <br />ILL �¢LL <br />f <br />O <br />O <br />ZW <br />O� <br />D ti <br />0 <br />z <br />c <br />Q W M L0 <br />CL <br />2��� <br />z <br />< w U� <br />W a- M <br />o- 2 T- <br />Z0 <br />Z <br />W <br />WO <br />_j <br />O <br />M1 <br />d' <br />N <br />� <br />Virtu <br />1 Re <br />il1 <br />Plans Revi <br />A s <br />t. <br />for compliance <br />co <br />ith <br />pt <br />the <br />ed <br />nd <br />by Deb <br />qn <br />e, <br />020 <br />a <br />F$ C <br />X 3 <br />® <br />diYi <br />ra <br />N <br />N <br />LO <br />O <br />r` <br />O <br />N <br />O <br />N <br />O <br />O <br />INM <br />O <br />O <br />O <br />w <br />` <br />0 <br />Q <br />N <br />O <br />N <br />N <br />CD <br />Z <br />o <br />r- <br />0 <br />0 <br />0 <br />' <br />O <br />Nto <br />Ix <br />w <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />I <br />i <br />> <br />COLO <br />VJ <br />}~ <br />ZZ <br />O <br />W <br />¢w <br />Z 65 <br />0 <br />^ <br />WOO <br />U U cn <br />LO- <br />i.f <br />OOr< <br />Q <br />Z <br />a—(L <br />F— <br />w <br />LU <br />�--I <br />N <br />ccft w <br />H0 <br />N <br />� <br />z0 <br />on <br />� <br />LLI�� <br />IXO <br />C:)w <br />Q <br />gwx <br />LL <br />Z <br />Z <br />az <br />�z <br />F� <br />OU <br />_p <br />W <br />z <br />z <br />z <br />w <br />W <br />J <br />N <br />0 <br />N <br />LAST PLOT DATE <br />z <br />• <br />O <br />May 5, 2023 <br />J <br />1ST FLOOR <br />ELECTRICAL PLAN A <br />