6393 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6393 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:12:59 PM
Creation date
2/19/2025 12:53:09 PM
Metadata
Fields
Template:
Building Plans
Street #
6393
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5360
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEV. AT 0'4' (8" MIN. ABV. GRADE) (TYP) <br />• 3-1/2" MIN. 2500 PSI CONC. SLAB OVER <br />6 MIL VISQUEEN VAPOR BARRIER <br />• MECH. COMPACTED FILL TO 95% OF <br />MAX. DRY DENSITY <br />• TREAT SOIL W/ TERMITE POISONING OR <br />BORACARE TREATED LUMBER IS AN <br />ALTERNATIVE TERMITE PROTECTION TO <br />SOIL POISONING (TYP) <br />4'-0" L 2'-5" i_ 3'-10" 1_ 3'-9" <br />30'-0" <br />(-) 3-1/2" <br />4'-4" rV � 5'4" <br />2'-4" <br />i❑ - 131 I a - - 0 I❑ <>�0 i❑ 0 <br />F1 _ <br />___---_-- I o m <br />rr ' <br />I II I N o <br />° 0 ° <br />I B I ii I M 2 B <br />S3 <br />I I ii I I <br />I II I <br />p <br />II <br />F_ I I I <br />W I I I <br />J I II I <br />�Q > >I <br />0 <br />�= 0��1 ii I 14 <br />(V Z I 0 <br />A --- N W N m Z----;--�— <br />33 <br />�-- ==LF <br />o-------� <br />II = d II II <br />O II fn I II_ Y NU II I I O <br />-�'. <br />I I I I I O <br />11 I N W <br />II II = I I C3 <br />------------ I J W <br />J I I I O <br />13 II II I ' <br />T7 N <br />9II II I <br />I I I I I I <br />u <br />� 10 I II II I CV <br />-- II II I I Cn <br />II II <br />14 <br />- v L--------- __1L_-----------JI 2'-2 3/8" ---------- ----- <br />PLUMB. <br />6'-31/4"---2'-6"- i-----i7--�--I------------ <br />LAV LAV 8'-5 1/8" 7'-3 3/8 <br />ELEC. CONDUIT SINK/ ELEC CONDUIT o <br />I I � I <br />`r LO <br />Ol <br />� I <br />C) Lot 9 <br />C! I -- L 1 4 ' L-----� <br />--------------------- <br />6 � d- <br />14 I ii I <br />9'-2" <br />-I <br />Cl) —-------- REF.--- <br />- I-� --, --- n -r- - �- -- � <br />II II II ' II _ <br />II I I O <br />L----J L ---- L---I -r ------j <br />" <br />r----_----------- <br />N 20'-6 <br />TUBI <br />17'-7"1 <br />12 u <br />W/C <br />I I I II <br />14'-10" I i 4 <br />LAV I T7 <br />yy� <br />ul <br />---------------------- - <br />---- -- ----- <br />----------------------------- ---- ------ m <br />--------------- <br />- — — — — — — — — - <br />_ - M <br />o �� I 10 11 ill 14 ii `'W �? <br />I I <br />S3 iIl <br />I I� II <br />I K LIT 21-0 <br />S3 i AW SHER <br />v I ELEV <br />(-) 0'-4" I 7 0 <br />_ U_ <br />0� I <br />m I a I it B 1 A <br />g o 3'-5" o 0 <br />co , <br />---- i 1i <br />N a' <br />(D I o <br />A <br />I <br />O N <br />d 1'-4" 3'-0" V-8" 3'-8" '-0' <br />I <br />B I g 6'-0" 4'-8" <br />3 I <br />o I o <br />14 v a' <br />q I I 3 B <br />L, o m 0 L i J r7 <br />V-8" <br />16'-0" <br />19'-4" <br />30'-0" <br />FOUNDATION PLAN (ELEV A <br />1 /4" = 1'-0" <br />1'-8" <br />10'-8" <br />0 <br />to <br />ELEV <br />0'-3 1/2" <br />0 <br />H oo <br />d- <br />FOUNDATION LEGEND: <br />NOTE: <br />BUILDING SLABS SHALL HAVE CONTROL JOINTS IN <br />ACCORDANCE W/ AC1224-3R <br />= FILLED CELL W/(1) #5 VERTICAL <br />W = FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB <br />A = FILLED CELL W/ (2) #5 VERTICAL <br />O = FILL CELL TO (1) COURSE ABV PIPE (NO REBAR) <br />.'= (2) 24" #5 REBAR PLACED DIAGONAL AT CORNERS <br />i <br />®= WINDOW OPENING ABOVE <br />PLUMBING NOTES: <br />FBC 7TH EDITION (2020) PLUMBING SECTION 604 <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WATER -FLOW RATE. <br />PUBLIC FACILITIES LAV 0.5 G.P.M. <br />PRIVATE FACILITIES LAV 2.2 G.P.M. <br />SHOWER HEADS 2.5 G.P.M. <br />VTR LOCATIONS ARE APPROXIMATE AND MAY <br />CHANGE DUE TO JOBSITE CONDITIONS. <br />LICENSED PLUMBER TO VERIFY AND HAS THE <br />AUTHORITY TO CHANGE AS NEEDED. <br />O KEYNOTE LEGEND <br />KEYNOTE <br />ANNOTATION <br />1/2 DP X 9 1/2 WIDE RECESS <br />1 1/2" DP X 8" WIDE RECESS <br />3� <br />1 1/2" DP X 13" WIDE RECESS <br />4� <br />ICE MAKER LINE <br />SINK - KITCHEN <br />REF <br />WASHER <br />8� <br />W/H <br />9� <br />UNDER SLAB ELECTRICAL CONDUIT <br />10 <br />LAVATORY <br />11 <br />WATER CLOSET <br />12 <br />TUB <br />13 <br />36" x 60" SHOWER PAN <br />14 <br />CONTROL JOINT <br />15 <br />42" x 42" A/C CONCRETE PAD <br />0 FOOTING LEGEND <br />TAG <br />TYPE <br />SIZE <br />REINFORCING <br />THICKEN EDGE <br />8" x 8" DP <br />(1) #5 CONT. <br />© <br />MONO FTG <br />16" x 20" DP <br />(2) #5s CONT. <br />© <br />PAD <br />24" SQ x 16" DP <br />#5s 6" O.C. EA. WAY <br />A � � <br />\P,�A <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved' <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />6`J J <br />C, o"c <br />ARPj <br />305 <br />sr <br />. <br />1 ` F <br />N L '-0� ° <br />} <br />C7 <br />U <br />) <br />M <br />-0 O CO <br />° <br />m <br />A' <br />E �E - <br />_ M <br />t <br />O <br />W <br />Q <br />O o <br />` <br />0 <br />Q <br />.N <br />.0 <br />U�� <br />N <br />} <br />V <br />w 0 <br />W <br />L <br />© E <br />70 <br />C) <br />' O�D <br />am <br />— F- CL <br />N <br />N <br />O <br />N <br />LO <br />h <br />LO <br />O <br />O <br />L2 <br />Q <br />z <br />W <br />O <br />0 <br />7 <br />0 <br />z <br />Q <br />W W'0 <br />❑j U w0H <br />LL< <br />it O'� <gezzl <br />W <br />_t- <br />QcyX-'Z0oo0>C1H6'tE00M'0z <br />�T_.L`U0 -j <br />U, <br />_o <br />nw OfznWa°WwZW�Q°U' <br />Q <br />Q < <br />ZEn <br />¢��O <br />Ow <br />F� <br />�w0U_ <br />LL_ Q <br />o F LL. <br />Ili <br />O <br />O <br />z CV <br />0 <br />(n O <br />p�Mo <br />J Lq <br />U) L.L ti <br />W <br />L0 <br />�'- (yi <br />U Q � <br />Z <br />W Z <br />Wo <br />J C) <br />INK <br />INK <br />(0 <br />C)o <br />o <br />N <br />N <br />o00 <br />N <br />N <br />ch <br />N <br />N <br />O <br />C)N <br />' <br />z <br />O <br />Lo <br />WN <br />> <br />C� <br />C� <br />I <br />I <br />I <br />I <br />Lo <br />W v) <br />zQZ <br />O <br />W <br />�--+ <br />O <br />W <br />U <br />W O O <br />UUzij <br />L <br />I-- <br />O <br />Z) z >_ <br />OW0 <br />�— Q <br />C)I— <br />Z <br />0-ofa <br />W Q <br />u / <br />WF- <br />W r <br />H~O <br />� <br />r-I <br />_ <br />z o = <br />}_U) <br />. . <br />N <br />W <br />Q <br />W <br />O <br />��_Z) <br />ZWO <br />Z <br />U <br />Jz`L <br />°z <br />Z <br />� <br />�� <br />U <br />Q <br />0 <br />0 <br />n <br />W <br />z <br />z <br />w <br />W <br />J <br />C)N <br />O <br />C) <br />LAST PLOT DATE <br />O <br />• <br />July 15, 2022 <br />Z <br />-4-J <br />0 <br />.6- <br />� <br />MONOLITHIC <br />FOUNDATION PLAN A <br />