My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6393 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6393 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:12:59 PM
Creation date
2/19/2025 12:53:09 PM
Metadata
Fields
Template:
Building Plans
Street #
6393
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5360
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DICONNECT <br />JP <br />FI <br />ELECTRICAL PLAN (ELEVATIONS A & B <br />1 /4„ = 1'-0„ <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />OCT 2 8 <br />Virtual Review Assist, Inc. `/ <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />200A INDOOR PANEL <br />7 <br />CENTER <br />01 #15 copper to lights & outlets <br />NEMA 1 <br />00- #12 copper to 20 amp ckts <br />200 AMP <br />00#10-2 copper to WH <br />00- #10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Li <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />TYPICAL 150-200 AMP ELECTRICAL <br />RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH- <br />4 1/2" <br />DOOR JAMB <br />DUPLEX <br />OUTLET <br />TRIM - <br />BA <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />11QV DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />�- SWITCH AT 36" <br />E 3 WAY SWITCH AT 36" <br />-cam 4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />--0 PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />-'f}- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4� 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />CU-18= UNDER CABINET 18" <br />CS-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />F,F24-_;9 24" VANITY LIGHTING <br />FF,7F 36 :R;R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />)� MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />WAI CEILING RETURN AIR <br />E3 A/C REGISTER <br />THERMOSTAT <br />SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />nN, <br />N L E <br />or-, 0 <br />W L <br />❑ _a, <br />5 <br />to <br />V Q <br />to <br />D O 2 o <br />° `� o Q <br />` <br />V w Q! <br />coo E <br />(D <br />L. <br />O °0 ro <br />LLi L <br />w WP W _j w2�0 <br />Io-¢ Z QW <br />zU ¢<-)JO�00-1O <br />¢UO <br />f- <br />D0Z� <br />WLuOOWOOmpZ <br />�Z��Q <br />¢ <br />5 U <br />(j)T_Z <br />a v)LU <br />0ULZ0IL <br />I<W< <br />wF¢pOZ cn <br />LL�w0O <br />U <br />¢pw 21-2w2U¢ <br />Q <br />¢oL¢ <br />0 ¢w <br />LL <br />O <br />O <br />Z N <br />O� <br />W <br />z <br />Q � C) O <br />Q 'A (M r__ <br />CL <br />2(n�l` <br />z <br />< W < <br />M_ <br />00 <br />z10 <br />v< <br />W <br />J O <br />O <br />I <br />I <br />I <br />I <br />1 <br />I <br />O <br />o <br />N <br />o <br />N <br />��C) <br />N <br />N <br />N <br />N <br />N <br />o <br />N <br />`� <br />a> <br />o <br />o <br />— <br />o <br />I <br />I <br />1 <br />I <br />z <br />O <br />NLuu <br />L0 <br />>00 <br />o <br />o <br />l <br />l <br />l <br />l <br />�^ <br />} <br />zF- <br />vJ <br />Qz <br />O <br />Zw <br />0 <br />W <br />U <br />000 <br />W"�, <br />O <br />Dzj <br />Oro <br />Z <br />0-Wa <br />0 <br />= <br />W2a <br />v <br />� <br />~~O <br />T� <br />OOM <br />W�� <br />z�� <br />O <br />Q <br />Z <br />�WLL <br />v_ <br />U)z <br />Q <br />F� <br />J <br />OU <br />O <br />a- <br />Of <br />z <br />z <br />z <br />z <br />w <br />W <br />J <br />O <br />N <br />O <br />o <br />LAST PLOT <br />DATE <br />■ <br />July 15, 2022 <br />z <br />�' <br />O <br />J <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.