CORNER OF <br />HOME <br />GARAGE SIDE <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />n, RIDGE LINE <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />IDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ + <br />+++ <br />+++ <br />+ + <br />+ + <br />+++ <br />+++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />++ <br />+++ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />r <br />J <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 118" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., cinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Yg" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical lad transfer =1900 pii max along load bearing wall. <br />Lad bearing wall must stack <br />over squash=20 blocks and <br />Non -stacking walls wall or beam below.* <br />require additional <br />consideration. Check <br />local building ;or--20 <br />1/16" <br />code for appropriate <br />10'-0" details in One 10d box <br />TANK -LESS W/H areas=20 of high sinker <br />lateral bad. nail each side <br />at bearing. <br />5'-0" _ <br />STUB -OUT FOR "' <br />GAS METER O <br />N <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) -12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />1 USP HTW20 OR 3 16d TOENAILS <br />2" X 12" 16" O.C. <br />19'-3" <br />1) USP HTW20 OR 4 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />V-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" it Odl nails at 6" n c <br />Provide adequate bearing <br />for each lapped joist. <br />°doa"S SECTION @ INT. BRIG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL <br />STD. 90° HOOK BOND BEAM <br />CO <br />w <br />. I. ........................ ...... <br />Cr <br />< STD. 900 <br />— CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />— - BAR <br />I <br />1� <br />#5 CONT. <br />........... <br />...... <br />... 11 <br />. . <br />FROM <br />E <br />FOUNDATION <br />TO HIGHEST <br />�f — <br />���—I <br />BOND BEAM <br />VJ <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />J <br />OTHERWISE SOLID <br />I <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION <br />@ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. Small 2" min. <br />2" max ) <br />gap <br />• � 4 max. <br />Clinch nails <br />when <br />possible <br />Tight fit U \ <br />2x4/Plywood/OSB web stiffener <br />required when indicated or <br />- Hangers with side nailing. <br />- Hangers with sides not containing <br />top flange of joist. <br />- Birdsmouth cuts. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when lad bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c, for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />to <br />rk <br />6" A 1y" ROUND HOLE MAY 6" 6" <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1 2 <br />DO NOT CUT HOLES <br />LARGER THAN 1h" <br />ROUND IN <br />CANTILEVERS. <br />8 <br />T-U" <br />V-1" <br />1' 2' <br />1'2' <br />1' 3' <br />1-3' <br />i' T' <br />1"1" <br />2'-4' <br />2-9' <br />3 T <br />3' T' <br />Any 1fi' joist 12 <br />T-0" <br />V-1" <br />1'2' <br />i' 2" <br />i' 3' <br />i`3' <br />2-4' <br />2-11" <br />3' T' <br />42' <br />4'2' <br />6-4- <br />Span 16 <br />1'-0'' <br />1"" <br />1'2' <br />1' 2" <br />1' T' <br />2'6' <br />3'-2' <br />3'-10" <br />4'-9r' <br />S T' <br />6--C <br />T 2- <br />20 <br />1'-U" <br />1"" <br />V-2' <br />T 2" <br />2-0" <br />3-0" <br />4-0" <br />4-10" <br />5-11" <br />6'11" T-11" 9-11" <br />24 <br />1'-0" <br />V-1" <br />1'2' <br />1-3" <br />2'-6" <br />3' T' <br />4'-9' <br />S 10" <br />T2' <br />8'-4" <br />9-6' <br />10'-9' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %' ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />/When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />2" min. <br />4" max. <br />WEB STIFFENER <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90S <br />11- / " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />Plumbing <br />Joist <br />Woist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install fight to top flange. <br />Joist hanger <br />Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install fight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D depth <br />N <br />I -JOISTS BUCKETS <br />N.T.S. <br />USP <br />MU( <br />5/8"e <br />THRU <br />BOLT <br />Uc <br />Mt <br />R TRUSS <br />'OP PLATE <br />LC <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />W FASTENERS <br />TYPICAL HTA 20-18 / HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM � a <br />SEE PLAN FOR •• e . • <br />FOUNDATION INFO ` 4' '. <br />STEM FOUNDATION <br />rGRADE r-REINF. SEE PLAN <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />GRADE <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF <br />SECOND RT16 <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d A 1/2" NAILS <br />UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE PLUMBING LINE <br />PENETRATION <br />• q d ..4 <br />—------------—oa----a <br />--------------- <br />io Z • v • • <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />a a' d a <br />ea4,MG <br />\ 4 la <br />\, a v a a / <br />\ Y A / <br />SEE FND. PLN. <br />SIZE & REINF. <br />0� <br />Z Cq <br />c§ <br />Z� <br />Z <br />Q <br />I <br />n.- <br />kn <br />4-J w <br />� p <br />U <br />"O w <br />La <br />10 <br />V <br />U <br />m� <br />as_8 <br />8, <br />00 <br />U <br />�Y <br />rn <br />it <br />ao <br />$v <br />Q <br />add <br />A' <br />B D.IQ <br />NCBDC <br />0 <br />44 <br />N <br />.. <br />N 1; <br />a A .�; <br />pp <br />Z <br />_J <br />• C* <br />4z.. <br />CA 0 C� <br />ti <br />9 <br />r> 1 <br />Y' '. <br />cif ,.�,; <br />❑ <br />To the best of ngineex�# ' jt***tiation, and <br />belief, the structu f Amp1 an s contained <br />within these drawings comet a Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />CD <br />Z r4 <br />0 <br />4-0 CD <br />LA M O <br />z <br />M <br />d -0 <br />0 <br />i <br />Q LL. <br />a <br />tY(:�)QCo <br />Q Co <br />zf° <br />W <br />J <br />mi <br />d" <br />W Il <br />Z Fr n: <br />ei �oa <br />2gz�8a� <br />` Z Z Z U <br />CD <br />ZO <br />W ® <br />CD <br />r-1 <br />N <br />�3 <br />oC <br />.69. <br />O <br />"o <br />z <br />Q0,4 <br />d <br />o� <br />UJ <br />W <br />LU <br />> <br />J <br />`� <br />ty 0 <br />Iii!g <br />O <br />CD <br />0 <br />u_ <br />�.— <br />Z <br />CD <br />M <br />a <br />LU <br />0 <br />.. <br />Z <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: FFLORES <br />VERSION NO. <br />1525 <br />JOB N0: 17-3664 <br />SHEET NO. <br />SN 1 <br />