My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6503 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6503 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:13:04 PM
Creation date
2/19/2025 12:54:19 PM
Metadata
Fields
Template:
Building Plans
Street #
6503
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18786
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH'" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />12 <br />MANUFACTURER. <br />5.9� **ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />8' RIDGE VENT THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />FIBERGLASS SHINGLE OR LOCATION PURPOSES. <br />CONCRETE TILE PER <br />COMMUNITY SPEC (SEE Exterior Covering <br />STRUCT.) R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />T.O.P. <br />— _ — _ — _ — _ _ _ _ _ _ _ _ corrosion -resistant <br />All Lath and lath attachments shall be of <br />HDR. materials. Attached per ASTM C 1063. <br />— — — — — — — — — — — — — — <br />— — — R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />12 coats when applied over metal lath or wire lath and shall be not <br />AV 5.0� z z less than two eats when applied over masonry, concrete. <br />Q R703.6.3 Water-Reslsidve Borders. <br />O� 1 H3 SH 0 Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />O O 12 shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />F.FL. <br />-------------_ _ _ _ _ _ _ _ _ ---------------------------------------------------- ---------------- <br />the water -resistive barrier is directed between the layers. The <br />—----------12------------------------------------------------------------- <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />T.O.M. _ _ _ 5.0� accordance with R703.2. <br />— — — -- — <br />_ HEEL _ WEEP SCREED 2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />@ GAR. _ _ <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />o q Exterior lfcn• Intersection ochimneys ss on her masonrYcontructions withbo <br />TEXTURED FINISH frame walls. <br />1'-8" • Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />F.FL. <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />LEFT ELEVATION - B Attic Ventilation be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential al R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />SCALE: 1 /4" = V-0" but no more than 50% of the required ventilation is provided in the upper portion ol <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by save or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer SpeaficatIons) <br />• RIDGE VENTS - 15 80. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS - 7 $0. IN. OF NET FREE AREA / SO. FT. <br />FIBERGLASS SHINGLE OR *I Howinot e pproved ven vented soffit is provided due to fire protection, the contractor shall use <br />the <br />CONCRETE TILE PER • LOMANCO DECK AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />COMMUNITY SPEC SEE"Formula: (Sq.FtSaffBNeeded) x7=(Sq.In. Needed) /9=(UnewFtorr�-arNeeded) <br />( • O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />STRUCT.) "Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Arraurd of OMa & verve needed <br />12 <br />5.91 8' RIDGE VENT <br />4' OFF -RIDGE VENT <br />T.O.P. <br />- <br />_ HDR. <br />z Z = <br />0 4 23 SH o o cc <br />O O 12 <br />3.01 12 5.01 F.FL. <br />--------------------------------------------------------- _ _ _ _ ______ --------- <br />WEEP — — — — — — — — — — <br />WEEP SCREED _ _ _HEEL <br />---------------------------------------------- - <br />@ GAR. <br />0 <br />TEXTURED FINISH 00 <br />2'-0" a op <br />F.FL. <br />RIGHT ELEVATION - B <br />SCALE: 1/4" = V-0" <br />CD rn <br />zg <br />z <br />Q <br />J <br />a <br />Z <br />4--i w <br />�U — <br />0 LUl <br />Eg <br />o <br />V) <br />U <br />mMM <br />$ <br />oso <br />U. <br />U <br />a �, <br />CS ar. <br />Ho <br />A1 <br />B D. <br />".C.a.o.0 <br />If <br />11 <br />f--R <br />`t v 6.i i i,f,r, <br />rri <br />♦ 0.. <br />' —9 <br />✓ <br />L4 <br />N <br />i <br />To the best eer of the Engins ge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1 <br />O <br />O <br />z N <br />0 <br />.a+ CD <br />� M O <br />M <br />Q 'f°v L^ <br />4) <br />o Ln <br />Q L � <br />d <br />`rn <br />a c. 00 <br />�� <br />30. <br />z M <br />WUJ <br />0 <br />z� <br />LUoo <br />asa <br />8�2 <br />Z Z <br />o yLu <br />84 W <br />uJ <br />zr�,r <br />J <br />O <br />LA <br />N <br />(n <br />,Ln—I <br />W <br />�3 <br />Ing <br />t090 <br />0 <br />z <br />E~z�� <br />W <br />— <br />_ <br />CL <br />F. <br />zgf9rzz <br />W W 0 a 0 <br />is—?LU <br />ac� <br />pz=d <br />i <br />W <br />z <br />LU <br />.. <br />�, <br />.. W <br />J <br />g <br />z <br />a W <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />1525 <br />JOB NO: 17-3664 <br />SHEET NO. <br />4 <br />■ <br />
The URL can be used to link to this page
Your browser does not support the video tag.