My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6503 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6503 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:13:04 PM
Creation date
2/19/2025 12:54:19 PM
Metadata
Fields
Template:
Building Plans
Street #
6503
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18786
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�Cuj, I, i " - ",4_L 1.1 ._ :. I_.__ L I. __ "i 1-1__.._1: 111�ll114 �� <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />MAIN <br />O <br />200 amp <br />150 amp <br />POWER CO. FEED —� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />NEMA1 <br />200 AMP <br />copper to lights & outlets <br />copper to 20 amp das <br />.2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />---------------------------J <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combirmtion Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in comer counters. <br />I ELECTRICAL KEY I <br />---------------------------- <br />DUPLEX CONVENIENCE OUTLET <br />L <br />RECEPT. <br />I I <br />I <br />DUPLEX OUTLET ABOVE COUNTER <br />12 <br />\/fj J I WIC I <br />FOR ALA <br />SYSTEM <br />I I <br />11—� <br />V1 <br />�_ <br />W P <br />WEATHERPROOF DUPLEX OUTLET <br />` /V <br />S.D. <br />_ _ _ <br />I I T_O_SW_ <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />_ITTCH <br />WNSTAIRS <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />1 <br />DUPLEX OUTLET IN FLOOR <br />----------------- <br />L <br />HN <br />220 VOLT OUTLET <br />/ I <br />j <br />WALL SWITCH <br />I <br />� / <br />$3 <br />THREE-WAY SWITCH <br />I <br />94 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />1 <br />O <br />RECESSED LIGHT FIXTURE <br />< <br />I// <br />LIGHT FIXTURE WITH PULL CHAIN <br />MASTER <br />TRACK LIGHT <br />I <br />I <br />I <br />I <br />BEDROOM <br />FLOURESCENT LIGHT FIXTURE <br />® <br />EXHAUST FAN <br />O <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />]M ELECTRIC METER <br />ELECTRIC PANEL <br />—� <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />` / J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I j <br />I I <br />I I <br />I I <br />L — — — — — — — — — — — — — — — — — — — — — J <br />----------------------------------- <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2nd FLOOR ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />QDm <br />Z <br />Z <br />Z <br />Q <br />J <br />Apollo <br />U) Z <br />^Ln ID <br />W <br />N <br />LU <br />OU-1(1003/) <br />U <br />LU <br />o <br />091 <br />$Ooo <br />6 W■— <br />��M <br />_ <br />LOLL <br />Q <br />LO a� <br />g <br />Al <br />B D. <br />N C B�DC <br />_ J <br />o <br />� N <br />fw � <br />V N <br />coo <br />Z ao <br />z <br />g r- Z° <br />r' LL N j <br />M <br />We�'LL <br />W L <br />a <br />Z Q cti <br />� <br />IL Z 1 2 <br />W °'�• <br />a'i <br />-j o <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1 <br />O <br />O <br />Z C4 <br />0 n <br />N M O <br />Z <br />M <br />M LLO <br />0. <br />W0In <br />a. <br />Z <br />F- <br />f L 00 <br />Z M <br />W <br />J � <br />Ctr <br />wl <br />Z a. <br />� <br />Z <br />1= <br />a <br />C�78FZ <br />0 �W <br />O® <br />O <br />,-1 <br />Ln <br />N <br />Ln <br />ril <br />ORIt <br />Z <br />�1 z <br />J <br />0 <br />$gQoii <br />LU <br />F— <br />w <br />N Ups <br />� <br />CD <br />o <br />�0UUj <br />M U~ <br />W <br />~ <br />OJ <br />Z W <br />J <br />g <br />Z <br />W <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />1525 <br />JOB NO: 17-3664 <br />SHEET NO. <br />6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.