My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6518 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6518 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:17:01 PM
Creation date
2/19/2025 12:55:16 PM
Metadata
Fields
Template:
Building Plans
Street #
6518
Location
Beverly Hills Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />x <br />a <br />rn <br />cs <br />0 <br />�p <br />J <br />00 <br />UT <br />S <br />e <br />J <br />oo <br />0 <br />I <br />to <br />0 <br />c9 <br />Q <br />N <br />E <br />E <br />0 <br />N <br />ti <br />0 <br />�I <br />i <br />a <br />0 <br />Lo <br />19 <br />a <br />N <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />NEMA1 <br />150 AMPr <br />200 AMP <br />D lights & outlets <br />D appliances and GFI <br />DWH <br />Range <br />HVAC <br />'V <br />so=zro <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UND <br />i nLedKI <br />SERVICE BYPOWERCO. <br />AINTERSYSTEM <br />e Cu Ground <br />11IJ <br />BONDING <br />NDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan Is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />5)4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�_o <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />© <br />EXHAUST FAN <br />1 ` <br />,QI <br />EXHAUST FAN/LIGHT COMBINATION <br />KD <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PER <br />PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />UQ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />fit 2ry <br />AV ).Q DTI, <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />vt_vtvn I LtJ [ILVt_r 1 nVL_L <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />VERIF( METER <br />I OrATInN WITH <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: Y4'=1'-0" <br />tV <br />o <br />U <br />'y' <br />0 <br />w co r— 0 <br />-- m <br />r-i C W d <br />'n co o <br />•vNi <br />� q p <br />m 'r Y c <br />o = <br />,= C <br />� o <br />0 <br />N <br />N <br />0 <br />N <br />c� <br />0 <br />To the beat of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N N T <br />7 US <br />�NO� <br />m n <br />C J <br />U. <br />9k tJi. <br />tL w <br />tL <br />10 <br />3 <br />a <br />ax <br />Z �a� <br />_ 8 <br />SRC 1 <br />Wc"O' <br />�0�cc <br />m w <br />Z;Z <br />Q <br />C"I <br />= N OU <br />00 <br />W <br />E <br />CD r <br />Z N 2G <br />dd <br />Z � <br />Z <br />J <br />d N <br />- N <br />V <br />LL <br />� <br />4--+ r„ <br />� w <br />Ln LLJ <br />Ln <br />U <br />' W <br />3 <br />Q <br />c <br />o <br />M <br />w <br />Z <br />78 <br />_j <br />0� <br />E <br />oLL <br />=® <br />�E OV <br />i— <br />�� <br />0 <br />oa <br />wg <br />o � <br />Z <br />pO E <br />CV <br />.= <br />wo <br />w Z <br />¢� <br />t <br />C <br />�o <br />o <br />M <br />~� <br />c <br />ZNgW <br />—� <br />° <br />g z <br />(V <br />w <br />g <br />?p <br />W <br />�w <br />N Z <br />wy6 <br />IIIIIIIII� <br />[] <br />�V <br />w <br />za <br />of <br />a t- <br />i;3 <br />O <br />L1� <br />rn <br />Q <br />C9 <br />co <br />J <br />T <br />vJ m <br />m <br />L0 <br />QI <br />O N <br />O <br />O <br />N <br />) <br />0 <br />T <br />Q � <br />r <br />0 <br />Z <br />ro <br />Z <br />E y <br />1n <br />c <br />a <br />E <br />U <br />JOB <br />NO: 22-06458 <br />SCALE : AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.