ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />---------------------------------------------- <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />-the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />j4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />❑ PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a TELEPHONE (OPTIONAL) <br />TV TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />119 ELECTRIC METER <br />_lQ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />METER <br />MO <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />NEMA1 <br />200 AMP <br />copper to lights & outlets <br />copper to 20 amp ckts <br />.2 copper to WH <br />.3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />INOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE I <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />SWITCH FOR -� <br />DISPOSAL IN <br />CAB. UNDER SINK <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />3Fl DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />PENDANT <br />31 GFI LIGHTS OVER <br />�\ / I ISLAND <br />2'-0" 2'-0" GFI <br />KITCHEN <br />'3::2 X FFL. <br />OPTIONAL LIGHTING <br />SCALE: %4'=T-0" <br />/C <br />Ij ALT jl <br />AC PAD I <br />II )( <br />L— — =J <br />AC PAD <br />DISCONNECTWP <br />HB — tM GFI <br />ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />`I V 1 1 It I <br />_ PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />CLUJ <br />r}LO <br />�J T <br />zM <br />Z Cc <br />Z <br />a <br />o <br />a <br />z <br />``nn <br />V <br />W <br />t <br />4--J w <br />� 0 <br />'U - <br />W <br />O <br />~ <br />O <br />U <br />l— E <br />$ <br />Q M <br />LO '0 M <br />Q CO 0 <br />_ <br />U y <br />U_ co <br />0 Cc <br />CL <br />0 <br />Q <br />00 <br />`�aS <br />i Q o <br />A ' <br />B ®m <br />N-C -B�D-C <br />a� <br />11 <br />�04LQ <br />N <br />� CV <br />i0 <br />.n o <br />o <br />Ci o oNo <br />o = <br />z z <br />�Z/ I� M O~�1 Z M <br />LL <br />& O <br />LL LL. <br />LL <br />IlY ui <br />W C U. 0 <br />w Lu <br />a d d <br />N <br />14 <br />j5o � <br />ii� Ecp <br />ca <br />IL W Q �aM <br />N Q 0 <br />—j g <br />Q� LQLJm 0 <br />❑ ❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1 <br />O <br />C4 <br />Z <br />0 .2 � <br />i>V)roO <br />„M <br />Q M Ln <br />a cn•�� <br />Ln <br />QCLL <br />Z,-I <br />a .-. <br />a 3 a <br />Q ()0 <br />� <br />Z M <br />. <br />W O <br />W <br />J � <br />0 <br />WLL0 <br />w Z l- in ii <br />twit- �in0 <br />00 ZZ <br />Z>-�U�� <br />Z <br />2 - UJ <br />� :5 W 22 _j <br />a 0 in <br />3 <br />o"F-aOLLJ <br />ZO <br />O <br />ri <br />Ln <br />N <br />�1 <br />LP1 <br />ri <br />C <br />LU F- <br />/ / <br />4.1.. <br />�J <br />Z <br />Z cYc,�,� in <br />w 0 0& <br />v <br />z <br />00 `C <br />��zmo <br />w <br />O�� <br />J <br />ZO�0 <br />� <br />Z <br />N CL <br />� <br />�� <br />� <br />N <br />�$ �8 <br />Q <br />t�L w0tLZQ <br />O U <br />O <br />U) <br />OX Z <br />O R W <br />'Z <br />MO <br />a. <br />30- <br />j LL <br />OT­q <br />U. <br />LL <br />Z.. <br />..E <br />J <br />Z <br />W <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />5oll <br />JOB NO: 17-1397 <br />SHEET NO. <br />3 <br />