Laserfiche WebLink
AMC ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion o <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(D (0 <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />VENTED SOFFIT 4$ SQ. FT. -CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN <br />(D <br />- <br />(Values to be verified with Manufacturer Specifications) <br />• <br />RIDGE VENTS 15 SQ. IN. OF NET FREE AREA /LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />............... ......... ......... • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />co <br />*If not enough vented soffit is provided due to fire protection, the contractor shall use the <br />following approved vents: <br />•.::� • LOMANCO DECK -AIR (Shingle Roof)- 9 SQ. IN. OF NET FREE AREA / FT. <br />-Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = (Unear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA I VENT <br />• �; I **Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />.I <br />o <br />o <br />:.1 <br />•:jj� <br />�i <br />�1j ZONE-3 <br />•�•� <br />7.7. ATTIC SPACE <br />••7 <br />wl <br />3366 SQ. FT. <br />+;d <br />:i� <br />•'•I <br />•'.1 <br />•'•1ii <br />11 :• <br />•o. <br />•i <br />LL. +'� ILL <br />;.1 <br />fl 'l <br />LLLIL­ •� LL <br />O 0 <br />Ln <br />W '•'LU <br />•I t— <br />Z Z <br />l <br />•��ii1 <br />••�ii1 <br />••�I <br />A <br />l <br />..1 <br />.'� <br />•��I <br />•.+� •;� <br />•+ " ILL �— Q <br />� o <br />.� <br />A W <br />••� <br />:� <br />: <br />VENTED SOFFIT 9 SQ, FT. <br />' VENTED SOFFIT 4 SQ. FT.L VENTED SOFFIT 4 SQ. FT. ROOF PLAN -A_ <br />SCALE: %4"=1'-0" <br />ATTIC VENTILATION CALCULATIONS - A <br />ATTIC VENTILATION REQUIRED UPPER VENTILATION PROVIDED <br />1/150 Rule 1/300 Rule Ridge Vent Amt <br />(No Upper Ventilators (Must Provide Upper Ventilators) (Ft.) Off -Ridge Amt. <br />Req.) <br />Total Ventilation <br />ATTIC <br />Provided by <br />SPACE SQ. IN. of SQ. FT. SQ. IN. of Upper <br />SQ. FT. Total SQ. of ventilation to Ventilators <br />ventilation <br />of vented IN. of vented be provided SQ. IN. of SQ. IN. of (See Elev) <br />required soffit ventilation soffit by upper Ventilation Ventilation <br />needed required needed ventilators <br />L00 — <br />Main 22.0 3.0 <br />Floor 3366 3231 462 1616 115 808 744.0 <br />(Zone 3) 330.0 414.0 <br />0.0 0.0 <br />0 0 0 0 0 0 0.0 <br />••� <br />0.0 0.0 <br />0.0 0.0 <br />0 W <br />0 0 0 0 0 0 0.0 <br />ol- <br />W <br />0.0 0.0 <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />Wj 0 7— -y o <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL . IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />:%71 -------------- <br />VENTED SOFFIT <br />� c LU <br />Z <br />Q O <br />0 <br />O <br />n <br />LLU <br />n <br />W cod <br />.}.J LLi <br />O <br />rcc <br />Lo <br />V <br />o <br />U d M <br />r.L9 C t6 Cl) <br />i— EE M <br />— cg O o0 <br />U y D Y I::- <br />0) CL 8 <br />,o o v <br />Q rn d <br />A1 N C B D C <br />M <br />•V J <br />= 4�'G�1-Mi� C - L.L <br />W �NM� <br />LL00 <br />oti � CD <br />W aNaM� � �'o <br />a� 0 m o <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />Z N <br />O a� r\ <br />I <br />M In <br />z ON <br />> <br />+�MO <br />M <br />fl. <br />Q E 00 <br />z� f° <br />WJ 110 <br />d- <br />oZ <br />W LPL o <br />zt —`Cn <br />w � a <br />Q W G , <br />UI—gsno0 <br />Oz aU <br />Z <br />>Uj <br />LJJ <br />- <br />� U i Q <br />a <br />ZWI—Z <br />�p�aC JW <br />V o <br />OUt—�SzO <br />J <br />rl <br />Ln <br />rl <br />win00'Cle, <br />Uj <br />� z O �~z0°O <br />O�wUJ 5Iw- <br />0 uZ,O��O�Z <br />ft3 z A Uw�Z00 <br />Q F- <br />1 �wOwza <br />O Q ��aQoo <br />LL JOz<C <br />z � � O � <br />> �-- Z 0 <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: ERAND <br />VERSION NO. <br />100 <br />JOB N0: 17-1799 <br />SHEET NO. <br />4 <br />� c LU <br />Z <br />Q O <br />0 <br />O <br />n <br />LLU <br />n <br />W cod <br />.}.J LLi <br />O <br />rcc <br />Lo <br />V <br />o <br />U d M <br />r.L9 C t6 Cl) <br />i— EE M <br />— cg O o0 <br />U y D Y I::- <br />0) CL 8 <br />,o o v <br />Q rn d <br />A1 N C B D C <br />M <br />•V J <br />= 4�'G�1-Mi� C - L.L <br />W �NM� <br />LL00 <br />oti � CD <br />W aNaM� � �'o <br />a� 0 m o <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />Z N <br />O a� r\ <br />I <br />M In <br />z ON <br />> <br />+�MO <br />M <br />fl. <br />Q E 00 <br />z� f° <br />WJ 110 <br />d- <br />oZ <br />W LPL o <br />zt —`Cn <br />w � a <br />Q W G , <br />UI—gsno0 <br />Oz aU <br />Z <br />>Uj <br />LJJ <br />- <br />� U i Q <br />a <br />ZWI—Z <br />�p�aC JW <br />V o <br />OUt—�SzO <br />J <br />rl <br />Ln <br />rl <br />win00'Cle, <br />Uj <br />� z O �~z0°O <br />O�wUJ 5Iw- <br />0 uZ,O��O�Z <br />ft3 z A Uw�Z00 <br />Q F- <br />1 �wOwza <br />O Q ��aQoo <br />LL JOz<C <br />z � � O � <br />> �-- Z 0 <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: ERAND <br />VERSION NO. <br />100 <br />JOB N0: 17-1799 <br />SHEET NO. <br />4 <br />