My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6551Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6551Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:12:35 AM
Creation date
2/19/2025 12:56:26 PM
Metadata
Fields
Template:
Building Plans
Street #
6551
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18615
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />MAIN <br />0 <br />200 amp <br />150 amp <br />NEMA 1 <br />200 AMP <br />)pper to lights & outlets <br />)pper to 20 amp clas <br />copper to WH <br />copper to Dryer <br />or 4/0 SER Alu <br />Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />il 250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser DiagraM (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI'E; (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Mono)dde Protecdon: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSIIUL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination AJarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in comer counters. <br />I ELECTRICAL KEY I <br />DUPLEX CONVENIENCE OUTLET <br />FPI:� <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />?_4 <br />FOUR-WAYSWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />#P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />TI <br />2' <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08,2%94 <br />WM. <br />1 2- VTR <br />M <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />LAV. <br />SWITCH FOR <br />DISPOSAL I N CAB. <br />I L__ � _111 DEDICATED <br />EXHAUSTFAN iL�O I LL <br />0 1 RECEPTACLE <br />EXHAUST FAN/LIGHT COMBINATION OUGH-IN FOR MICROWAVE <br />0 FOR OPT. GFJ RANGE HOOD <br />2x4 FL.E IGHT I PER SPECS <br />ELECTRIC DOOR OPERATOR (OPTIONAL) KITCHEN <br />LVIIJ <br />Fr_1U_1 CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) n, <br />SMOKE DETECTOR L _H <br />SMOKIE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />/> <br />ROUGH -IN FOR OPT. CEILING FAN <br />_\�4k <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ \> <br />OPT. CEILING FAN <br />G� <br />(1) PHONE LINE, (1) DATA PORT <br />OPTIONAL LIGHTING <br />SCALE: )/4"=V-0" <br />Uj <br />LLI <br />Z <br />0 X <br />>_ LU <br />u_ <br />CC 0 <br />Uj 0 <br />> _j co <br />IRRIGATION GFI <br />@ 44" A.F.F. <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />DEDICATED <br />RECEPTACLE <br />FOR MICROWAVE <br />RANGE HOOD <br />PER SPECS <br />1st FLOOR ELECTRICAL P <br />SCALE: Y4"=V-0" <br />CD <br />V) <br />C—J) <br />0 ULJ <br />E <br />Lh <br />vi <br />0 <br />0 <br />cn <br />CD <br />M C) <br />C14 <br />LU <br />E <br />0 C13 <br />a Cn <br />02 VO 121 <br />" 'C C14 <br />02, <br />Elm 6 <br />:F; LL CO <br />SO <br />0 <br />a CD <br />0 <br />'t <br />0).� 0 <br />8 D <br />r-- <br />C14 <br />cc CF) <br />�2 LO <br />G3 to <br />Es r_ C14 <br />6 C5 <br />C�) C-4 Z <br />Mr 4W 2 CP <br />LL <br />LL_ <br />N <br />am <br />LWLI <br />Lu <br />a- a- LU <br />> 0 <br />< CL_ <br />a- <br />g <br />Z 0 Coo) <br />(4 Z) <br />Of <br />0 <br />M C-4 <br />a <br />Z �11 E <br />c, B <br />IL <br />M M <br />C3 <br />W <br />_j <br />0 <br />Co 1— <br />El 0 0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seat. <br />Z <br />0(i) <br />14 4_j C) <br />Ln I _= <br />> V) <br />—4 C:) <br />Z <br />- cel <br />4-J <br />0. (n <br />0 <br />Ln <br />r-L LL <br />Z <br />M <br />CL 00 <br />E <br />Z <br />Z <br />Uj F- <br />W <br />_j 0 <br />Milli! <br />0 <br />a Z <br />LU LL Q <br />W Z <br />LL, a <br />in 0 <br />0 Z<C) <br />Z <br />I- Z Z Z <br />LU Z <br />L-9 <br />0 V) <br />00 <br />. 04 <br />.0 <br />F_ Z @I <br />C:) <br />LU <br />C:) <br />In <br />Ln <br />_j <br />Z <br />Z Q 0 <br />LU 0 0 Q 0� <br />0 <br />< <br />1< < <br />L) OPJ- �Z; 2 <br />9 LZU: <br />Z <br />=5 0 <br />CY- -� Z <br />fo <br />Z <br />Uj <br />UJI 0=0 <br />du!) _j 0, <br />�j 6 <br />_j <br />8 �- 5 <br />fl!90- <br />< <br />0 LL Z a- <br />< <br />� ,e <br />( <br />t U X 8 <br />N 0 <br />>7 <br />00 <br />T-1 <br />a I P�� Zo <br />0 Z < <br />C:) <br />_j Se Ly <br />C) <br />re) <br />Z <br />UJ <br />> <br />Z <br />:5 <br />Z <br />0 <br />LLI <br />SCALE AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: FGUZMAN <br />VERSION NO. <br />1122 <br />JOB NO: 17-1800 <br />SHEET NO. <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.