ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />---------------------------------------------- I <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42"AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with thE <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for thE <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of thE- <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriatE, <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with ari <br />exit alarm complying With UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wail directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The Width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counte, <br />tops and 18" for sinks and ranges installed in corner counters. <br />I - ELECTRICAL KEY I <br />K)-- <br />DUPLEX CONVENIENCE OUTLET <br />I Z±, <br />FEPI:: <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />4-P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />rD� ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br /></ \> <br />OPT. CEILING FAN <br />G9 <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 — <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Doper to lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />i Alu <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />----------------------------- <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />----------------- <br />L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - j <br />2nd FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />0!�M <br />Z ce) <br />M <br />Z (D <br />Z <br />ZV) (D <br />(1) <br />U—) <br />�_j LLJ <br />U <br />LLJ <br />0 <br />F_ <br />E <br />0 <br />C) <br />LU <br />E <br />a) ccel <br />CD M <br />C ca ce) <br />T :S c-, <br />020 <br />= LL co <br />CD <br />(D <br />_4 <br />0 j:�' <br />(1) 0 <br />U) 0 V <br />< 0 <br />c)) <br />q CL <br />d) < 6 <br />A <br />MID. <br />N-C-13 D C <br />U11 <br />ce> <br />LO <br />Its <br />tAZ MO- Z0 zz <br />6 6 <br />_j _j cs <br />MW V 1.42 2 T or- p <br />mu_— <br />U_ .1 <br />--j <br />(0 N <br />C� <br />r-u- <br />LU Uj <br />U < '11. <br />Z 0 <br />2� <br />ro— 0 <br />E <br />0 <br />M <br />cV <br />LL <br />04 Ce) <br />. . 0 <br />0 <br />U.J <br />* W 0 <br />C) <br />0 M <br />El El 1:1 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />C) <br />C:) <br />Z 11714 <br />0 cu r-, <br />0-4 4-J <br />U) — <br />:3 <br />> U-) M p <br />4-r N <br />U-) M Lr) <br />0 <br />a) — Ln <br />< " U. <br />rL <br />Z <br />Q� 0 00 <br />< E <br />Z <br />Uj <br />W <br />_j CD <br />ko <br />Milli! <br />0 <br />ce cle <br />ED Q_ <br />� E a, <br />LU <br />Ln 0 0 <br />0 Z < 6 <br />Z >_ <br />op 0 CL <br />Z <Z U Z <br />Z Z Z <br />LLJ Z <br />W <br />Lu <br />U <br />0) <br />.8 <br />C, <br />U, LU C14 <br />Z <br />Q. 0 <br />LU I Z <br />tZ <br />Lr) <br />r_j <br />117�4 <br />Ln <br />_j <br />LLI o _<j <br />LLI W �-_J: <br />cle n <br />Ce <br />Z <br />cc <br />LUNHOW <br />0 <br />< <br />< <br />P tru;,'Z�! ---oj 2 <br />Z <br />_j <br />O—UJ— <br />nomo <br />Z <br />ED <br />CL <br />LOU _j 8 <br />_j <br />> <br />Ln <br />< <br />OLLZ< <br />>— <br />r4 <br />cy Z < <br />U) Z <br />� <br />0 <br />C) <br />uj <br />CL LLJ <br />l.— <br />C) <br />0 <br />Z <br />LLI <br />> <br />. . <br />Lu <br />Z <br />Z <br />0 <br />:5 <br />W <br />SCALE AS NOTED <br />PLOT DATE 12/7/2012 <br />TECH: FLORES <br />VERSION NO. <br />15n25 <br />JOB NO: 17-1426 <br />SHEET NO. <br />6 <br />