My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6587 Paden Wheel St
Zephyrhills
>
Building Department
>
Building Plans
>
6587 Paden Wheel St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:04:57 PM
Creation date
2/19/2025 12:58:47 PM
Metadata
Fields
Template:
Building Plans
Street #
6587
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18306
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />)pper to lights & outlets <br />)pper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />I Alu <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />�44GROLJNDING <br />BONDING <br />WIRE <br />TERMINATION PER � WITH CODE APPROVED <br />NEC 08, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />3" VTR <br />kitchen 44" AFF <br />-III <br />bathroom 39" AFF <br />_III 3" VTR <br />I <br />laundry room 36"AFF <br />exterior waterproof 12" AFF <br />1.5" VTRIII ( I <br />garage general purpose 42" AFF <br />range 2" AFF <br />II I 1 <br />I \ I <br />i <br />2. All trim plates & devices to be ganged, where possible. <br />I I <br />3. Electrical switches to be at 42" centerline above finished floor. <br />I I I I SHWFR <br />I <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />t/0 I I 3„ TU <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />I I I <br />WC <br />installation & sizing of all electrical, wiring & accessories. <br />I I <br />�3" <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />I I <br />„ <br />SIN I 3" 2 <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />I ( <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />I 3" <br />2" <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />HANSON <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />BOX <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />TUB <br />WC <br />31- 3" <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />3„ <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction smoke detectors <br />or shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />PLUMBING <br />RISER- <br />is not acceptable. <br />13.12. <br />All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />BE VERIFIED WITH PLUMBER <br />when the door or window are opened.. <br />/ <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />/ <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />— <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />\ <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />\ <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />GF <br />\ <br />IC7 <br />- <br />DUPLEX CONVENIENCE OUTLET <br />KITCHEN <br />I <br />- DUPLEX OUTLET ABOVE COUNTER <br />I� <br />j GFI <br />W P WEATHERPROOF DUPLEX OUTLET�� <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />IZ <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />- <br />rci, <br />h SPECIAL PURPOSE OUTLET <br />1I <br />X <br />DUPLEX OUTLET IN FLOOR <br />II <br />IGFI <br />220 VOLT OUTLET <br />Ll <br />Ll <br />` <br />` <br />I � <br />WALL SWITCH <br />I <br />$3 THREE-WAY SWITCH <br />/ <br />/ <br />IGFI <br />I E) <br />/ <br />2X4FL. <br />i 4 FOUR-WAY SWITCH <br />/ <br />$R RHEOSTATSWITCH <br />- /J <br />CEILING MOUNTED LIGHT FIXTURE <br />QGFI QGFI <br />WALL MOUNTED LIGHT FIXTURE <br />-III 3" VTR <br />I� <br />I <br />I <br />I /! IKITCH�N <br />DBL.I (SINK I <br />SINK i I I <br />I <br />I <br />I <br />2„ I <br />SINK <br />K] <br />3„ ---/ - <br />SCALE: NTS <br />ORECESSED <br />LIGHT FIXTURE <br />SPEC3 & 4 KITCHEN <br />4-P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />- <br />TRACK LIGHT <br />SCALE: %4'=V-0" <br />�{ <br />FLOURESCENT LIGHT FIXTURE <br />® <br />EXHAUSTFAN <br />- <br />EXHAUST FAN/LIGHT COMBINATION <br />i <br />/ <br />/ <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />'OPT. DEN <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />/ <� 'ROUGH <br />-IN <br />/ <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />FOR OPT. <br />S b <br />a <br />TELEPHONE (OPTIONAL) <br />FAN/LIGHT <br />/ <br />® <br />TELEVISION (OPTIONAL) <br />- <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />- <br />O <br />THERMOSTAT <br />o <br />I I \ <br />• <br />M <br />ELECTRIC METER <br />\ <br />11 � <br />ELECTRIC PANEL <br />BAA3 <br />-� <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />I <br />I <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />DEN OPTION <br />C J <br />OPT. CEILING FAN <br />� <br />(1) PHONE LINE, (1) DATA PORT <br />SCALE: %4'=V-0" <br />2" <br />J TUB <br />WC <br />AC PAD <br />GFI <br />DISC.4-1 9 <br />------------------------------------ <br />LA Al /'' "B <br />MASTER — — <br />NOOK <br />\� BEDROOM / \�� ��'j INSTALL LIGHT <br />ROUGH -IN / <br />I - - 7 �, 10 FOR OPT. - <br />1 I l�� ��� FAN/LIGHT <br />II ALT II `ROUGH -IN <br />I AC PAD I FOR OPT. kfGHT AS <br />WP / PER SPECS <br />FA/LIGHT GFI <br />-v------- ---- <br />I \ I <br />1< <br />v v� / \ _ <br />I <br />I <br />622" 4 3" IGFI <br />DEDICATED R EPTACLE OR I <br />F M I LY / � � sPE O AVERANGE HOODGI�IER <br />F1 jGFI <br />SWITCH FOR <br />DISPOSAL IN j <br />I RF1 J I I <br />/ OF BAR BACKSPLASH <br />o <br />�� ��� I I IGFI <br />GFI _ FOR OPT. <br />N / LI CFI <br />/ FAN/LIGHT <br />- ✓ \` G`I/� <br />d -OP <br />KIT HEN IGFI <br />RECEPT. _+ <br />FOR ALARM = \ I / <br />. BATH SYSTEM <br />I GFI = -�--- --- <br />GFI GFI <br />WICAk---------- <br />O r r <br />DINING <br />_--- <br />FI PENDANT / / LIVING <br />o / AS PER <br />SPECS / <br />— <br />'� <br />,0`�BA 2 \\\ / <br />3 3 / <br />II I <br />BEDROOM o <br />------ / <br />i LAU <br />LIGHT BFFFFFSROOM 4 <br /><� � I AS PER I I \ <br />ROUGH -IN / SPECSFOR OPT. /O PT. D E N <br />FAN/LIGHT\ / IN <br />AHU , I �� �� <br />ROUGH -IN <br />_ - S.D. \ ' FOR OPT. <br />I / GFI FAN/LIGHT <br />W.H. A.F.F. / / \ A. 44 CH <br />A.F.F. 1 <br />LU t J <br />/ — — <br />ZZ r - " --i �\-----�--- <br />�O�FOYER <br />°a —L I / II <br />� 0 = -, U GARAGE \ / I \ \ o <br />II C.M 0 <br />m LL � LIGHT AS/ / I O \ <br />Fr U PER SPYCS o GARAGE <br />LU <br />j w / LIGHT AS <br />o PER SPECS <br />GARAGE <br />BA 3 <br />DOOR GARAGE <br />� <br />GFI GARAGE I \ <br />- - - - - - - - - - - - - - - - DOOR 1 1 <br />GFI DB & GFI TO S.D. <br />------------- ------ <br />o VE ALIGNED DB <br />ERTICALLY W ,� <br />ENTRY I I �,• �- — <br />IRRIGATION I j o \ ENTRY <br />GFI I \ _ _ LI_GH_T_A_S _ _ <��> <br />@ 44" I PER SPECS ROUGH -IN <br />A.F.F. I I FOR OPT. <br />I <br />FAN/LIGHT <br />HB <br />BEDROOM 3 <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />ELECTRICAL PLAN <br />SCALE: %4"=V-0" <br />UI "' <br />zM <br />0 <br />0 <br />z(.0 <br />z� <br />Q <br />o0_ <br />t� z <br />O <br />Q)N <br />4—J W <br />� p <br />'U <br />— <br />W <br />O <br />�- <br />(n ZD <br />o <br />O O <br />U <br />W <br />a)M <br />CM ECf Cl) <br />E`2 'O M <br />-0 <br />0 <br />Ooo <br />tLL00 <br />U(D <br />C <br />0ao <br />Y <br />Q rn <br />to o � <br />CL <br />rnQ o <br />A' <br />NC-B -D-C <br />Gfl <br />N to <br />o rA N <br />. � <br />f� o N o) N <br />V p N <br />6 O <br />Z Z <br />Z W ao c N <br />-L. J <br />ILL. IA_n'rMo <br />) �— <br />W aaC3 N <br />, <br />wa- <br />a <br />UQLL�'o <br />YO 0 'd• Q <br />Q IY <br />.w <br />n Y I N N <br />n <br />m m <br />LL Z Z�rnw <br />WaCD N� <br />CD ce) <br />Q <br />�LU <br />LU <br />LO �U <br />U m <br />To the best of the Engineer's knowledge, information❑ and❑ <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />ON <br />Z <br />0 � n <br />>�ro <br />M <br />Q () I L^ <br />Z00 <br />QLL <br />Q <br />CL <br />Q <br />Z E <br />M <br />WJ <br />C) <br />Oz <br />W LLLO <br />z u, zWG� <br />UI -gNOO <br />oZ>.zQU <br />z> <br />a Q30� <br />wF-Z <br />U a LU <br />LU LU, J <br />0 to <br />0V)0CY0 <br />U � N <br />~aOzOO <br />d" <br />��w <br />O <br />rl <br />LnILL! <br />0 <br />LU <br />Zw <br />0Ll_u 0 0 <br />o � <br />-� <br />Z <br />O J <br />? C <br />z <br />�1 <br />LL <br />LU <br />¢ V <br />> <br />LUW <br />J <br />N Q <br />$o o2 <br />O U <br />62 LLj Q <br />QQ�0� <br />'� <br />�/� <br />V 1 �y <br />W <br />E� p z <br />Q <br />T� <br />�aw <br />a~� <br />Z <br />p <br />U. V <br />LU <br />LU <br />I-- <br />Z <br />H <br />� <br />a W <br />SCALE : AS NOTED <br />PLOT DATE : 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />100 <br />JOB NO: 16-6652 <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.