Laserfiche WebLink
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1 . Cut, fold up & temporarily secure weatl <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and Seal with tape <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />s <br />DO NO' <br />BOTTO <br />F <br />ANG <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />NOT USED <br />Scale: NTS <br />'in WEATHER <br />/E BARRIER & <br />�ARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING <br />BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING <br />NSHING <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-V BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />3/4"-1 BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED <br />THRESHOLD OF DOOR AN <br />UP JAMB 6". USE LIQUID N <br />OR EQUAL WEATHER PRC <br />SECTION -A (SEE DETAIL WP( <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />STALL SELF -ADHERED <br />ASHING JAMB & HEAD <br />ASHING, SEE <br />ANGEDWINDOW <br />EE DETAIL WP01) <br />_LF-ADHERED FLASHING, <br />(TEND A MINIMUM 6" <br />mRTICALLY FROM <br />)TTOM OF <br />SELF -ADHERED FLASHING <br />PATCH <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0. 6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />Q <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF <br />NEEDED IN CORNERS <br />THROUGH SELF -ADHERED <br />FLASHING <br />RUBBERIZED RUBBERIZEF, ACOUAl -r <br />ADHESIVE <br />ASPHALT ADHESIVE <br />SELF -ADHERED FLASHING <br />SCORED <br />RELEASE PP <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />7 <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />0 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 feIt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R7 03.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more ofthe <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMAMDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />4. Continuously above all projecting wood trim. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.01 9-inch (No. 26 GaIv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBCR703.2 <br />Detail Instructions <br />Refer to the number marked as in each detail that corresponds to the numbered items in the list of <br />(D <br />instructions below: <br />1 . Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (16" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />M-01 -M-10 4 <br />&M <br />P <br />A <br />WP07 WP08 WP09 <br />NOT USED <br />NOT USED <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1 063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />/0'_� WEEP SCREED DETAIL <br />11-.� SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTM C 1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Starnpede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0 <br />Ce) <br />0 <br />ID <br />a <br />;7 (0 <br />Z <br />< <br />Z <br />L/) 0 <br />U-) <br />Lij <br />0 <br />LLJ <br />0 <br />0:� <br />L/711 <br />E <br />0 <br />L/) F-- <br />CD CINI <br />tM co <br />U_J <br />0 <br />0 <br />M co <br />0 'r- 04 <br />aE <br />-r ai <br />.2 C) <br />r- U_ 00 <br />0) <br />C5 r� <br />CL CD <br />< 0 <br />0) <br />0 <br />8 D, <br />Tw` <br />/r <br />ce> <br />C,4 <br />to LID <br />LO r- <br />Cc, C4 <br />� C, C'J <br />0 0 <br />CD Z <br />Co <br />Z U1 :23 Co r C4 <br />r.- t.L 0 <br />U <br />. . <br />N. -�- I <br />LU <br />LLI LU <br />.N <br />W U <br />Z -:5 <br />0 ra W. < <br />Z <br />C� Z-) <br />U1 .20113.2 <br />LL <br />M <br />. <br />Z Z I cc <br />0 C,4 <br />LLI 0 co <br />< <br />_J <br />0 <br />Lu <br />ca <br />El 0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />C:) <br />Z r_4 <br />0 cu r--. <br />14 <br />1 4 4-J C:) <br />V) <br />Z <br />> C:) <br />Lr) M Ln <br />-2 <br />L_ 1- <br />0 N <br />a) - Ln <br />L_ LL <br />Z <br />OL <br />U>- fa <br />CL 00 <br />< <br />E <br />Z fu <br />Z <br />UJ C:) <br />W <br />_J C:) <br />0 <br />C)� - <br />LU U_ 0 <br />Z U) <br />LU Z <br />U 0 0 <br />0 >. Z < 0 <br />Z Z 0 0. W <br />Z <br />< <br />2 Z Z Z <br />Z � � Z <br />E2 :5 Lu 0� - <br />0>- W U 0 Lo <br />=D 3: U 0 <br />o(I)a WO <br />00 <br />U �5 LLj F4 <br />Z <br />C:) <br />fy) <br />0 <br />LU Z <br />L4 <br />C:) <br />T__4 <br />r_. <br />Lf) <br />U) <br />(-4 <br />(%4 <br />Lr) <br />< <br />T__q <br />UJ <br />ZW <br />LU <br />< Z U 0 <br />0 <br />0 <br />Z <br />LU 0 0 0 <br />U uEl - -2 <br />,71 M <br />0 Z <br />E <br />Z <br />Z <br />U_ <br />5 UXJ <br />LU LU C <br />U Z 0 0 <br />LU <br />0 <br />< U <br />> <br />0u_ <br />0 a- <br />rr <br />UJI <br />� � p X 0 <br />=) =) �. on <br />OC) <br />R <br />0 2: 0 <br />'0, U_ <br />Ln Z Z <br />< <br />0 <br />C:) <br />re) <br />LLJ <br />LU <br />< a. UJ <br />(=) <br />I-_ <br />U_ <br />Z <br />LU <br />. . <br />F- <br />Z < <br />> <br />0 <br />3: <br />Z <br />SCALE AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: FFLORES <br />VERSION NO. <br />106 <br />JOB NO: 16-6650 <br />SHEET NO. <br />W P <br />