ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO, FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER _71 <br />NEC 08, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC, <br />Dipper to lights & outlets <br />3pper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />: Alu <br />------------- ---------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser DiagraM (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1 . Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine, Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY I <br />lz� <br />FI#F <br />Ow.p. <br />$3 <br />?4 <br />$R <br />+P.C. <br />, V, <br />rD-] <br />FC-H] <br />El <br />FTV1 <br />FTV 2 <br /></ <br />E73 <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKEICARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W1 ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />2" VTR <br />BL. <br />CIO k� �l <br />KITCHEN ISINK <br />SINK W/ STUDOR <br />2" VTR I 1 .1 1 <br />1 1 3" — WC I <br />2' <br />3" TLIB 3" <br />SINK 3" SHWR <br />r- , 1 1 2" 3" —1 1— 1.5" VTR <br />TUB WC 1 2' 1 1 3" <br />1 3" 1 <br />SINK <br />3" HANSON BOX <br />WC <br />TUB 4" <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />111117 <br />.7. GP <br />.7. GFI 2 X4 FL. <br />DEDICATED <br />RECEPTACLE FOR -,.@I <br />MICROWAVE RANGE GFII <br />2 X4 FL. <br />HOOD PER SPECS <br />:7 <br />GFI <br />SWITCH FOR <br />DISPOSAL <br />— UNDER <br />CNTR TOP <br />PENDANT <br />LIGHTS OVER <br />ISLAND <br />OPTIONAL LIGHTING <br />SCALE: Y4"=V-0" <br />4" <br />ALT. <br />I A/C I <br />PAD I <br />L <br />Z <br />0 <br />rr <br />Lu <br />Lu <br />LL _r <br />12� F_ <br />LIJ <br />A/C PAD <br />DISCONNECT <br />WID <br />GFI <br />P-10 r-r_m w_- ._1 <br />SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />ELECTRICAL PLAN <br />SCALE: Y4"=T-10" <br />0 LO <br />Z m <br />Z (D <br />Z <br />0— <br />Z <br />V) (D <br />(1) <br />C-n <br />4-J, LU <br />0 <br />U <br />0 LLJ <br />E <br />0 <br />W co <br />V) <br />M <br />.2 CD <br />C14 <br />C) <br />LU <br />CD CI) <br />0) co <br />cc M <br />E <br />0 <br />0 <br />-0 cl) <br />0 T: C14 <br />20 <br />= ILL 00 <br />1:5 - 00 <br />00) <br />(on fz- <br />8 <br />< 00) <br /><CL <br />BD <br />N-C-B D-C <br />!�2 LO <br />M <br />(.0 Lo <br />LO r— <br />CR - Cj <br />C'j <br />00 Z <br />Z W 60 <br />a? ro <br />U <br />1.. 01 <br />Ix 'C", <br />N <br />LLI <br />LIJ LU <br />a <br />LL <br />W <br />0 -rm <br />Zj3 �t <br />0 <br />-L- 9 <br />W 04 <br />to 2 -M <br />LL <br />Z Z -1 <br />Lu 40 NE <br />0 M <br />_j r_ <br />It <br />LO 6 0 <br />IX LU <br />(if <br />6 CQ <br />El E]I <br />Tothe bestofthe Engineer's knowledge, information,and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />Z 17.4 <br />0 CU r4, <br />�­11 4-J C:) <br />Ul %D <br />C:) <br />> r') <br />-4 C:) <br />0 N <br />Z <br />< 1`0 Ln <br />CAI 0 <br />a) — Ln <br />- LL <br />Z <br />3- CL 00 <br />< - N-0 <br />Z�:E <br />Z <br />Uj C:) <br />W <br />_j C:) <br />0 <br />W 02 Z <br />LU LL <br />Lu Z <br />Lu M j <br />Lu <br />U F- U) in 0 <br />0 Z <br />0 fL <br />Z U X <br />I =-- Z LZ, Z <br />Z <br />0 rL: Lq <br />Lu <br />00 <br />0 to <br />U C) <br />8 Ce CD <br />=2 LU N <br />CD <br />�_Rcz@ <br />Z <br />1170 <br />Lq <br />CD <br />Ln <br />r1*4 <br />0;� <br />Lu i_- <br />W;% �he <br />Z U <br />LU 0 0 0 <br />c) <br />U UJ 0 <br />F_ <br />0 Z U- <br />Z <br />Z - 2,: 0 rr <br />CY-- Z <br />Z <br />LU <br />UJI a 0 <br />0 <br />U <br />> <br />_3 <br />Lu '711 <br />UJ 0 u- Z <br />Z 0 < <br />< < 0 <br />>- <br />oo <br />r*4 <br />Cy u <br />n"Z� <br />0 <br />re) <br />_j <br />a. <br />0- �< X <br />C:) <br />r-4 0 <br />< <br />Z <br />.. <br />.. Lu <br />LU <br />> <br />0 <br />Z _j <br />:� <br />Z <br />LLJ <br />SCALE AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: FLORES <br />VERSION NO. <br />106 <br />JOB NO: 16-6650 <br />SHEET NO. <br />3 <br />