REVISION SUMMARY <br />1, LL IL -1 i <br />NO. DATE <br />1 9.13.21 <br />A.B. <br />Anchor Bolt <br />Abv. <br />Above <br />Adj. <br />Adjustable <br />A.F.F. <br />Above Finished Floor <br />ALT. <br />Alternate <br />Bm. <br />Beam <br />B/Beam <br />Bottom of Beam <br />Brg. <br />Bearing <br />Cant. <br />Cantilever <br />Cir. <br />Circle <br />Cig. <br />Ceiling <br />Ci <br />Control Joint <br />Col. <br />Column <br />Cont. <br />Continuous <br />Dbl. <br />Double <br />Dia. <br />Diameter <br />Ea. <br />Each <br />E.W. <br />Each Way <br />Elec, <br />Electrical <br />Elev. <br />Elevation <br />E.O.R <br />Engineering or Record <br />Ext. <br />Exterior <br />Exp. <br />Expansion <br />F.B.C. <br />Florida Bldg. Code <br />Fin. Fir. <br />Finished Floor <br />Fir. <br />Floor <br />Fdn. <br />Foundation <br />REVISION DESCRIPTION <br />DOOR MOVED AT BACK LANAI <br />ABBREVIATIONS <br />DESIGNER <br />NJ <br />Fir. Sys. Floor System <br />PSF <br />Pounds per squate foot <br />F.O.M. <br />Face Of Masonry <br />P.T. <br />Pressure Treated <br />Ft. <br />Foot / Feet <br />Rad. <br />Radius <br />Ftg. <br />Footing <br />Req'd. <br />Required <br />Gaiv. <br />Galvanized <br />Rm. <br />Room <br />G.C. <br />General Contractor <br />Rnd. <br />Round <br />G.F.I. <br />Ground Fault Interrupter <br />S.F. <br />Square Ft. <br />G.T. <br />Girder Truss <br />SHT <br />Sheet <br />Hdr. <br />Header <br />S.L. <br />Side Lights <br />Hgt. <br />Height <br />S.P.F. <br />Spruce Pine Fir <br />Int. <br />Interior <br />Sq. <br />Square <br />K/Wall <br />Kneewall <br />S.Y.P. <br />Southern Yellow [line <br />L.F. <br />Linear Ft. <br />Thik'n. <br />Thicken <br />Mas. <br />Masonry <br />T.O.B. <br />Top of Block <br />Max <br />Maximum <br />T.O.M. <br />Top of Masonry <br />Min <br />Minimum <br />T.O.P. <br />Top of Plate <br />M.L. <br />Microlarn <br />Trans. <br />Transom Window <br />Mir. <br />Mirror <br />Typ. <br />Typical <br />Mono <br />Monolithic <br />U.N.O. <br />Unless Noted Otherwise <br />N.T.S. <br />Not to Scale <br />Vert. <br />Vertical <br />O.C. <br />On center <br />V.L. <br />Versalarn <br />Opn'g. <br />Opening <br />VTR <br />Vent through Roor: <br />Opt. <br />Optional <br />W <br />Washer <br />PC. <br />Piece <br />W/ <br />With <br />P.L. <br />Parallarn <br />W.A. <br />Wedge Anchor <br />PLF <br />Pounds per linear foot <br />Wd <br />Wood <br />Pit. Ht. <br />Plate Height <br />WP <br />Water Proof <br />TERMITE SPECIFICATIONS <br />SECTION R318 PROTECTION AGAINST TERMITES <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED <br />PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED <br />METHODS OF TERMITE PROTECTION LABELED FOR USE A PREVENTIVE TREATMENT TO NEW <br />CONSTRUCTION (SEE SECTION 202, REGISTERED TERMITICIDE). UPON COMPLETION OF THE <br />APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE <br />ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS <br />THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE <br />PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." <br />NOTES: <br />1 . METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "LIQUID <br />BORATE OR BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE AND <br />PRODUCT APPROVAL DATA MUST BE ON FILE WITH THE BUILDING DEPARTMENT. <br />2. PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED <br />PORTIONS OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION <br />3. OPTIONAL BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. <br />- -NOTICE TO BUILDER AND ALL SUBCONTRACTORS- - <br />IT IS THE INTENT OF THE ENGINEER LISTED IN THE TITLEBLOCK OF THESE DOCUMENTS THAI THESE <br />DOCUMENTS BE ACCURATE, PROVIDING LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY <br />ATTEMPT HAS BEEN MADE TO PREVENT ERROR. THE BUILDER AND ALL SUBCONTRACTORS ARE <br />REQUIRED TO: <br />1 . REVIEW ALL THE INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE ENGINEER ARE NOT RESPONSIBLE FOR ANY PLAN ERRORS, <br />OMISSIONS, OR MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE ENGINEER <br />PRIOR TO CONSTRUCTION. <br />2. SHALL STRICTLY OBSERVE ALL APPLICATION CODES DURING THE COURSE OF CONSTRUCTION <br />INCLUDING ALL STATE, CITY, AND COUNTY BUILDING, ZONING, ELECTRICAL, MECHANICAL., <br />PLUMBING AND FIRE CODES. CONTRACTOR SHALL VERIFY ALL CODE REQUIREMENTS PRIOR TO <br />COMMENCEMENT OF WORK. <br />3. THE ARCHITECT / ENGINEER SHALL NOT BE RESPONSIBLE FOR SAFETY PROCEDURES, THE MEANS <br />AND METHODS OF CONSTRUCTION, TECHNOLOGIES, OR THE CONTRACTION TO CARRY OUT THE <br />WORK IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS OR RELATED CODES. <br />4. THE FRAMING PLAN SHOWN INDICATES THE'TRUSS SYSTEM" AND IS THE RESPONSIBILITY OF THE <br />TRUSS SYSTEM ENGINEER (DESIGN PROFESSIONAL OF RECORD). THE TRUSS DESIGN ENGINEER <br />(DELEGATED ENGINEER) HAS FINAL, RESPONSIBILITY FOR EACH INDIVIDUAL TRUSS AND TRUSS <br />PROFILE, AND IS TO SUBMIT A FINAL SET OF TRUSS ENGINEERING SIGNED AND SEALED TRUSS <br />DRAWINGS TO DESIGN PROFESSIONAL OF RECORD FOR REVIEW PRIOR TO FABRICATION! <br />5. ANY DISCREPANCY OR ERROR IN DIMENSIONS OR NOTES WITH IN THIS PLAN SHALL BE BROUGHT <br />TO THE ATTENTION OF THE DESIGN PROFESSIONAL FOR CLARIFICATION PRIOR TO <br />CONSTRUCTION. <br />6. ALL CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION FOUND IN THESE <br />DOCUMENTS. ANY QUESTIONS REGARDING THE INFORMATION FOUND IN THESE PLANSSHOULD <br />BE DIRECTED TO OUR QUALITY ASSURANCE MANAGER AT 321-972-0491 IMMEDIATELY. NO BACK <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE THE ENGINEER WITHOUT <br />ADVANCED NOTIFICATION AND APPROVAL BY THE ENGINEER. PAYMENTS WILL BE MADE IN <br />ACCORDANCE TO THE TERMS OF THE AGREEMENT. <br />ABBOTT SQUARE <br />AMENITY CENTER <br />GENERAL STRUCTURAL NOTES <br />CAST IN PLACE REINFORCED CONCRETE <br />1 . ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI (SLABS) 3000 PSI (COLUMNS AND BEAMS), A SLUMP OF 5" <br />PLUS OR MINUS I", AND HAVE 2 TO 5% AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF ALL TOP BARS OF BEAMS. <br />3. HORIZONTAL FOOTING BARS SHALL BE BENT 25" AROUND CORNERS OR CORNER BARS WITH A 25" LAP PROVIDED EA WAY. <br />4. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR 1 1/2" TO FORM U.N.O. <br />5. FIBER MESH LENGTH SHALL BE Y2" TO 2", DOSAGE AMOUNT SHALL BE FROM 1.0 TO 1.5 LBS PER CUBIC YARD IN ACCORDANCE WITH THE <br />MANUFACTURER'S AND SHALL COMPLY WITH ASTM C1 116 <br />6. ALL REINFORCING STEEL / STIRRUPS AND TIES SHALL BE NEW DOMESTIC DEFORMED BARS FREE FROM RUST,SCALE & OIL & SHALL MEET ASTM A615/ <br />A615M GRADE 60 U.N.O. REINFORCING FOR FOOTING SHALL BE SUPPORTED ON PRE -CAST CONCRETE PADS, STEEL WIRE OR PLASTIC SUPPORT. TOP <br />REINFORCING SHALL BE POSITIVELY SUPPORTED BY TEMPORARY STRINGERS. DOWELS FOR COLUMNS & FILLED CELLS SHALL BE SECURED IN <br />PLACE BY USING ADDITIONAL CROSS- REINFORCING TIED TO FOOTING REINFORCING. SPLICES IN REINFORCING WHERE PERMITTED SHALL BE AS <br />PER DETAIL MSOSIL2. <br />7. HIGH STRENGTH SIMPSON SET EPDXY -TIE WAS USED IN THE DESIGN OF THIS PRODUCT. IF CONTRACTORS WISH TO USE A DIFFERENT EPDXY, THEY <br />MUST FIRST CONTACT THE ENGINEER OF RECORD FOR WRITTEN APPROVAL. <br />8. WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "F" OF THE FLORIDA BUILDING CODE 7TH EDITION (2020) <br />RESIDENTIAL IS TO BE IMPLEMENTED. F303.4 CONCRETE STRENGTH IN THESE AREAS ARE TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND <br />ALL NOTES ON THESE PLANS THAT INDICATE 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH. <br />MASONRY <br />1 . HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TOASTM C90-014, NTH A MINIMUM NET COMPRESSIVE <br />STRENGTH OF 2000 PSI (f m = 2000 PSI) <br />2. MORTAR SHALL BE TYPE "S", CONFORMING TO ASTM C270-14A. <br />3. COARSE GROUT SHALL CONFORM TO ASTIVI C476-10 WITH A MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH AT 28 <br />DAYS OF 3000 PSI SLUMP 8" TO 1 V. CONTINUOUS MASONRY INSPECTIONS ARE REQUIRED DURING CONSTRUCTION <br />4. GRADE 40 U.N.O. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5. GRADE 40 U.N.O.VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING OF 192 DIA OR 1OFT <br />WHICH EVER IS LESS. REINFORCING SHALL BE PLACED IN THE CENTER OF THE MASONRY CELL WITH MIN 1/2" CLEARANCE TO INSIDE FACE. <br />6. REINFORCING STEEL SHALL BE LAPPED PER DETAIL IVISOWL2, UNLESS OTHERWISE NOTED ON THE DRAWINGS. <br />7. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE <br />FLOWOF GROUT INTO CELLS BELOW. THE USE OF FELT PAPER ASA STOP IS PROHIBITED. <br />8. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR <br />9. TYPICAL FILLED CELL REINFORCING SIZE AND SPACING SHALL BE ABOVE AND BELOW ALL WALL OPENINGS <br />10. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318-14 <br />11. CONSOLIDATE POURS EXCEEDING 12" IN HEIGHT BY MECHANICAL VIBRATION, AND RECONSOLIDATE BY MECHANICAL VIBRATION AFTER INITIAL <br />WATER LOSS AND SETTLEMENT HAS OCCURRED. GROUT SHALL BE FLUSH WITH TOP OF WALL. <br />LTITSTOM <br />1. ALL EXTERIOR WOOD STUDS WALLS, BEARING WALLS, SHEAR WALLS, AND MISC. STRUCTURAL WOOD FRAMING MEMBERS,(I.E. BLOCKING OR GABLE <br />END BRACING) SHALL BE EITHER AS SPECIFIED IN PLAN OR IN DETAILS. IF CONFLICTS OCCUR BETWEEN PLAN AND DETAILS, THE STRONGEST <br />MATERIAL SHALL BE USED. AT A MINIMUM, ALL WOOD STRUCTURAL FRAMING MEMBERS SHALL BE SPF #2. <br />2. ALL LUMBER SPECIFIED ON DRAWINGS ARE INTENDED FOR DRY USE ONLY (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND <br />FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHERS <br />3. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION <br />SHIELDS. ALL HOLES OVER 1" IN DIA. FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD SHOES,TYP., U.N.O. <br />4. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO <br />VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, <br />CBA-A OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. <br />5 ' ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH OR CONCRETE TO BE PRESSURE TREATED. <br />6. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS <br />WITHOUT WOODEN TOP PLATES. <br />7. SEE PLAN FOR STUD PACK AND BEAM NAILING PATTERNS <br />8. ALL ENGINEERED LUMBER TO HAVE THE FOLLOWING MIN VALUES U.N.O. <br />PARALLAM COLUMNS: 1.8E Fb = 2400 PSI <br />MICROLAM (LVL) BEAMS: 2.OE Fb= 2600 PSI <br />GLULAM BEAMS: SP/SP 24F-V5 LAYUP (1.7E FB=2400 PSI) MIN. <br />9. SEE PLAN NOTE FOR ADDITIONAL ROOF, WALL, SHEAR WALL AND FLOOR SHEATHING REQUIREMENTS ALONG W/ NAILING INFORMATION OTHERWISE: <br />9.1. ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />9.2. FLOOR SHEATHING: T&G A-C GROUP 1 APA RATED (48/24) SHEATHING SHALL FINISH FLUSH TO EXTERIOR WALL FACE. <br />9.3. WALL SHEATHING: 7/16"STRUCTURAL I OSB EXPOSURE 1 OR 1/32" RATED OSB EXPOSURE 1 (SPECIFIC GRAVITY, G=0.50, MIN.). A MINIMUM Ys" SPACE <br />IS RECOMMENDED BETWEEN PANELS AT EDGE AND END JOINTS TO ALLOW FOR EXPANSION. PER R604.3 SHEATHING SHALL NOT BE USED AS <br />WEATHER RESISTANCE BARRIER UNLESS SPECIFIED. <br />10. LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED TO <br />WOOD SHEATHING WITH 1Y2" LONG, 11 GAGE NAILS HAVING A 7/16" HEAD, OR 1 Y2" LONG, 16 GAGE STAPLES, SPACED IN ACCORDANCE WITH ASTM C1062 <br />OR C1787, OR AS OTHERWISE APPROVED (REF. 2020 FBC-R-R703.7.1). <br />STRUCTURALSTEEL <br />1 . MATERIAL SPECIFICATIONS: WIDE FLANGE SECTIONS: ASTM A992, GRADE 50, Fy=50 KSI TUBE STEEL (HSS): ASTM A500, GRADE B, Fy = 46 KSI PIPE <br />STEEL: ASTM F3125, TYPE E OR S, Fy = 35 KSI ALL OTHER STRUCTURAL & MISC. STEEL: A36 Fy=36 KSI STRUCTURAL CONNECTIONS: ALL STRUCTURAL <br />BOLTS TO BE A325 U.N.0 <br />2. STRUCTURAL BOLTS SMALLER THAN 5/8" DIA. TO BE A307 THREADED ROD SHALL CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CONFORM TO <br />ASTM F1 554 ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINFORCEMENT SHOP <br />DRAWINGS TO BE PROVIDED TO ENGINEER OF RECORD BEFORE FABRICATION FOR REVIEW AND APPROVAL <br />3. STRUCTURAL CONNECTIONS: ALL STRUCTURAL BOLTS TO BE A325N U.N.O. ALL A325N BOLTS SHALL BE BROUGHT TO A "SNUG-TIGHT"CONDITION , AS <br />DEFINED IN THE SPECIFICATION. SLIP CRITICAL (SC) BOLTS MUST BE FULLY TENSIONED PER SPECIFICATION STRUCTURAL BOLTS SMALLER THAN 5/8" <br />DIA. TO BE A307 THREADED ROD SHALL CONFORM TO A36 OR A307 ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 ALL BOLTS CAST IN CONCRETE: <br />ASTM A36 OR ASTM A-307 SHOP AND FIELD WELDS: E70XX ELECTRODES STEEL REINFORCEMENT SHOP DRAWINGS TO BE PROVIDED TO ENGINEER <br />OF RECORD BEFORE FABRICATION FOR REVIEW AND APPROVAL. WELDED CONNECTIONS: ELECTRODES - E70XX UNO (LOW HYDROGEN). FILLET <br />WELDS SHALL BE 3/16" UNO. <br />4. SUBMIT SHOP DRAWINGS INDICATING ALL SHOP AND ERECTION DETAILS INCLUDING PROFILES, SIZES, SPACING, AND LOCATIONS OF STRUCTURAL <br />MEMBERS, CONNECTION ATTACHMENTS, FASTENERS, LOAD, AND TOLERANCES. <br />5. STRUCTURAL STEEL SHALL RECEIVE SHOP COAT OF PRIMER (COLOR AS DIRECTED BY ARCHITECT) EXCEPT FOR AREAS WHICH WILL RECEIVE <br />SPRAY -ON FIRE PROTECTION.. <br />6. A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH PLANS AND <br />SPECIFICATIONS (IF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. <br />PRE ENGINEERED WOOD TRUSSES <br />1 . ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR <br />ANCHORS PER STRUCTURAL PLAN <br />2. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL DESIGN SPECIFICATION FOR <br />STRESS -GRADE LUMBER AND ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPORTIONED (WITH A MAXIMUM ALLOWABLE STRESS INCREASE FOR LOAD DURATION OF 25%) TO <br />WITHSTAND THE LIVE LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY THE TRUSS MANUFACTURER UNLESS NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE <br />DESIGNED BY THE TRUSS MANUFACTURER IN ACCORDANCE WITH THE FRAMING DESIGN LOADS; <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL PLATE CONNECTED WOOD TRUSSES PER THE TRUSS PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS AND GOVERNING CODES. <br />SUBMITTALS SHALL INCLUDE TRUSS FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, BRACING, ANCHORAGE, CONNECTIONS, TRUSS <br />LOCATIONS, AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH SUBMITTAL <br />SHALL BE SIGNED AND SEALED BY A FLORIDA REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR REVIEW AND APPROVAL PRIOR TO <br />FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS <br />SHALL SHOWALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br />UPLIFT CONNECTORS <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE <br />EXPOSED TO UPLIFT OR LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. THE MEMBERS OF <br />THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE COORDINATE THE TRUSS ENGINEER FOR THE LOCATION OF THESE <br />WALLS.AND STRUCTURAL PLANS FOR MORE INFO. <br />FIELD REPAIR NOTES <br />1 . MISSED "J" BOLTS FOR WOOD BEARING WALLS MAY BE SUBSTITUTED WITH 1/2" DIA. EPDXY ANCHORS WITH 7" EMBEDMENT. SIMPSON "SET" EPDXY <br />ADHESIVE BINDER FOLLOWING ALL MANUFACTURER'S RECOMMENDATIONS OR SIMPSON 1/2" TITEN HD BOLTS WITH MINIMUM 7" EMBEDMENT, SEE <br />PLAN FOR EMBEDMENT DEPTH AT FLOOR STEPS. <br />2. FOR MISSED VERT. DOWELS, DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF THE OMITTED REBAR AND INSTALL A 32" LONG #5 BAR INTO <br />THE EPDXY FILLED HOLE. USE A TWO PART EMBEDMENT EPDXY (SIMPSON HIGH STRENGTH EPDXY -TIE ANCHORING ADHESIVE) MIXED PER THE <br />MANUFACTURER'S INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND USING <br />COMPRESSED AIR PRIOR TO APPLYING THE EPDXY. ALLOW THE EPDXY TO CURE TO THE MANUFACTURER'S SPECIFICATIONS, THEN FILL THE CELL IN <br />THE NORMAL WAY DURING BOND BEAM POUR. <br />3. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT. IN CONC. FILLED CELL EACH SIDE OF THE JOINT (BAR DOES NOT HAVE TO BE CONT. TO <br />FOOTING). <br />4. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY BE SUBSTITUTED WITH (1) SIMPSON MTSM16 TWIST STRAP W/ (4) Y4"x 21/4" TITENS TO <br />MASONRY AND (7)-10d NAILS TO TRUSS FOR UPLIFTS LESS THAN 860 LBS (USE (2) MTSM16 FOR UPLIFTS LESS THAN 1660#). IF CORNER STRAP IS <br />MISSED, CONTRACTOR IS TO INSTALL (2) SIMPSON HGAM1 0 W1 (4) 1/4" X 1 1/2" SDS SCREWS AND (5) 1/4" x 2 1/4" TITENS ONE EACH SIDE OF TRUSS. <br />5. NO MORE THAN 10 STRAPS MAYBE SUBSTITUTED OR NO MORE THAN 3 INA ROW WITHOUT APPROVAL FROM EOR. IF GIRDER TRUSS CONNECTIONS <br />ARE MISSED, CONTACT THE EOR FOR SUBSTITUTION. <br />6. IF MISSED, MSTAM36 OR MSTAM40 STRAP IS MISSED FOR 2ND FLOOR JAMB STUD CONNECTION, CONTRACTOR MAY INSTALL SIMPSON HTT5 W1(26) <br />16d x 21/2" NAILS AND 5/8" ANCHOR BOLT SET IN SIMPSON HIGH STRENGTH EPDXY W/ MIN 6" EMBEDMENT AND MIN 3" EDGE DISTANCE. CONTACT EOR <br />IF STRAPS ARE MISSED UNDER GIRDER JAMB STUD LOCATIONS. <br />STRUCTURAL DESIGN CRITERIA <br />• FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL. <br />• FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020) <br />• FLORIDA BUILDING CODE ACCESSIBILITY 7TH EDITION (2020) <br />• NFPA 70-17. NATIONAL ELECTRICAL CODES. (NEC 2017) <br />• BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE - (ACI 318-14). <br />• SPECIFICATIONS FOR STRUCTURAL CONCRETE - (ACI 301-16). <br />• BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES - (ACI 530-13). <br />• NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION - 2018 EDITION. <br />• WOOD FRAMED CONSTRUCTION MANUAL 2018 EDITION. <br />• APA PLYWOOD DESIGN SPECIFICATION E30-16 <br />• AMERICAN SOCIETY OF CIVIL ENGINEERS: ASCE / SEI 7-16 <br />• ALUMINUM DESIGN MANUAL - AFF-20 <br />GENERAL ROOF LOADING <br />SHINGLE <br />METAL <br />TILE <br />HEAVY <br />ROOF (PSF) <br />ROOF (PSF) <br />ROOF (PSF) <br />ROOF (PSF) <br />TOP CHORD LL <br />20 <br />20 <br />20 <br />20 <br />TOP CHORD DL <br />10 <br />10 <br />15 <br />25 <br />BOTTOM CHORD LL* <br />0 <br />0 <br />0 <br />0 <br />BOTTOM CHORD DL <br />10 <br />10 <br />10 <br />10 <br />TOTAL(PSF) <br />40 <br />40 <br />45 <br />55 <br />BOTTOM CHORD LL (OPT) <br />ATTICS W/ LIMITED STORAGE <br />20 <br />ATTICS W/ HEAVY STORAGE <br />50 <br />* ATTICS W/ NO STORAGE <br />10 <br />(NUN- UN. URRENT) <br />I <br />I <br />I <br />NOTE: LL REDUCTIONS ARE ALLOWED PER CODE BUT ONLY WITH WRITTEN <br />APPROVAL FROM EOR OR INDICATED ON PLAN <br />GENERAL FLOOR LOADING <br />TOP CHORD ILL <br />40 (PSF) <br />COMMENTS: <br />TOP CHORD DL <br />10 (PSF) <br />BOTTOM CHORD LL <br />0 (PSF) <br />BOTTOM CHORD DL <br />5 (PSF) <br />SPECIAL FLOOR LOADING <br />GAME ROOM / READING ROOMS <br />60 (PSF) <br />COMMENTS: <br />BALCONIES/ DECKS <br />40(PSF) <br />d. A SINGLE CONCENTRATED LOAD <br />BALCONIES OVER 100 SQ:FT <br />100(PSF) <br />APPLIED IN ANY DIRECTION AT ANY <br />LIGHT STORAGE <br />125(PSF) <br />POINT ALONG THE TOP. <br />GUARDRAILS AND HANDRAILS <br />200(LBS)(d) <br />f. BALUSTERS AND PANELS FILLERS <br />GUARDRAIL IN -FILL COMPONENTS <br />50 (LBS)(f)I <br />SHALL BE DESIGNED TO WITHSTAND <br />STAIRS / NON SLEEPING ROOMS <br />40 (PSF) <br />A HORIZONTALLY APPLIED NORMAL <br />SLEEPING ROOMS <br />30 (PSF) <br />LOAD OF 50 POUNDS ON AN AREA <br />LIBRARIES - STACK ROOMS <br />150(PSF) <br />EQUAL TO 1 SQ. FT. <br />HABITABLE ATTICS SERVED <br />w/ FIXED STAIRS <br />30(PSF) <br />PASSENGER VEHICLE GARAGES <br />50(PSF) <br />DEFLECTION <br />CRITERIA <br />ROOF TRUSSES* <br />LU360 <br />TU240 <br />COMMENTS: <br />ROOF RAFTERS <br />LU180 <br />TU120 <br />ROOF RAFTERS (W/O CLGJ <br />LU360 <br />TU240 <br />FLOOR TRUSSES/ BEAMS <br />LU360 <br />TU240 <br />FLOOR I-JCIST*** <br />LU480 <br />TU240 <br />*TL MAX 2" UP TO 40FT SPAN ****TL MAX 1/4" DIFFERENTIAL BETWEEN <br />**TL MAX 3/4" ADJACENT TRUSSES <br />*** TL MAX 1/2" <br />WIND LOADING CRITERIA <br />WIND SPEED (ULTIMATE) <br />P I <br />FwB <br />150.0 MPH <br />W W I S P <br />IND SPEED (ALLOWABLE) <br />116.0 MPH <br />EXPOSURE CATEGORY <br />P �S <br />C <br />al 1 11 <br />UILDING CATEGORY <br />11 <br />BUILDING TYPE <br />V <br />ENCLOSURE CLASSIFICATION <br />ENCLOSED <br />INTERNAL PRESSURE COEFFICIENT <br />+/-0.18 <br />NOTE: MEAN ROOF HEIGHT FOR TYPICAL SINGLE STORY HOME IS 15FT, AND FOR <br />2 STORY HOME IS 30FT <br />ASCE 7-16 WALL DESIGN ALLOWABLE COMPONENTS <br />AND CLADDING WIND PRESSURES AND SUCTIONS <br />FOR MEAN ROOF HEIGHT:5 60 ft <br />EFFECTIVE <br />WIND PRESSURE AND SUCTION (PSF <br />WIND AREA <br />(+) VALUE DENOTES PRESSURE <br />WIND PRESSURE AND <br />(SQ FEET) <br />VALUE DENOTES SUCTION <br />1 <br />SUCTION DIAGRAM <br />AREA <br />(A) <br />(1 <br />10-19.99 <br />r+) 34 0 <br />(:A) - <br />(+)34.0 <br />(D) <br />(-)36.4 <br />(-)44.8 <br />20-49 .99 <br />(+)32.5 <br />(+)32.5 <br />(-)35.0 <br />(-)42.0 <br />50 - 99.99 <br />(E) (+)30.4 <br />(E) (+)30.4 <br />(-)32.2 <br />(-)37.8 <br />> 100 <br />(+)28.8 <br />(+)28.8 <br />(-)30.8 <br />(-)35.0 <br />DIAGRAM <br />GARAGE DOORS* <br />SOFFIT <br />9'-0" x 7'-0" <br />16'-0" x 7'-0" <br />(+)34.0 <br />(+)29.8 <br />Q) <br />(+)28.6 <br />(K) <br />(-)33.7 <br />(-)31.8 <br />(-)44.8 <br />GENERAL PRESSURE NOTES <br />11. <br />NOTES: <br />MULTIPLY THE ABOVE PRESSURES BY 1.67 TO GET ULTIMATE WIND <br />PRESSURES. <br />2. "a" = END ZONE IS ONLY WITHIN 4'-0" OF ALL EXTERIOR BUILDING CORNERS. <br />INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, <br />OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREAS. <br />3. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR <br />GREATER AND IS CONSIDER TO BE IN THE WIND -BOURNE DEBRIS AREA. <br />CONTRACTOR TO PROVIDED ADDITIONAL INFO AS REQUIRED FOR <br />PERMITTING. <br />SHEETINDEX <br />so <br />NOTES & SCHEDULES <br />S1 <br />FOUNDATION PLAN <br />S2 <br />LOW ROOF PLAN <br />S3 <br />HIGH ROOF FRAMING PLAN <br />Ll <br />LINTEL PLAN <br />L2 <br />LINTEL CHART & NOTES <br />SN <br />NOTES & SCHEDULES <br />D1 <br />FOUNDATION DETAILS <br />D2 <br />FRAMING DETAILS <br />D3 <br />FRAMING DETAILS <br />0 V <br />Z co <br />Co <br />Z <br />V) 0 <br />4-1 LU <br />0 <br />U C14 <br />0 LU <br />V) <br />Ln L0 <br />a) C14 <br />a ce) <br />LU M cl) <br />-0 Cl) <br />E .. c) <br />8 CC,34 <br />4i co <br />c) <br />MCD <br />< 0 <br />24 '20 61 <br />N-C B D C <br />THIS DOCUMENT AND/OR THE DESIGN <br />CONCEPTS EXPRESSED HEREIN ARE THE <br />PROPERTY OF KEESEE ASSOCIATES AND <br />ALL RIGHTS OF OWNERSHIP, INCLUDING <br />COPYRIGHT OF INTELLECTUAL PROPERTY, <br />ARE RESERVED THE REPRODUCTIONS, <br />COPYING, OR USE OF THIS DOCUMENT <br />AND/OR THE DESIGN CONCEPT WITHOUT <br />THE WRITTEN CONSENT OF KEESEE <br />ASSOCIATES IS STRICTLY PROHIBITED AND <br />PROTECTED BY UNITED STATES AND <br />INTERNATIONAL LAW. <br />0 1 , <br />E N <br />Ui <br />NO 750 <br />W <br />ix� :XZ <br />W Z <br />STATtE CIF <br />47 / <br />W <br />02 <br />N A\- <br />UJ <br />0 <br />00 <br />'0 <br />E <br />M <br />Z <br />2 <br />a. <br />Z <br />W <br />0 <br />FU <br />TF <br />SHEET INFORMATION <br />DATE: 10/15/2021 <br />DRAWN BY: NJ <br />PROJECT NO: 21-6096 <br />REVIEWED BY: SL <br />Plan Revisions Date: <br />DOOR AT BACK LANAI <br />NOTES & <br />SCHEDULES <br />No. so <br />