Laserfiche WebLink
RAISED BORDER <br />5/8" MIN - ZMAX HIGH RAISED <br />CHARACTERS <br />EXIT <br />.. Z` <br />GRADE 2 BRAILLE (TYP.) <br />SIGNS SHALL BE DESIGNED AND <br />INSTALLED IN ACCORDANCE WITH NFPA <br />101, SECT 7.10.1.3 AND ICC/ANSI A117.1, <br />SECT 703.3 -703.4 <br />NOTE: <br />1. ALL COPY AND GRAPHICS SHALL BE RAISED 1/32" <br />2. LETTERFORM SHALL BE SANS SERIF <br />EXIT DOOR IDENTIFICATION DETAIL <br />SCALE: NTS <br />NOTE. <br />GC TO COORD, TYPE AND LOCATION OF ALL FIRE <br />EXTINGUISHERS WITH LOCAL FIRE CHIEF PRIOR TO <br />INSTALLATION <br />PROVIDE WALL BLOCKING SUPPORT <br />WHERE REQUIRED <br />WALL MOUNTED EXTINGUISHER AMEREX <br />MODEL # 2160 WITH MOUNTING BRACKET <br />LOCATED IN KITCHEN, IN PUBLIC AREAS <br />PROVIDE AS INDICATED ON PLANS LB-4A60BC <br />FIRE EXTINGUISHERS WITH MOUNTING <br />BRACKET (COORDINATE LOCATIONS WITH FIRE <br />MARSHAL) <br />FINISH FLOOR <br />FIRE EXTINGUISHER DETAIL <br />SCALE: NTS <br />ROOM OCCUPANCY SCHEDULE <br />ROOM <br />NUMBER <br />ROOM NAME <br />OCCUPANCY <br />CLASSIFICATION <br />GROSS <br />ROOM AREA <br />OCCUPANT <br />LOAD FACTOR <br />OCCUPANCY <br />LOAD CALCULATED <br />OCCUPANCY <br />LOAD PROVIDED <br />REQUIRED <br />EGRESS WIDTH <br />FIRST FLOOR PLAN <br />100 <br />ENTRY <br />CIRCULATION <br />372 SF <br />--- <br />--- <br />--- <br />--- <br />101 <br />WRAP -AROUND PORCH <br />CIRCULATION <br />809 SF <br />--- <br />--- <br />--- <br />--- <br />102 <br />LANAI <br />CIRCULATION <br />700 SF <br />--- <br />--- <br />--- <br />--- <br />102A <br />CLOSET <br />NO OCCUPANCY <br />28 SF <br />--- <br />--- <br />--- <br />--- <br />103 <br />FOYER <br />CIRCULATION <br />380 SF <br />--- <br />--- <br />--- <br />--- <br />104 <br />GREAT ROONI <br />ASSEMBLY <br />1,073 SF <br />15 SF <br />72 PPL <br />72 PPL <br />15" <br />105 <br />MECH. / ELEC. <br />STORAGE <br />67 SF <br />300 SF <br />1 PPL <br />1 PPL <br />.2" <br />106 <br />SNACK AREA <br />WARMING KITCHEN <br />163 SF <br />100 SF <br />2 PPL <br />2 PPL <br />.4" <br />107 <br />STORAGE <br />STORAGE <br />73 SF <br />100 SF <br />1 PPL <br />1 PPL <br />.2" <br />108 <br />HALLWAY <br />CIRCULATION <br />89 SF <br />--- <br />--- <br />--- <br />--- <br />108A <br />JANITOR CL. <br />NO OCCUPANCY <br />15 SF <br />--- <br />--- <br />--- <br />--- <br />108B <br />HALLWAY <br />CIRCULATION <br />93 SF <br />--- <br />--- <br />--- <br />--- <br />109 <br />RECEPTION <br />BUSINESS <br />50 SF <br />100 SF <br />1 PPL <br />1 PPL <br />.2" <br />109A <br />CLOSET <br />NO OCCUPANCY <br />15 SF <br />--- <br />--- <br />--- <br />110 <br />OFFICE <br />BUSINESS <br />109 SF <br />100 SF <br />1 PPL <br />1 PPL <br />.2" <br />111 <br />FITNESS ROOM <br />EXERCISE W/ EQUIP. <br />596 SF <br />50 SF <br />12 PPL <br />12 PPL <br />2.4" <br />111A <br />MECH. / ELEC. <br />NO OCCUPANCY <br />35 SF <br />--- <br />--- <br />--- <br />--- <br />112 <br />MEN'S RR <br />NO OCCUPANCY <br />402 SF <br />--- <br />--- <br />--- <br />--- <br />112A <br />VESTIBULE <br />CIRCULATION <br />29 SF <br />--- <br />--- <br />--- <br />112B <br />VESTIBULE <br />CIRCULATION <br />33 SF <br />--- <br />--- <br />--- <br />--- <br />113 <br />WOMEN'S RR <br />NO OCCUPANCY <br />400 SF <br />--- <br />--- <br />--- <br />--- <br />113A <br />VESTIBULE <br />CIRCULATION <br />25 SF <br />--- <br />--- <br />--- <br />--- <br />113B <br />VESTIBULE <br />CIRCULATION <br />33 SF <br />--- <br />--- <br />--- <br />--- <br />TOTALS: <br />90 PEOPLE <br />90 PEOPLE <br />18" <br />TOTAL EGRESS PROVIDED: <br />72" <br />NOTES: <br />NOTES: <br />1. SCHEDULE COMPLIES WITH FBC 2020 7TH EDITION TABLE 1004.1.2 <br />2. REQUIRED EGRESS WIDTH IN INCHES FOR STAIRWAYS PROVIDES .3" PER OCCUPANT AS PER FBC 2020 7TH EDITION 1005.3.1 <br />3. REQUIRED EGRESS WIDTH IN INCHES FOR OTHER EGRESS COMPONENTS PROVIDES .2" PER OCCUPANT AS PER FBC 2020 7TH EDITION 1005.3.2 <br />4. ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN AREA HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE PERMITTED TO BE PROVIDED WITH A LATCH OR LOCK ONLY IF THE LATCH <br />OR LOCK IS PANIC HARDWARE OR FIRE EXIT HARDWARE AS PER NFPA 101:12.2.2.2. <br />PLUMBING FIXTURE REQUIREMENTS <br />DRINKING <br />MOP <br />REQUIRED FIXTURES <br />WATER CLOSETS <br />LAVATORIES <br />SHOWERS <br />URINAL <br />MEN WOMEN <br />FOUNTAINS <br />SINK <br />OCCUPANTS CALCULATION BASIS: 90 OCCUPANTS <br />MEN <br />WOMEN <br />MEN <br />WOMEN <br />(45 MEN, 45 WOMEN ASSUMED DESIGN BASIS) <br />FIXTURE RATIO REQUIRED <br />1 PER 40 <br />1 PER 40 <br />1 PER 75 <br />1 PER 75 <br />0 <br />0 <br />1 PER 500 <br />1 REQUIRED <br />FIXTURES REQUIRED <br />1 <br />1 <br />1 <br />1 <br />0 <br />0 <br />1 <br />1 <br />FIXTURES PROVIDED <br />4 <br />6 <br />3 <br />3 <br />1 <br />1 <br />1 <br />1 <br />POOL SF = 5,833 SF <br />2 <br />6 <br />2 <br />2 <br />2 <br />POOL FIXTURES REQUIRED <br />POOL FIXTURES PROVIDED <br />4 <br />6 <br />4 <br />4 <br />2 <br />NOTES: <br />z0 <br />O <br />z N o0 <br />z* <br />Q EZ <br />u, z1c: <br />Lr) U <br />Q <br />i--d W <br />M Q <br />0 <br />o <br />V <br />N <br />O L-U <br />a) <br />� c <br />� <br />V) <br />� <br />� <br />U <br />�M <br />W <br />M <br />J -0 <br />M <br />00 <br />- N <br />M 0 <br />aj <br />® <br />O <br />L_ co <br />N <br />cc) <br />O C <br />C ° <br />aa) <br />y <br />o <br />00 .Fu <br />Q m <br />N :E O <br />o.l ICI fi <br />THIS DOCUMENT AND/OR THE DESIGN <br />CONCEPTS EXPRESSED HEREIN ARE THE <br />PROPERTY OF KEESEE ASSOCIATES AND <br />ALL RIGHTS OF OWNERSHIP, INCLUDING <br />COPYRIGHT OF INTELLECTUAL PROPERTY, <br />ARE RESERVED THE REPRODUCTIONS, <br />COPYING, OR USE OF THIS DOCUMENT <br />AND/OR THE DESIGN CONCEPT WITHOUT <br />THE WRITTEN CONSENT OF KEESEE <br />ASSOCIATES IS STRICTLY PROHIBITED AND <br />PROTECTED BY UNITED STATES AND <br />INTERNATIONAL LAW. <br />a <br />w GO <br />co <br />34 3 , <br />z�' ?w <br />Vat Q J <br />wO� <br />�w <br />Q� <br />Z <br />a <br />LLI <br />cl) <br />U <br />H <br />� <br />H <br />— <br />O <br />Z <br />m <br />w <br />m <br />g <br />QQ <br />SHEET INFORMATION <br />DATE: 08 / 30 / 2021 <br />DRAWN BY: DRS/MAB <br />PROJECT NO: 20-6001 <br />REVIEWED BY: ST <br />IVI Plan Revisions Date: <br />1 RFI #1 6.22.21 <br />2 OWNER COMMENTS 8.30.21 <br />Sheet Name <br />LIFE SAFETY <br />SCHEDULES <br />Sheet No <br />Al 00 <br />