- , __ 11 � I, _ __ I I I I H I 1 11 � F-11 III � N1 `qvp 11 1 1 1 1 11111 111 11 1 1 , I I I L_ - I I I - I I I - __ _L 1 1 -1 1111 111 1 L_� I ___ ll I � I'l 1 111 1 i I I I ' 1 I'll __ <br />R A A Of-%K I MX/ <br />1. MASONRY CONSTRUCTION MATERIALS AND INSPECTIONS SHALL CONFORM TO THE LATEST <br />EDITION OF ACI BUILDING CODE REQUIREMENTS FOR CONCRETE MASONRY STRUCTURES <br />(ACI 530/ASCE5/TMS 402), LATEST EDITION, SPECIFICATIONS FOR MASONRY STRUCTURES <br />(ACI 530.1/ASCE6/TMS 602), LATEST EDITION, ASTM C476, ASTM C1019, AND NCMA TEK 107. <br />2. CONCRETE BLOCKS SHALL CONFORM TO ASTM C90 (ftn = 2,000 PSI). <br />3. MORTAR SHALL COMPLY WITH ASTM C270, TYPE S FOR ALL MASONRY WALLS. <br />4. BLOCK SHALL NOT BE MOISTENED BEFORE GROUTING. <br />5� ALL MASONRY CROSS WEBS SHALL BE FULLY BEDDED IN MORTAR AROUND CELLS TO BE <br />GROUTED. <br />6. REINFORCE WALLS VATH LADDER TYPE HORIZONTAL JOINT REINFORCEMENT COMPLYING <br />WITH ASTM A951. SIDE RODS AND CROSS RODS OF HORIZONTAL JOINT REINFOREMENT <br />SHALL BE A MINIMUM OF 9 GAUGE AND HORIZONTAL JOINT REINFORCIVIENT SHALL BE <br />INSTALLED IN MASONRY BED JOINTS AT A MAXIMUM OF 16-INCHES ON CENTER MEASURED <br />VERTICALLY. INSTALL HORIZONTAL JOINT REINFORCMENT PER MANUFACTURER'S <br />RECOMMENDATIONS AND LAP ALL JOINTS A MINIMUM OF 8-INCHES. <br />7. VERTICAL REINFORCING MUST HAVE A MINIMUM CLEARANCE OF Y4-INCH TO THE INSIDE <br />FACE SHELL OF MASONRY BLOCK. VERTICAL REINFORCEMENT IN WALLS SHALL BE <br />SECURED AND LATERALLY SUPPORTED AGAINST DISPLACEMENT AT INTERVALS NOT <br />EXCEEDING 192 BAR DIAMETERS OR 10-FT., WHICHEVER IS LESS, WHENEVER A CLEANOUT <br />IS REQUIRED. SEE GROUTING DETAIL NOTE FOR CLEANOUT REQUIREMENTS. <br />8. GROUT PLACEMENT STOPPED FOR (1) HOUR OR MORE SHALL BE STOPPED 1 Y2-INCHES <br />BELOW TOP OF MASONRY BLOCK TO PROVIDE A KEY FOR SUBSEQUENT GROUTING. <br />9. ALL GROUTING POURS SHALL BE CONSOLIDATED AND RECONSOLIDATED AFTER INITIAL <br />WATER LOSS AND SETTLEMENT HAS OCCURRED BYMECHANICAL VIBRATION PER ACI <br />530.1/TMS 602/ASCE 6. CONSOLIDATION OR RECONSOLIDATION IS NOT REQUIRED FOR <br />SELF -CONSOLIDATING GROUT. <br />10. TYPICAL VERTICAL REINFORCING SIZE AND SPACING SHALL CONTINUED ABOVE AND BELOW <br />ALL WALL OPENINGS. <br />11. TEMPORARY BRACING AND SHORING OF WALLS TO PROVIDE STABILITY DURING <br />CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />12. PROVIDE PRE -CAST LINTEL SUBMITTALS SIGNED AND SEALED BY A SPECIALTY ENGINEER <br />WHO IS LICENSED IN THE SAME STATE AS THE PROJECT LOCATION. <br />13. STOPPING AND RESUMING WORK: RACK BACK 1/2-MASONRY UNIT LENGTH IN EACH <br />COURSE. DO NOT TOOTH. CLEAN EXPOSED SURFACES OF SET MASONRY. REMOVE LOOSE <br />MASONRY UNITS AND MORTAR PRIOR TO LAYING FRESH MASONRY. <br />14. REINFORCE MASONRY OPENINGS GREATER THAN V-10" WIDE WITH HORIZONTAL JOINT <br />REINFORCEMENT PLACED IN (2) HORIZONTAL JOINTS APPROXIMATELY 8-INCHES APART, <br />IMMEDIATELY ABOVE THE LINTEL AND IMMEDIATELY BELOW THE SILL. EXTEND <br />REINFORCING A MINIMUM OF Z-O" BEYOND THE JAMBS OF THE OPENING EXCEPT AT <br />CONTROL JOINTS. SEE PLAN FOR ADDITIONAL REQUIREMENTS. <br />15. DO NOT APPLY UNIFORM LOADS TO NEWLY CONSTRUCTED MASONRY WALLS FOR (3) DAYS. <br />16. DO NOT APPLY CONCENTRATED LOADS TO NEWLY CONSTRUCTED MASONRY WALLS FOR (7) <br />DAYS. <br />17. EXTEND ALL VERTICAL WALL REINFORCEMENT TO VVITHIN 2" OF TOP OF WALL OR BEAM <br />UNLESS NOTED OTHERWISE. TERMINATE REINFORCING WITH STANDARD ACI 90-DEGREE <br />HOOK. <br />18. SEE ARCHITECTURAL AND STRUCTURAL CONSTRUCTION DOCUMENTS FOR MASONRY <br />CONTROL JOINT (MCJ) LOCATIONS. MASONRY CONTROL JOINT SPACING SHALL NOT <br />EXCEED 3x THE MASONRY WALL HEIGHT (IN FEET) OR 25-FEET, Vv1-­IICHEVER IS LESS <br />(UNLESS NOTED OTHERWISE). <br />19. REFER TO ARCHITECTURAL CONSTRUCTION DOCUMENTS FOR WATERPROOFING DETAILS <br />AT MASONRY CONTROL JOINTS. <br />20. ALL MASONRY REINFORCING SHALL CONFORM TO ASTM A615 (GRADE 60), UNLESS NOTED <br />OTHERWISE. <br />21. SEE THE'REBAR BEND & SPLICE DETAIL'IN THESE DRAWINGS FOR STANDARD LAP SPLICE <br />LENGTHS AND BENDING REQUIREMENTS FOR REINFORCING BARS. <br />22. JOB SITE MIXING OF GROUT SHALL NOT BE PERMITTED. TESTING SHALL CONFORM TO ASTM <br />C1019. SEE TEST MOLD DETAIL BELOW. SEE SCHEDULE UNDER CONCRETE NOTES FOR <br />COMPRESSIVE STRENGTH AND SLUMP REQUIREMENTS. <br />GROUT TEST PRISM <br />COVER UNITS USING -4r <br />ABSORPTIVE PAPER <br />TOWELLING W/ TAPE (4) 8x8x16 CMU BLOCKS <br />I REQUIRED (FRONT BLOCK <br />3"x3"x1 5/8" WOOD BLOCK REMOVED FOR CLARITY) <br />DETAIL - MASONRY GROUT <br />TEST MOLD (ASTM C1019) <br />WOOD <br />1. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR WALLS AND MISC. STRUCTURAL <br />WOOD FRAMING MEMBERS, (I.E. BLOCKING OR GABLE END BRACING) SHALL BE #2 <br />SOUTHERN YELLOW PINE OR AS NOTED ON PLANS. <br />2. ALL LUMBER SPECIFIED ON DRAWINGS ARE INTENDED FOR DRY USE ONLY (MOISTURE <br />CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY <br />OTHERS <br />3. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE CENTER OF <br />THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION SHIELDS. ALLHOLESOVER111IN <br />DIA. FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD <br />SHOES,TYP., U.N.O. <br />4. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO <br />STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD <br />TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR <br />EXAMPLE, ACQ-C, ACQ-D, CBA-A OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS <br />STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. <br />5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH OR CONCRETE TO BE PRESSURE <br />TREATED. <br />6. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY. <br />SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. <br />7. SEE PLAN FOR STUD PACK AND BEAM NAILING PATTERNS <br />8. ALL ENGINEERED LUMBER TO HAVE THE FOLLOWING MIN VALUES U.N.O. <br />COLUMNS: 2.OE Fb = 2600 <br />BEAM: 2.OE Fb= 2600 <br />9. SEE PLAN NOTE FOR ADDITIONAL ROOF, WALL, SHEAR WALL AND FLOOR SHEATHING <br />REQUIREMENTS ALONG W/ NAILING INFORMATION OTHERWISE: <br />9.1. ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />9.2. FLOOR SHEATHING: T&G A-C GROUP 1 APA RATED (48/24) SHEATHING SHALL <br />FINISH FLUSH TO EXTERIOR WALL FACE. <br />9.3. WALL SHEATHING: PLYWOOD C-C/C-D EXTERIOR OR OSB-15/32" EXPOSURE 1. A <br />MINIMUM J" SPACE IS RECOMMENDED BETWEEN PANELS AT EDGE AND END <br />JOINTS TO ALLOW FOR EXPANSION. <br />UPLIFT CONNECTORS <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS <br />ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL <br />FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. <br />THE MEMBERS OF THESE WALLS WOULD NOT NEED TO HAVE CONNECTORS APPLIED. <br />PLEASE COORDINATE THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS.AND <br />STRUCTURAL PLANS FOR MORE INFO. <br />WOOD TRUSSES <br />1 ALL TRUSS CONNECTOR PLATES SHALL BE MANUFACTURED FROM ASTM A466-72 GRADE A <br />GALVANIZED STEEL OF NO LESS THAN 20 GAGE THICKNESS WITH 4 MINIMUM YIELD OF 33,000 <br />PSI AND AN ULTIMATE TENSILE STRENGTH OF 45,000 PSI. CONNECTOR PLATE GAUGES <br />SHALL BE AS REQUIRED BY MANUFACTURERS DESIGN CALCULATIONS. <br />2. TRUSS SHOP DRAWINGS SHALL BE SUBMITTED FOR THE ARCHITECTS REVIEW PRIOR TO <br />FABRICATION AND SHALL INCLUDE THE FOLLOWINGS: <br />2.1. STRESS REDUCTION FACTORS FOR PLATES <br />2.2. TOP AND BOTTOM CHORD DESIGN LOADS IN P.L.F. <br />2.3. SIZE, GAUGE, AND EXACT LOCATION BY DIMENSION OF PLATES <br />2.4. LUMBER SPECIES AND GRADES USED. <br />2.5. SEAL AND SIGNATURE OF TRUSS COMPANY ENGINEER OF RESPONSIBLE CHARGE <br />ON ALL TRUSS ENGINEERED SHEETS OR DRAWINGS. <br />2.6. NAME AND TRADE MARK OF PLATE MANUFACTURER AND TRUSS FABRICATOR AS <br />WELL AS PROJECT NAME AND LOCATION. <br />2.7. UNIFORM, LATERAL, AND CONCENTRATED LOAD REQUIREMENTS AND NOTED ON <br />PLANS AND/OR CORRESPONDING DETAILS. <br />2.8. ALL TRUSS CONNECTION HARDWARE REQUIREMENTS. <br />2.9. ALLOWABLE LOADS FOR STRESS GRADE LUMBER AND PLATES AS ALLOWED BY <br />AND I.C.B.O. INCLUDING I.C.B.C. REPORT NUMBER. <br />3. FIELD REPAIR OF DAMAGED TRUSSES MUST BE APPROVED IN WRITING BY THE TRUSS <br />ENGINEER AND ENGINEER OF RECORD. <br />4. ALL ROOF TRUSS BEARING SHALL HAVE METAL FASTENERS TO RESIST UPLIFT FORCES AS <br />NOTED ON ROOF FRAMING PLAN. GROSS UPLIFT PRESSURE DIAGRAM ON SHEET <br />5. TRUSS SUPPLIER IS TO PROVIDE PLAN AND PROCEDURES FOR NAILING, SECURING AND <br />BRACING OF ALL TRUSSES. THE CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY <br />BRAZING FOR THE TRUSSES DURING ERECTION. <br />6. TRUSS SUPPLIER SHALL PROVIDE TRUSS CAPABLE OF TRANSFERRING LATERAL AS NOTED <br />ON PLANS AND/ OR DETAILS. <br />7. APPROVED TRUSS PLANS SHALL BE AVAILABLE ON JOB SITE DURING THE INSPECTION. <br />8. TRUSS MANUFACTURER SHALL COORDINATE TRUSS LAYOUT WITH MECHANICAL/ PLUMBING <br />DRAWINGS FOR ADDITIONAL CONCENTRATED LOADS DUE TO DOMESTIC WATER AND <br />SPRINKLE PIPE SUPPORTS. <br />9. TRUSS MANUFACTURER SHALL COORDINATE TRUSS LAYOUT WITH MECH/PLUMBING <br />DRAWINGS TO ALLOW ALL PIPES AND DUCT ADEQUATE SPACE FOR PROPER INSTALLATION. <br />THE MANUFACTURER SHALL COORDINATE THE WEB MEMBER CONFIGURATION WITH THE <br />MECHANICAL DRAWINGS AND ARCHITECTURAL DRAWINGS SUCH THAT ADEQUATE OPENING <br />IS PROVIDED FOR ANY MECHANICAL UNITS AND DUCTS AND AND ACCESS CATWALKS. <br />10. TRUSSES SHALL BE SPACED AS SHOWN ON THE PLANS. LESSER SPACING MAY BE USED IF <br />REQUIRED BY THE TRUSS DESIGNER. ACTUAL TRUSS SPACING SHALL BE USED TO <br />APPLICABLE WIND LOAD AT THE PROJECT SITE WITH THE DEAD LOAD SHOWN ABOVE, IN <br />ACCORDANCE WITH THE COMBINATIONS AND PRESSURE AND SUCTION FACTORS INDICATED <br />IN THE APPLICABLE BUILDING CODE. UPLIFT INDICATED IS ONLY A MINIMUM. <br />11. SEE PLANS FOR TRUSS LOCATIONS AND SPANS. <br />12. TRUSS DESIGN LOADS SHALL BE AS FOLLOWS: <br />TYP UNIT PRIVATE STORAGE <br />ROOF FLOOR BALCONY AREA <br />TOP CHORD LIVE LOAD 20 PSF 40 PSF 60 PSF 125 PSF <br />TOP CHORD DEAD LOAD 15 PSF 25 PSF 35PSF 25 PSF <br />BOTTOM CHORD LIVE LOAD 0 PSF 0 PSF 0 PSF 0 PSF <br />BOTTOM CHORD DEAD LOAD 5 PSF 5 PSF 5 PSF 5 PSF <br />TOP CHORD UPLIFT LOAD 10 PSF 0 PSF 0 PSF 0 PSF <br />13. ENVIRONMENTAL LOADING, INCLUDING BUT NOT LIMITED TO WIND LOADING, SEISMIC <br />LOADING, RAIN LOADING, ETC. SHALL BE THE RESPONSIBILITY OF THE TRUSSES DESIGNER. <br />14. TRUSSES DESIGNER SHALL REFER TO SHEET S200 FOR WIND UPLIFT LOADING ON ROOF <br />BASED ON WIND ZONE. <br />15. SEE PLAN FOR CONCENTRATED LOADS. <br />16. TRUSS DESIGNER SHALL APPLY LIVE LOAD TO BOTTOM CHORD OF TRUSS AS REQUIRED BY <br />CODE <br />17. TRUSSES DESIGNER SHALL COORDINATE w/ MECH. PLANS TO VERIFY NO CLASHES w/DUCT <br />WORK & OR JOIST BRIDGING. <br />18. THE ABOVE NOTED VALUES ARE MINIMUM REQUIREMENTS FOR DEAD AND LIVE LOADS. SEE <br />SHEET S200 FOR WIND ROOF PRESSURE REQUIREMENTS. <br />19. TOP CHORD DEAD LOAD SHOWN ABOVE INCLUDES 3 PSF FOR TRUSS -SELF WEIGHT. TRUSS <br />DESIGNER SHALL INCREASE DEAD LOAD, AS REQUIRED. <br />20. MEMBERS OF THE GABLE END WALL TRUSSES SHALL BE DESIGNED FOR COMPONENT WIND <br />FORCES AGAINST THE EXPOSED FACE OF THE TRUSS. <br />21. MAXIMUM LIVE LOAD DEFLECTION FOR FLOOR TRUSSES L/480 <br />22. MAXIMUM LIVE LOAD DEFLECTION FOR ROOF TRUSSES L/240 <br />23. MAXIMUM LIVE LOAD DEFLECTION FOR ALL CANTILEVERED TRUSSES = CANTILEVER <br />LENGTH/ 180. <br />24. ALL TRUSS FRAMING CONNECTIONS TO WALLS, GIRDER TRUSSES, LEDGERS, BEAMS OR <br />OTHER SUPPORTS, SHALL BE MADE WITH JOIST HANGERS. TIE DOWNS, FRAMING ANCHORS, <br />POST CAPS, ETC,: AND SHALL BE SIZED AND ATTACHED OVER THE FRAMING ANCHORAGE <br />MANUFACTURER'S RECOMMENDATIONS. IN COMBINATION WITH INFORMATION ON THESE <br />DRAWINGS. <br />25. ALL HEADERS, BEARING WALLS AND POSTS SHOWN ON THE PLANS SHALL BE USED FOR <br />BEARING IN DESIGN OF THE FLOOR AND ROOF TRUSSES. <br />26. WHERE DRAFT STOPS ARE REQUIRED BY THE ARCHITECTURAL DRAWINGS, PROVIDE A <br />MINIMUM OF 2x4 VERTICAL AT 24" ON CENTER BETWEEN TRUSS TOP AND BOTTOM CHORDS <br />AND WEB MEMBERS, AS REQUIRED, FOR DRAFT STOP NAILING. <br />27. ALL TRUSS TO TRUSS AND TRUSS TO BEAM CONNECTIONS SHALL BE DESIGNED BY TRUSS <br />MANUFACTURER. <br />28. LOADS INDICATED HEREIN SHALL BE UTILIZED IN THE DESIGN OF ROOF GIRDER, HIP AND <br />JACK TRUSSES, AS REQUIRED. <br />ASCE 7-16 WALL DESIGN ALLOWABLE COMPONENTS <br />AND CLADDING WIND PRESSURES AND SUCTIONS <br />FOR MEAN ROOF HEIGHT5 60 ft <br />EFFECTIVE <br />WIND AREA <br />NOMINAL GROSS UPLIFT DESIGN <br />NOMINAL WALL DESIGN <br />(SQ FEET) <br />PRESSURES (PSF) <br />WIND PRESSURES AND <br />SUCTIONS (PSF) <br />AREA <br />03 <br />05 <br />10-19.99 <br />10.0 <br />-21.2 <br />10.0 <br />-35.6 <br />10.0 <br />-53.5 <br />19.4 <br />-21.0 <br />19.4 <br />-25.9 <br />20-49.99 <br />10.0 <br />-20.7 <br />10.0 <br />-31.8 <br />10.0 <br />-44.4 <br />18.5 <br />-20.1 <br />18.5 <br />-24.1 <br />50-99.99 <br />10.0 <br />-20.0 <br />10.0 <br />-26.8 <br />10.0 <br />-32.1 <br />17.4 <br />-19.1 <br />17.4 <br />-21.9 <br />100 & OVER <br />10.0 <br />-19.4 <br />10.0 <br />-23.0 <br />10.0 <br />-23.0 <br />16.5 <br />-18.2 <br />16.5 <br />-20.1 <br />COMMENTS: VALUE DENOTES PRESSURE <br />VALUE DENOTES SUCTION <br />RSH IENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT < 25 ft <br />WIND SPEED (ULTIMATE) 140.0 MPIH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 27 DEG. <br />WIND AREA VALUE DENOTES PRESSURE [4:12]-[6:12] <br />(SQ FEET) (-) VALUE DENOTES SUCTION a=4ft <br />AREA I ROOF 1 2e 2n 2r 3 3e 3r a <br />LJID '29Z QA AQ CZ7 AQ rZ-7 _AQ r7 <br />10 C�GABLE -38.22 -38.22 -60.99 -60.99 -60.99 -78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONESISHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-03 (10d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-03 (10d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-03 (10d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: 1V32" EXP. 1 (4%0) <br />TILE: 1%2" EXP. 1 (4%0) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1V32", SHEATHING SHALL BE FASTENED AAk 0 <br />WITH ASTM F1667 RSRS-03 10d (2Y2"x 0.131") NAILS OR ASTM F1667 RSRS-04 (3"x.120") NAILS 71 <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTILOOKER a=4ft <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING GABLE ROOF > 20 TO 27 DEG. <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS [4:12]-[6:12] <br />W1 BLOCKING PER NAILING SCHEDULE. <br />C1) <br />C:) <br />0- i to <br />Z <br />Z <br />Z <br />4 j <br />Z <br />(D <br />U) <br />LLJ <br />0 <br />V) <br />F- <br />0 U) <br />Lu Ili <br />c F Lo 2 <br />E J 04 Ce) <br />0 C14 <br />Cc _j Cj <br />= LL <br />11i CID <br />:3 -6 C9 <br />0 a r- <br />< 0 <br />r) Co <br />Cq 2 <br />Ij c B <br />last" <br />A I <br />BD. <br />THIS DOCUMENT AND/OR THE DESIGN CONCEPTS <br />EXPRESSED HEREIN ARE THE PROPERTY OF <br />KEESEE ASSOCIATES AND ALL RIGHTS OF <br />OWNERSHIP, INCLUDING COPYRIGHT OF <br />INTELLECTUAL PROPERTY, ARE RESERVED. THE <br />REPRODUCTIONS, COPYING, OR USE OF THIS <br />DOCUMENT AND/OR THE DESIGN CONCEPT <br />WITHOUT THE WRITTEN CONSENT OF KEESEE <br />ASSOCIATES IS STRICTLY PROHIBITED AND <br />PROTECTED BY UNITED STATES AND <br />INTERNATIONAL LAW. <br />V. FOS <br />0 ENGINEERING ASSOCIATEE <br />258 Southhall Lane, Suite 200 <br />Maitland, FL 32751 <br />0: 321-972-0491 F: 407-880-2304 <br />Certificate Of Authorization No. 9161 <br />[I CARL A. BROWN, PE - FL # 56126 <br />El LUIS PABLO TORRES, PE - FL $*87864 <br />[I SCOTT A LEWKOWSKI, PE - FL #78750 <br />TO THE BEST OF THE ENGINEERS KNOWLEDGE, INFORMATION, <br />AND BELIEF. THE STRUCTURAL PLANS AND SPECIF <br />-"I ATIONS <br />CONTAINED WITHIN THESE DRAWING� <br />I EDITI <br />FLORIDA BUILDING CODE- RE_ , EDT," <br />ENGNEER'S SIGNATURE <br />STRUCTURAL ENGINEERING F�STOII <br />BEARINGENON&S I If All 1. <br />Of <br />4 <br />L 0 <br />0 ...... <br />A' <br />'63 S <br />10 N <br />DATE: January 27,'2022' <br />IF SEAL AND SIGNATURE ARE NOT BLUE OR CAN NOT BE <br />SMUDGED CONTACT THEE. OR FOR AUrTHORIZATION <br />Uj <br />0 <br />LLJ Z < <br />Ix <br />0 <br />0 C, <br />U_ <br />LLI <br />U) 0. N <br />F_ <br />F_ <br />0 <br />100 <br />REV. REV. REV. <br />.NO. DESC. DATE <br />REVISIONS <br />Project Number: 21-7431 <br />Date: <br />Issue Date: 01/26/22 <br />Reviewed By: SL <br />Drawn By: CM <br />Scale: As indicated <br />Sheet Name: <br />GENERAL <br />STRUCTURAL NOTES <br />& ABBREVIATIONS <br />Sheet No. <br />S002 <br />