My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6598 Bar S Bar Trl (3)
Zephyrhills
>
Building Department
>
Building Plans
>
6598 Bar S Bar Trl (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:56:01 PM
Creation date
2/19/2025 1:02:24 PM
Metadata
Fields
Template:
Building Plans
Street #
6598
Location
Bar S Bar Trl
Contractor
Windward Building Group
Building Plans - Permit #
3585
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A600 <br />1 <br />I <br />0 <br />0 <br />G <br />LEGEND <br />SYMBOL DISTRIBUTION <br />• PATH OF EXIT <br />FE FIRE EXTINGUISHER - G.C. TO <br />c11,, COORDINATE FINAL LOCATION WITH <br />FIRE MARSHALL <br />I <br />NOTES <br />ti EXIT LIGHT SIGN REFER TO MEP <br />DRAWINGS <br />EMERGENCY LIGHTING <br />d CEILING PACK <br />REFER TO MEP <br />DRAWINGS <br />EACH 3'-0" DOOR ALLOWS 180 PERSONS TO EXIT/PER NFPA (TYP.) <br />EACH 6'-0" DOOR ALLOWS 360 PERSONS TO EXIT/PER NFPA (TYP.) <br />* KEYNOTE <br />L PANIC HARDWARE TO BE PROVIDED PER NFPA <br />12.2.2.2.3 <br />EXIT---i <br />�— --RAISED BORDER <br />5/8" MIN. - 2" MAX HIGH RAISED <br />CHARACTERS <br />- - GRADE 2 BRAILLE (TYP.) <br />2 A6o1 SIGNS SHALL BE DESIGNED AND <br />A600 �'2` ' INSTALLED IN ACCORDANCE WITH <br />i EXIT NFPA 101, SECT 7.10.1.3 AND <br />ICC/ANSI A117.1 SECT 703.3-703.4 <br />TABLE TENNIS III NOTE: <br />0' - 0" ( 101 _ ) 0' _ 0,., 1. ALL COPY AND GRAPHICS SHALL BE RAISED 1/32" <br />2. LETTER FORM SHALL BE SANS SERIF <br />EXIT DOOR IDENTIFICATION DETAIL <br />FE - SCALE: NTS <br />'1 <br />A601 <br />LIFE SAFETY PLAN <br />�1 <br />GROSS AREA TABULATION <br />AREA NAME SQUARE FT. <br />GAME ROOM + STORAGE 1309 SF <br />ENTRYWAY 50 SF <br />TOTAL SQUARE FOOTAGE 1359 SF <br />11 r <br />:n <br />NOTE: <br />-� GC TO COORD. TYPE AND LOCATION OF <br />ALL FIRE EXTINGUISHERS WITH LOCAL <br />FIRE CHIEF PRIOR TO INSTALLATION <br />----------PROVIDE WALL BLOCKING SUPPORT <br />WHERE REQUIRED <br />WALL MOUNTED EXTINGUISHER <br />AMEREX MODEL #2160 WITH MOUNTING <br />BRACKET LOCATED IN KITCHEN, IN <br />PUBLIC AREAS PROVIDE AS INDICATED <br />-- ON PLANS LB-4A60BC FIRE <br />EXTINGUISHERS WITH MOUNTING <br />BRACKET (COORDINATE LOCATIONS <br />WITH FIRE MARSHALL) <br />FIRE EXTINGUISHER DETAIL <br />SCALE: NTS <br />PLAN NORTH TRUE NORTH <br />0 2' 4' 8' <br />7%w"M%Mmmmm� <br />3/8" = 1 '-0" <br />ROOM OCCUPANCY SCHEDULE <br />ROOM <br />ROOM NAME OCCUPANCY NET ROOM OCCUPANT OCCUPANCY LOAD <br />REQUIRED <br />NUMBER <br />CLASSIFICATION AREA LOAD FACTOR CALCULATED EGRESS WIDTH <br />101 <br />STORAGE STORAGE 94 SO FT 300 SOFT 1 PPL <br />0.2" <br />102 <br />GAME ROOM ASSEMBLY (NON -FIXED SEATS) 1099 SO FT 15 SO FT 73 PPL <br />14.6" <br />TOTALS: 74 PPL <br />14.8" <br />NOTES: TOTAL EGRESS PROVIDED: <br />108" <br />1. SCHEDULE COMPLIES WITH FBC 2020 7TH EDITION TABLE 1004.1.2 <br />2. REQUIRED EGRESS WIDTH IN INCHES FOR STAIRWAYS PROVIDES .3" PER OCCUPANT AS PER FBC 2020 7TH EDITION 1005.3.1 <br />3. REQUIRED EGRESS WIDTH IN INCHES FOR OTHER EGRESS COMPONENTS PROVIDES .2" PER OCCUPANT AS PER FBC 2020 7TH <br />EDITION 1005.3.2 <br />4. ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN AREA HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE <br />PERMITTED TO BE PROVIDED WITH A LATCH OR LOCK ONLY IF THE LATCH OR LOCK IS PANIC HARDWARE OR FIRE EXIT HARDWARE <br />AS PER NFPA 101.12.2.2.2.3 <br />0'�?® <br />z o <br />— o <br />z N <br />zQ <br />a <br />V ) <br />Lu <br />cli <br />co U cn <br />J N CC0 <br />N <br />i o �c J <br />L OCO <br />U vim, ��ao <br />N O C I- <br /><000�� <br />N � � <br />A I Ncunc <br />THIS DOCUMENT AND/OR THE DESIGN CONCEPTS <br />EXPRESSED HEREIN ARE THE PROPERTY OF <br />KEESEE ASSOCIATES AND ALL RIGHTS OF <br />OWNERSHIP, INCLUDING COPYRIGHT OF <br />INTELLECTUAL PROPERTY, ARE RESERVED. THE <br />REPRODUCTIONS, COPYING, OR USE OF THIS <br />DOCUMENT AND/OR THE DESIGN CONCEPT <br />WITHOUT THE WRITTEN CONSENT OF KEESEE <br />ASSOCIATES IS STRICTLY PROHIBITED AND <br />PROTECTED BY UNITED STATES AND <br />co <br />LLJ <br />CO <br />Gj� 0 <br />y.. <br />Z v <br />I1J <br />'cam' <br />._ _ * <br />* ' - <br />F— o <br />Fr cc <br />G�'JF7 <br />Cr Q <br /><* <br />•� <br />LU <br />Q <br />•.41! <br />Q(n <br />co <br />E <br />r- 20 <br />\ d. <br />Q J <br />UJ <br />C� <br />REV. REV. REV. <br />NO, DESC. DATE <br />REVISIONS <br />Project Number: 21-7431 <br />Date: 1 /25/2022 8:53:40 AM <br />Issue Date_ 01/2622 <br />Reviewed By: SGT <br />Drawn By: NG <br />Scale: As indicated <br />Sheet Name: <br />zLIFE SAFETY PLAN <br />Sheet No. <br />LS1 00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.