ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />I <br />i <br />I <br />I <br />I <br />I <br />I <br />i <br />---------------------------------------------- <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />METER <br />MAIN <br />O <br />200 amp <br />150 amp <br />NEMA1 <br />200 AMP <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />f� <br />W.P. <br />KG.F.L <br />$3 <br />?4 <br />$R <br />#P.C. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />,ql 3" VTR <br />1 I 2" VTR III <br />I <br />SINK! I I KITCHEN <br />I I SINK W/ STUDOR <br />I <br />I 3I' III 2" VTR I I I <br />WC 3" <br />3„ TUB 3"1 <br />3rr <br />1.5" VTR III, 3" SHWR 2„ i i �,� 3rr SINK <br />WC <br />I 3" 1 <br />3" 1 TUB <br />3" 3rr 1 <br />SINK I I <br />HANSON BOX <br />WC <br />4" TUB <br />22 <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR <br />DISPOSAL <br />i FI 2 X 4 FL. GFI <br />I <br />UNDER II <br />CNTR TOP i I I� <br />II <br />PENDANT LJ 2 X 4 FL. GFI <br />LIGHTS OVER / <br />ISLAND <br />lolol <br />i <br />r; 6j€ <br />3 PFI <br />-- --- <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />OPTIONAL LIGHTING <br />SCALE: %4'=V-0" <br />C/O <br />A/C PAD <br />WP <br />GPI + DISCONNECT <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />ALT. <br />I A/C I <br />I� PAD �I <br />rnrZvvint 1_\0 rcn <br />_ SPECS _ <br />ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />o LO <br />z_M <br />0 <br />Z Co <br />Z <br />Q <br />O <br />J <br />0_ <br />z <br />O <br />n� <br />W <br />Cf9 <br />W <br />/�-J <br />� V Q <br />'U <br />— <br />OLLI <br />L <br />O <br />CD <br />�� ~ <br />U <br />mr <br />M <br />W <br />r cu M <br />cC\I <br />U <br />0 o <br />= ai <br />UN <br />-u-OD <br />Y <br />Sao <br />to O : <br />Qrn <br />o` Qo <br />A <br />B D. <br />N•C B D c <br />N U'3 <br />M <br />o co C'V <br />LO � <br />.w <br />V N N <br />�/i d <br />Z Z <br />Zow Z N�� <br />5 <br />N Mp 6 <br />a <br />wLU <br />a a <br />¢�LL�o <br />W <br />�W <br />Z_05'02 <br />N 15 <br />m <br />yZ��� <br />&L <br />m <br />¢' <br />IW Q N M r <br />J <br />°U <br />U m <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z fV <br />O a� <br />1-4 :4' O <br />V) M O^ <br />-4 M <br />Z <br />Q (nfuLn <br />CL (n <br />0n <br />Ln <br />a L_ L <br />ClCn <br />lJ fl. G�0 <br />Q <br />E <br />Z <br />WJ <br />C:) <br />d <br />f <br />oZ <br />ED 0 <br />LL <br />wmZZV)(L <br />CJ F— UN p 0 <br />I~Z�Z 0 <br />z> �db Q <br />_ Z w H z <br />z <br />c�zo a w <br />LLJ <br />N 0 O <br />LU N <br />N <br />rl <br />F a0Z@ <br />w=Z <br />�J <br />O <br />rl <br />LPG <br />N <br />Ln <br />rl <br />.J <br />�0< <br />Z <br />azvo <br />�S <br />w�00� <br />H Z m ° <br />Owl <br />Z�E��zz <br />w 0z <br />w p 0 <br />QQ"ua� 80 <br />W <br />`� <br />OO waF-� <br />0i <br />`� <br />U <br />LL <br />L LLJ°LLZ <br />>> oo <br />NNtnCY <br />�°Za <br />O <br />d- <br />d" <br />J��w <br />aQ~� <br />z <br />N U <br />.. <br />W <br />j <br />J <br />Z <br />Z <br />a W <br />SCALE : AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: MJAMES <br />VERSION NO. <br />106 <br />JOB NO: 16-6653 <br />SHEET NO. <br />3 <br />