My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6601-6607 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6601-6607 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:05:28 PM
Creation date
2/19/2025 1:03:43 PM
Metadata
Fields
Template:
Building Plans
Street #
6601-6607
Location
Gall Blvd
Contractor
SL2 Consulting LLC
Building Plans - Permit #
2998
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL PLUMBING NOTES: <br />GENERAL <br />I. THE BUILDING SHALL BE PROVIDED WITH THE FOLLOWING SYSTEMS: <br />A. A COMPLETE COLD WATER AND HOT WATER SYSTEM. <br />B. A COMPLETE SANITARY, WASTE AND VENT SYSTEM. <br />2. MANUFACTURERS AND MODEL NUMBERS SHOWN IN THE CRITERIA ARE USED <br />AS A BASIS OF DESIGN, WITH OTHER APPROVED MANUFACTURERS NOTED. <br />SUBSTITUTION FOR THE BASIS OF DESIGN ITEMS IS SUBJECT TO THE <br />WRITTEN APPROVAL OF THE ARCHITECT ON AN APPROVED EQUAL BASIS <br />WATER PIPING <br />I. WATER PIPING SHALL BE TYPE "L' COPPER, WITH 95-5 SILVER SOLDERED <br />JOINTS. CPVC MAY BE USED AS AN ALTERNATE <br />2. INSULATE ALL HOT WATER PIPING WITH I" RIGID FIBERGLASS OR /2' <br />FLEXIBLE FOAM INSULATION (ARMAFLEX). FLEXIBLE FOAM INSULATION <br />SHALL NOT BE SPLIT, AND SHALL BE TAPED AT THE BUTT JOINTS. <br />3. PROVIDE EACH FIXTURE WITH STOPS AND SUPPLIES. EXPOSED STOPS <br />SHALL BE CHROME PLATED. <br />4. PROVIDE WATER HAMMER PROTECTION AT EACH FIXTURE, OR GROUP OF <br />SIMILAR FIXTURES. <br />5. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE. <br />6. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS. PRIMERS SHALL BE <br />LOCATED IN A SERVICEABLE LOCATION. <br />7. STERILIZE WATER PIPING IN ACCORDANCE WITH THE HEALTH DEPARTMENT <br />REGULATIONS AND AMERICAN WATER WORKS ASSOCIATION'S SPECIFICATIONS. <br />SANITARY PIPING <br />I. SANITARY, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC, UNLESS <br />PROHIBITED BY THE LOCAL CODES. <br />2. IF PVC PIPING IS PROHIBITED UNDER -GROUND, BY THE LOCAL CODES, <br />THEN SANITARY WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT <br />CAST IRON. LEADED JOINTS, TYLER "TY-SEAL' AND 'NO -HUB' ARE <br />APPROVED SUBJECT TO APPROVAL BY THE BUILDING OFFICAL. <br />3. IF PVC PIPING IS PROHIBITED ABOVE -GROUND BY THE LOCAL CODES, <br />THEN SANITARY, WASTE, AND VENT PIPING SHALL BE SERVICE WEIGHT <br />CAST IRON. LEADED JOINTS, TYLER "TY-SEAL' AND 'NO -HUB" ARE <br />APPROVED SUBJECT TO APPROVAL BY THE BUILDING OFFICIAL. <br />4. AN APPROVED ALTERNATE FOR ALL SANITARY, WASTE AND VENT PIPING <br />IS DWV COPPER WITH 50-50 TIN LEADED SOLDERED JOINTS. <br />5. SLOPE OF SANITARY AND WASTE PIPING SHALL BE 1/4' PER FOOT MINIMUM. <br />6. EXPOSED WASTE DRAINS, IN TOILETS, SHALL BE CHROME PLATED <br />BRASS, WITH MATCHING STOPS AND ESCUTCHEONS. <br />7. ROOF PENETRATIONS SHALL BE WITH LEAD PIPE ROOF JACKS. <br />PLUMBING LEGEND <br />CW <br />NEW COLD WATER <br />BALANCING VALVE <br />HW - - - <br />NEW HOT WATER <br />-jam- <br />CHECK VALVE <br />WHY 7=r <br />WALL HYDRANT <br />-DNS <br />GLOBE VALVE/BALL VALVE <br />HB - <br />HOSE BIB <br />t _ <br />IN LINE PUMP <br />--ilE- <br />UNION <br />-HWR - <br />HOT WATER RECIRCULATED <br />-- <br />GATE VALVE <br />- G <br />NATURAL GAS LINE <br />SOIL OR WASTE <br />BFG <br />BELOW FINISHED GRADE <br />- - - - - - - <br />VENT <br />BFF <br />BELOW FINISHED FLOOR <br />CW- <br />EXISTG COLD WATER <br />AFC <br />ABOVE FINISHED CEILING <br />HW - <br />EXISTG HOT WATER <br />ate- <br />P-TRAP <br />- GL <br />GREASE LINE <br />SS <br />SANITARY SEWER <br />WHA �Q, <br />WATER HAMMER ARRESTOR <br />OM <br />WATER METER <br />FD 02 <br />FLOOR DRAIN <br />G <br />PIPE TURNED DOWN <br />FS �-F- <br />FLOOR SINK <br />@I--- <br />PIPE TURNED UP <br />HD QC-}- <br />HUB DRAIN <br />END OF PIPE <br />FCO}- <br />FLOOR CLEANOUT <br />WH <br />WATER HEATER <br />COTG <br />CLEANOUT TO GRADE <br />J <br />P-TRAP <br />WCO Fa— <br />WALL CLEANOUT <br />WALL MOUNTED LAVATORY <br />CO ��- <br />END OF LINE CLEANOUT <br />VTR <br />VENT THRU ROOF <br />DRINKING FOUNTAIN <br />NTS <br />NOT TO SCALE <br />® <br />OR WATER COOLER <br />RWL <br />RAIN WATER LINE <br />,WHY <br />WALL HYDRANT <br />Oo <br />TANK TYPE WATER CLOSET <br />L• <br />WHYS <br />d <br />I' CW UG FROM METER <br />AND BFP - SEE CIVIL <br />PLANS <br />PL UMBING KEYNOTES <br />O1 4' SAN SEWER STUB -IN LOCATION (FUTURE CONNECTION) <br />O2 STUB IN FOR FUTURE ADA TOILET ROOM <br />INSTALL FLOOR DRAIN <br />O3 STUB IN FOR FUTURE ADA WATER FOUNTAIN <br />4O STUB IN FOR FUTURE MOP SINK AND BREAKROOM SINK <br />O5 RUN PVC TO WALL HYDRANT DOWN IN WALL <br />PLUMBING SCOPE <br />I. STUB IN AND INSTALL UG SANITARY SEWER <br />LINES AS SHOWN <br />2. CONNECT NEW SANITARY SEWER LINES INTO <br />SERVICE LINES AT S1TE <br />3. FIELD VERIFY ALL PLUMBING WASTE LINE DEPTHS <br />AND SUPPLY LINE SIZES. MAKE ADJUSTMENTS <br />AS NECESSARY AND AS PER PLUMBING CODE <br />0 <br />z <br />4' SAN SEWER - SEE CIVIL <br />PLANS FOR CONTINUATION <br />1 <br />CO <br />NO SLAB IN THIS AREA <br />I <br />I <br />I <br />I <br />ai I <br />I'PVC CW UP ALONG WALL <br />INTO ATTIC SPACE W/ SHUT-OFF <br />VALVE AND CAP <br />•- --- - - -- -- ^. C --- --- WHY <br />�------ - - - -- - -- <br />5 <br />i <br />I' CW UG FROM METER <br />AND BFP - SEE CIVIL <br />PLANS <br />PLUMBING <br />FLOOR PLAN <br />SCALE 1/8" = 1'-0" <br />PLUMBING NOTES: <br />I. ALL PLUMBING WORK SHALL BE IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE, 2020 <br />FLORIDA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES AND ORDINANCES. <br />2. GENERAL CONTRACTOR SHALL INCLUDE ALL WORK REQUIRED FOR A COMPLETE INSTALLATION <br />AND FOR PROPER OPERATION OF MECHANICAL AND PLUMBING SYSTEMS. INCLUDING ALL <br />WORK REQUIRED BY CODE OR REGULATORY AGENCIES. <br />3. SEE SHEET GI.2 FOR ADDITIONAL TOILET ROOM NOTES AND DIMENSIONAL INFORMATION <br />4. ALL PLUMBING FIXTURES SHALL COMPLY WITH FLORIDA BUILDING CODE 2020 401-426. PROVIDE <br />FIXTURE AND FAUCET COMPLIANCE WITH MAXIMUM WATER CONSUMPTION RATES PER <br />FLORIDA BUILDING CODE PLUMBING 604.4 <br />5. PROVIDE TEMPERED HOT WATER FOR ACCESSIBLE HAND WASHING LOCATIONS <br />PLUMBING FIXTURE SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />MANUF. <br />MODEL NO. <br />CW <br />HW <br />WASTE <br />VENT <br />HEIGHT <br />MAX.WATER <br />COLOR <br />REMARKS <br />USAGE <br />FINISH <br />WHY <br />WALL HYDRANT <br />WOODFORD <br />OR EQUAL <br />WOODFORD <br />B65 <br />3/4' <br />24"AFF <br />.70 GAL/MIN <br />BRASS <br />WITH SHUTOFF VALVE & VACUUM BREAKER <br />FD <br />FLOOR DRAIN <br />AT CONTR <br />OPTION <br />AT CONTR <br />OPTION <br />4" <br />BRASS <br />LIGHT COMMERCIAL FLOOR DRAIN <br />PLUMBING <br />MATERIAL <br />SCHEDULE <br />SOIL, WASTE, VENT <br />PIPING <br />WATER PIPING <br />INSULATION DATA <br />CLEANOUT DATA <br />FLOOR (FCO) <br />WALL (WCO) <br />OUTSIDE (COTG) <br />EXTERIOR BULDING SERVICE <br />INTERIOR BELOW GRADE <br />INTERIOR ABOVE GRADE <br />TYPE <br />THICKNESS <br />LOCATION <br />MANUF. <br />MODEL NO. <br />MANUF. <br />MODEL NO. <br />MANUF <br />MODEL NO. <br />SCHEDULE 40 PVC WITH <br />SOLVENT WELD PVC <br />FITTINGS; IF APPROVED BY <br />LOCAL CODES <br />PVC SCHEDULE 40 <br />CPVC TUBING 'FLOWGUARD <br />GOLD' MEETING ASTM D2846 <br />CPVC TUBING 'FLOWGUARD <br />GOLD' MEETING ASTM D2846 <br />ARMSTRONG AP <br />ARMAFLEX <br />I" THICK <br />ALL HOT & COLD WATER <br />PIPING IN NON -CONDITIONED <br />AREAS <br />WADE <br />W-6030- <br />SV-2TS; <br />J.R. <br />SMITH <br />4420 <br />W/STAINLESS <br />STEEL <br />COVER <br />WADE <br />W-6030- <br />SV-2 <br />FIBERGLASS <br />I" THICK <br />STORM WATER PIPING <br />ABOVE GRADE <br />WATER HAMMER ARRESTORS <br />VALVES <br />PIPE HANGERS <br />BACKFLOW <br />DEVICE <br />WATER <br />METER <br />PIPE <br />PENETRATIONS <br />REMARKS <br />BALL <br />GATE <br />CHECK <br />MANUF. <br />MODEL NO. <br />TYPE <br />LOCATION <br />MANUF. <br />MODEL NO. <br />MANUF. <br />MODEL NO. <br />MANUF. <br />MODEL NO. <br />PRECE- <br />CISION <br />SC500 <br />"A' <br />AS REO'D <br />ON DWGS. <br />OR CODE; <br />SEE SPECS. <br />HAMMOND <br />806 <br />NIBCO <br />T113 <br />SI13 <br />HAMMOND <br />915 <br />IN COMPLIANCE WITH 2O04 <br />FLORIDA PLUMBING CODE <br />HAYS <br />MODEL NO. <br />40301 <br />WILKINS <br />MODEL NO. <br />975 PER <br />SPECS <br />METACAULK <br />UL-CAJ2134 <br />UL-WL2135 <br />VERIFY ALL METER <br />LOCATIONS & SIZES AT SITE <br />Revisions <br />Date <br />T y) <br />Mark A. jonnatti <br />Florida AR 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 S Hyjhway 19 N <br />Clea er, orida 33765 <br />(727) 25-ARCH <br />(727) 725-2603 fx <br />www.jarch.com <br />info@jarch.com <br />® Jonnatti Architecture <br />Incorporated 2021 <br />OF Ft <br />�: • J.:y <br />�A _ <br />a/31/21 <br />ZEPHR <br />RETAIL <br />DEVELOPMENT <br />US HWY 301 <br />GALL BLVD <br />ZEPHYRHILL S <br />FLORIDA <br />33542 <br />PLUMBING <br />PLAN <br />(`Zraw7nMAI <br />Check <br />MAI <br />Date <br />AUG 18, 2021 <br />Scale <br />AS NOTED <br />Job No <br />ZEPHR RB <br />
The URL can be used to link to this page
Your browser does not support the video tag.