My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6601-6607 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6601-6607 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:05:28 PM
Creation date
2/19/2025 1:03:43 PM
Metadata
Fields
Template:
Building Plans
Street #
6601-6607
Location
Gall Blvd
Contractor
SL2 Consulting LLC
Building Plans - Permit #
2998
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I- <br />11 ILL ' 1't _ 1, !'' rjyi : 1, _ I I I , I IL - 1 - I I <br />130'-0' <br />60'X60' <br />60"X60' <br />60'X60' <br />60"X60" 60'X60' <br />ESSENTIALY <br />ESSENTIALY <br />ESSENTIALY <br />ESSENTIALY ESSENTIALY <br />LEVEL AREA <br />LEVEL AREA <br />LEVEL AREA <br />LEVEL AREA LEVEL AREA <br />180, <br />`,18 <br />80 / <br />0, <br />/ <br />L89, <br />/ <br />- <br />- ..}: <br />I <br />e <br />, <br />1 <br />I <br />" <br />i <br />t <br />1 <br />1 <br />1 <br />I <br />1 <br />1 <br />, <br />j <br />2-HR RATED TENANT <br />> <br />I <br />SEPARATION PARTITION <br />, <br />VACANT LEASEABLE <br />A <br />' <br />VACANT LEASEABLE <br />4,000 SO FT <br />1 <br />1 <br />2,500 SO FT pr 1 <br />I <br />I <br />. <br />I <br />1 <br />.. <br />t <br />/ <br />--1 <br />- ---- <br />--- - <br />----- <br />-- <br />---------- <br />---_j <br />- <br />- -- 1 <br />60'X60' <br />60' <br />60" <br />6 <br />"X60" <br />ESSENTIAL <br />ES <br />ENTIALY <br />E <br />SENTIALY <br />LEVEL ARE <br />LE <br />EL AREA <br />LEVEL <br />AREA <br />LIFE SAFETY LEGEND <br />® ILLUMINATED EXIT SIGN - SINGLE FACE <br />WITH DIRECTIONAL ARROW (IF REQUIRED BY LOCATION) <br />Z ILLUMINATED EXIT SIGN - DOUBLE FACE <br />WITH DIRECTIONAL ARROW (IF REQUIRED BY LOCATION) <br />COMBINATION ILLUMINATED EXIT SIGN AND EMERGENCY <br />LIGHT FIXTURE <br />FIRE EXTINGUISHER - 2AIOBC FIRE EXTINGUISHER PER NFPA-I, <br />FE NFPA-10 AND NFPA 101 SECTION 9.9 SURFACE MOUNT UNITS WHERE <br />SHOWN AND MAXIMUM 75 FEET FROM ANY POINT IN THE SUITE <br />35' R TRAVEL DISTANCE AND ROUTE TO EXIT FROM THE MOST <br />3S' F ) REMOTE POINT ( F = FRONT EXIT, R = REAR EXIT) <br />rEXIT CAPACITY BASED ON EXIT WIDTH X 0.2 INCHES / OCCUPANT <br />OCCUPANCY CALCULATION <br />GROSS BUILDING AREA = 6,000.0 SO FT <br />OCCUPANCY TYPE AREA LOAD OCCUPANTS <br />MERCANTILE OCCUPANCY 6,000.0 SF 30 SF/OCC 50 <br />TOTAL OCCUPANTS 50 OCCUPANTS <br />TYPE OF CONSTRUCTION = TYPE VB - UNSPRINKLERED <br />FIREFIGHTER SAFETY WARNING SIGNS FOR STRUCTURES WITH <br />LIGHT -FRAME TRUSS -TYPE, FLOOR end/or ROOF CONSTRUCTION <br />IN ACCORDANCE WITH <br />FLORIDA ADMINISTRATIVE CODES 69A-3.012 <br />(Aldridge - Bongo Firefighter Safety Act) <br />8" Inches <br />s <br />24" Inches <br />Within 24" inches <br />to the left of the <br />main entry door <br />Walking surface or <br />the finished floor to <br />the bottom of the <br />symbol shall be not <br />less than 4' feet <br />Walking surface or <br />the 5nished floor to <br />the top of the symbol <br />shall be not more <br />than 6' feet <br />"MAIN" <br />ENTRY <br />11111191 15S <br />V <br />LIFE SAFETY <br />FLOOR PLAN <br />z SCALE 1/8" = 1'-0" <br />GENERAL NOTES <br />1. CONSTRUCTION FIRE SAFETY STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, <br />OR DEMOLITION OPERATIONS, INCLUDING THOSE IN UNDERGROUND LOCATIONS, SHALL <br />COMPLY WITH NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, <br />AND DEMOLITION OPERATIONS, AND NFPA 1, CHAPTER 16. FIRE PROTECTION DURING <br />CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OUTLINED IN <br />NFPA 1, SEC. 16.4.3.1.1 THROUGH SEC. 16.4.3.3.2.10. FIRE SAFETY DURING DEMOLITION <br />SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OUTLINED IN NFPA 1, SEC. 16.5.1 <br />THROUGH SEC. 16.5.4. <br />2. THE FIRE INSPECTOR MUST PERFORM A FINAL INSPECTION OF THE PROJECT PRIOR TO <br />OCCUPANCY. THE CONTRACTOR MUST COORDINATE A FIRE FINAL INSPECTION WITH <br />THE FIRE SYSTEM CONTRACTORS WHEN CONSTRUCTION IS COMPLETE. WRITTEN <br />APPROVAL OF INSPECTION AND TESTING FROM THE PUBLIC UTILITY IS REQUIRED <br />PRIOR TO OCCUPANCY FOR ANY PUBLIC FIRE HYDRANTS INSTALLED TO SATISFY <br />THE CITY FIRE CODE REQUIREMENTS. <br />Structures with Light -Frame Truss Floor systems shall be marked <br />with the letter "F" <br />Structures with Light -Frame Truss Roof systems shall be marked <br />with the letter "R" <br />Structures with Light -Frame truss Roof and Floor systems shall <br />be marked with the letters "R'F" <br />SIGN PARAMETERS <br />• Symbols shall be weather proof and contrasting with background <br />• Maltese Cross shall be measured 8 Inches horizontally and 8 Inches vertically <br />• Maltese Cross shall be of a bright red reflective color <br />• Maltese Cross shall be within 24 inches to the left of the main entry door <br />• Maltese Cross shall be not less than 4 feet above grade or walking surface <br />• Maltese Cross shall be not more than 6 feet above grade or walking surface <br />• Large or multi -tenant buildings will require multiple signs spaced a (+/-) 100' ft. <br />• Additional signs shall be Installed as determined by the AHJ / Fire Department <br />(AHJ) a Authority Having Jurisdiction <br />Revisions Date By <br />Mark A. jonnatti <br />Florida AR 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Higghway 19 N <br />Clearwater, Florida 33765 <br />(727) 725-ARCH <br />(727) 725-2603 fx <br />www.jarch.com <br />info@jarch.com <br />® jonnatti Architecture <br />Incorporated 2021 <br />OF,FCO <br />g <br />AR 0 <br />8/31/21 <br />ZEPHR <br />RETAIL <br />DEVELOPMENT <br />US HWY 301 <br />GALL BLVD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />LIFE SAFETY <br />Drawn <br />MAI <br />Check <br />MAj <br />Date <br />AUG 18, 2021 <br />Scale <br />AS NOTED <br />job No <br />ZEPHR RB <br />Sheet: <br />
The URL can be used to link to this page
Your browser does not support the video tag.