My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6601-6607 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
6601-6607 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:05:28 PM
Creation date
2/19/2025 1:03:43 PM
Metadata
Fields
Template:
Building Plans
Street #
6601-6607
Location
Gall Blvd
Contractor
SL2 Consulting LLC
Building Plans - Permit #
2998
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF PROJECTION <br />PREMOLDED EVERGUAROP <br />SEALANT POCKET <br />PRIM INSIDE OF SEALANT <br />POCKET (TPO ONLY) <br />EVEROUARD*APPROVED <br />SEALANTS <br />QUICK SET NON -SHRINK GROUT IN <br />POCKET UNDER SEALANT <br />HEAT WELD FLANGE MIN <br />2- (52 mm) <br />............ <br />............... <br />............................ EVERGUARCP REINFORCED <br />MEMBRANE <br />ENERGYGUARD7 ROOF <br />INSULATION <br />ROOF DECKISUBSTRATE <br />1. ALLOW 2* (52 mm) CLEARANCE AROUND THE PROJECTION- IF MULTIPLE PROJECTIONS. ALLOW 1"(25.4 mm) <br />BETWEEN PROJECTION AND POCKET. <br />2. <br />THE EXISTING PROJECTION MUST BE CLEAN OF ALL DEBRIS BEFORE INSTALLATION. <br />3 FOUR DRILL-TEC' PLATES A SCREWS INSERTED AROUND PENETRATION. <br />4. EVERGUARDS POURABLE SEALER POCKET MUST BE PRIMED WITH EvEmumoa TPO PRIMER. (TPO ONLY) <br />5. IF SEALANT POCKET MUST BE CUT. STRIP IN CUT WITH UNREINFORCED TPO OR PVC STRIP MIN 4' <br />(102 mm) WIDE AND RUN OUT ONTO DECK SHEET MINIMUM 2* (52 mm). <br />0.25 YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES. (TPO ONLY) <br />T. IF PLATES AND FASTENERS ENCROACH INTO THE SEAM AREA OF THE POCKET, T <br />TARGET <br />MUST BE ADDED FIRST TO COVER FASTENERS AL SYSTEMS <br />POURABLE SEALANT POCKET DETAIL <br />EVERGUM& 52A <br />N.T.S. 21-19 <br />6 ROOF DETAIL <br />NOT TO SCALE <br />INUOUS PENETRATION <br />OLDER EVERGUARCf SPLIT PIPE BOOT <br />�SEAr CAULK GRADE SEALANT <br />tOUARVD WATER -BLOCK OR <br />SEAL UNDER METAL BAND <br />WELDED LAP <br />REINFORCED MEMBRANE <br />INSULATION <br />I <br />FNO-%l <br />1. FOUR DR[LL-TEC' PLATES & SCREWS AROUND PENETRATION <br />2. IF PLATES AND FASTENERS ENCROACH INTO THE SEAM AREA OF THE POCKET. THEN A TARGET <br />MUST BE ADDED FIRST TO COVER FASTENERS. <br />3.25 YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES. <br />4. APPLY EVERGUARDO TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES <br />(REFER TO EVERGUAROO DETAIL 115). <br />ALL SYSTEMS <br />SPLIT PIPE BOOT DETAIL <br />524 <br />M0 EVERGU <br />I = �.w = I N.T.S. 11-21-191 <br />REINFORCED EVBWUM& TPO <br />MEMBRANIE (PERIMETER SHEET <br />IF REQUIRED) <br />HEAT -WELD MEMBRANE PIECE <br />TO MEMBRANE FLASHING <br />EVERGUAW TPO PREFORMED <br />W410E CORNER HEAT -WELDED <br />HEAT -WELDED LAP <br />LAP <br />DRILL-TEd" PLATES & <br />SCREWS 17 (305 mm) O.C. <br />(6- (152 mm] O.C. FOR <br />BALLASTED SYSTEMS) <br />WOOD MAILER. &4'(31.8 mm x <br />4" (IM ffun) MIN. WIDE <br />SECURED TO DECK (OPTIONAL) <br />ENERGYGUARD7 ROOF <br />INSULATION <br />FN_0TE7I <br />1. FOR INSULATION THICKNESS GREATER THAN Ir (2110 mm). A HARD BOARD IS REQUIRED ON <br />MECHANICAL SYSTEMS ONLY, <br />I FLASHINGS MAY BE ADHERED OR INSTALLED DRY. SEE SPEC FOR DWENSIONS. <br />3. KEEP FASTENERS BACK FROM CORNER Ir V 52 mm) MAX. IN BOTH HORIZONTAL AND VERTICAL APPLICATIONS. <br />4.25 YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES <br />5. IF EVERGUARe FREEDOM' MEMBRANE IS USED. BONDING ADHESIVE <br />IS NOT NEEDED AND WALL MUST BE PRIMED. <br />0. APPLY EVERGUARDS TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES <br />(REFER TO EVERGUARDO DETAIL 115). <br />ALL SYSTEMS <br />INSIDE CORNER REINFORCEMENT - <br />PREFORMED CORNER DETAIL <br />1 � I ;:77B <br />EVERGUAiD <br />- I N.T.S. 11-21-19 <br />Ns <br />ROOF DETAIL <br />r4 <br />ROOF DETAIL, <br />.1.2/ <br />NOT TO SCALE <br />\441.2/ <br />NOT TO SCALE <br />EVERGUARIPWATER BLOCK OR <br />FLEXSEW CAULK GRADE SEALANT <br />DRLL-TEC-7 TERMINATION BAR <br />FASTENED 6- (1 52mm) D.C. <br />FLEXSEAL" CAULK GRADE SEALANT <br />(SEE <br />FLASHING KEY) <br />DRILL.-TEC" PLATES & SCREWS 12' <br />(306 "wn) O.C. (a* (152 mm] D.C. FOR <br />BALLASTED SYSTEMS) <br />HEAT -WELDED LAP <br />REINFORCED EVERGUARCP <br />MEMBRANE (PERIMETER <br />SHEET IF REQUIRED) <br />ENEROYGUARb_ ROOF <br />INSULATION <br />ROOF DECKISUGSTRATE <br />NOTE: <br />1. FOR INSULATION THICKNESS GREATER THAN r (2D3 mm). A HA <br />BOARD IS REQUIRED ON MECHANICALLY FASTENED SYSTEMS Z. -1 <br />2. IF EVERGUARD6 FREEDOM" MEMBRANE IS USED. BONDING ADHESIVE Is NOT <br />NEEDED AND WALL MUST BE PRIMED. <br />3. APPLY EVERGUARD& TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES <br />(REFER TO EVERGUARCP DETAIL 115). <br />WALLICURB FLASHING WITH TERMINATION BAR <br />DETAIL <br />P� � EVERGUAR;���O� I N.T.S. 302 <br />- 0� � � �. - <br />3 ROOF DETAIL <br />i 7 NOT TO SCALE <br />ROOF PLAN <br />SCALE 1/8" = 1'-0" <br />ROOF PLAN NOTES: <br />I. NEW ROOF SYSTEM TO BE GAF EVERGARD TPO 60 MIL MECHANICALLY FASTENED <br />SYSTEM. SYSTEM SHALL BE A SMOOTH TYPE, POLYESTER SCRIM REINFORCED <br />THERMOPLASTIC POLYOLEFIN MEMBRANE WITH A NOMINAL 0.060 INCH (60 MIL) <br />THICKNESS, SINGLE PLY ROOFING MEMBRANE. SYSTEM SHALL MEET OR EXCEED <br />THE MINIMUM REQUIREMENTS OF ASTM D-6878. UL LISTED, FM APPROVED, <br />DADE COUNTY PRODUCT APPROVAL, FLORIDA BUILDING CODE 2020 APPROVED. <br />2. INSTALL A MIN 1/4' COVER BOARD ON THE TOP OF THE plywood AND DIRECTLY <br />BENEATH THE FINISH ROOF MEMBRANE <br />3. ROOF PITCH SHALL BE 1/12 MINIMUM <br />22-GAUGE CONTINUOUS 1400K STRIP SECURED <br />WITH DRILL-TEC- FASTENERS 0 12- (305 mm) D.C. <br />EVERGUAR[f COATED METAL EDGE <br />RING SHANK GALVANIZED NAIL Q 4- <br />(102 mm) D.C. STAGGERED OR DRIU-TECH <br />SCREWS IZ* (305 mm) O.0 2- (52 mm) <br />MINIMUM FROM OUTSIDE EDGE OF METAL <br />HEAT -WELDED LAP <br />WOOO MAILER. 5/4- (31.8 mm) x 4"(102 mm) MIN. <br />SECURED TO DECK <br />8- (203 m.) WIDE EVERGUARDO FLASHING STRIP <br />HEAT -WELDED <br />HEAT -WELDED LAP <br />CUT EDGE OR FLEXSEAL <br />*0 RXE <br />.Re. ... Mas REINFORCED EVERGUAR& MEMBRANE <br />a P i (PERIMETER SHEET IF REQUIRED) <br />WSH <br />' <br />12 ...... <br />FOR ALTERNATE TAPERED ROOF <br />EDGE. USE ENERGYGUARCr <br />.... ............... TAPERED INSULATION <br />....................... <br />ENERGYGUARD' ROOF INSULATION <br />ROOF OECKISUBSTRATE <br />FN0TF_j <br />1. FOR INSULATION THICKNESS GREATER THAN Ir (203 mm). A HARD BOARD 13 REQUIRED ON <br />MECHANICALLY FASTENED SYSTEMS ONLY <br />2.25-YEAR GUARANTEES AND ABOVE MUST USE EXTREME ACCESSORIES. <br />3, APPLY EVERGUARD41 TPO CUT EDGE SEALANT TO ALL CUT REINFORCED TPO EDGES <br />(REFER TO EVERGUARD" DETAIL 115). <br />P�- <br />COATED METAL ROOF EDGE DETAIL <br />EVERGUARDIII <br />N.T.S._ <br />77. <br />11.21-J19 202A <br />REFERENCE EVERGUARDO 300 SERIES <br />PARAPET WALL A CURB FLASHING DETAILS <br />FOR WALL TERMINATION <br />TYPICAL EVERGUAR&PERIMETER RW <br />SHEETS <br />C C <br />P_TT_bWd_b <br />Er ir-d-W-b _m 'W Tr 1r, IT <br />10 <br />IQ <br />6 <br />IQ <br />IQ <br />10 <br />It <br />It <br />it <br />1* <br />IQ <br />6 <br />6 <br />01 <br />CI <br />*1 <br />1 <br />I <br />Q <br />9 <br />IQ <br />Ia <br />it <br />0 <br />I <br />14 <br />10 <br />- - - - 0 <br />01 <br />01 <br />I <br />1 <br />10 <br />I* <br />1 <br />10 <br />10 <br />01 <br />0 <br />1 <br />IQ <br />0 <br />I <br />1 <br />10 <br />0 <br />01 <br />1 <br />10 <br />IQ <br />IQ <br />1 <br />1 <br />10 <br />IQ <br />01 <br />Cl <br />1 <br />1 <br />I <br />Ic <br />0 <br />1 <br />0 <br />IQ <br />0 <br />IQ <br />r <br />01 <br />1 <br />IQ <br />6 <br />0 <br />oil <br />IQ <br />IQ <br />1 <br />01 <br />1 <br />00 <br />10 <br />1- <br />10 <br />'.'I <br />1 <br />I 10 <br />11 <br />IQ <br />I <br />Cc <br />g- <br />ALTERNATE <br />HEAT -WELDED SEAMS <br />DRILL.TEd'PLATES & SCREWS <br />REFERENCE EVERGUARe200 SERIES ROOF <br />EDGE FLASHING DETAILS FOR EDGE <br />NOTE: TERMINATION <br />1. SEE EVERGUARDW MECHANICALLY ATTACHED SYSTEM GUIDELINES TO DETERMINE FASTENER SPACING <br />FOR VARIOUS DECK TYPES AND WIND UPLIFT REQUIREMENTS. AND FOR REQUIRED WAWR OF PERIMETER I <br />HALF SHEETS. MECHANICALLY <br />2. FOR INSULATION THICKNESS GREATER THAN 0* (203 mm). A COVER 130ARD IS ATTACHED SYSTEMS <br />REQUIRED ON MECHANICALLY ATTACHED SYSTEMS ONLY. I <br />ROOF MEMBRANE LAYOUT DETAIL <br />EVERGUARDIII 101A <br />W_ ITS. 11-21-191 <br />-'* <br />2 *N <br />ROOF DETAIL <br />ri � <br />ROOF DETAIL <br />.1.2) <br />NOT TO SCALE <br />\a41.2/ <br />NOT TO SCALE <br />rRevisions Date By <br />Mark A. jonnatti <br />Florida AR 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Highway hway 19 N <br />Clearwater, Erida 33765 <br />(727) 725-ARCH <br />(727) 725-2603fx <br />www.jarch.com <br />info@jarch.com <br />® jonnatti Architecture <br />Incorporated 2021 <br />ZEPHR <br />RETAIL <br />DEVELOPMENT <br />US HWY 301 <br />GALL BLVD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />ROOF PLAN <br />& DETAILS <br />(Drawn <br />MAI <br />Check <br />MAI <br />Date <br />AUG 18,2021 <br />Scale <br />AS NOTED <br />Job No <br />I ZEPHR RB <br />13 J <br />Sheet <br />
The URL can be used to link to this page
Your browser does not support the video tag.