I <br />DRIVEN <br />THRU a <br />••---- INDICATES EXTENT OF SECURITY MESH <br />SECURITY WALL NOTES: <br />I. SECURITY MESH SHALL BE SUPPLIED BY ALABAMA METALS INDUSTRIES <br />CORP (AMICO) (800) 366-2642 OR EQUAL AS APPROVED BY TRULIEVE <br />2. PROVIDE EXPANDED METAL MESH SYSTEM ASM 1.5-9F (MEDIUM SECURITY) <br />WITH SECURA CLIPS <br />3. INSTALL MESH SYSTEM IN ACCORDANCE WITH THE MANUFACTURER'S <br />PRINTED SPECIFICATIONS <br />4. MESH SHALL EXTEND FROM THE FLOOR TO THE UNDERSIDE OF THE <br />ROOF DECK.EXTEND METAL FRAMING TO THE ROOF DECK AND AS <br />NECESSARY ABOVE THE CEILING ELEVATION. GYPSUM BOARD FINISHES <br />ARE NOT REQUIRED ABOVE THE CEILING <br />5. ALL METAL STUDS USED FOR FRAMING SHALL BE A MINIMUM OF 20 <br />GAUGE MATERIAL <br />INVENTORY SIDE OF WALL <br />SECURITY MESH BY ALABAMA METAL INDUSTRIES SYSTEM <br />EXFASTENEDETOLMETALI STUDS WITH SECURAITCLIPSSPER <br />MANUFACTURER'S RECOMENDATIONS <br />, <br />F1 <br />�'/2" GYPSUM WALLBOARD OVER MESH <br />1--4" BATT ACOUSTICAL INSULATION <br />3 5/8"20 GA METAL STUDS AT 24"ON CENTER <br />WITH METAL STUD TOP AND BOTTOM TRACK <br />NEW SECURITY MESH <br />INTERIOR WALL <br />SCALE 11/2" = 1'-0" <br />FLOOR PLAN KEYNOTES <br />O SEE SHEET A3.1 FOR CABINET DETAILS <br />O2 NEW ADA TOILET ROOM - ROOM SHALL MEET <br />ALL ADA REQUIREMENTS AS SHOWN ON GI.2 <br />OINSTALL NEW METAL FURRING, INSULATION AND <br />1/2' GYPSUM BOARD ON ALL EXPOSED MASONRY <br />EXTERIOR WALLS PER DETAIL 5/A2.1 <br />4O NEW ELECTRIC HI -LOW WATER COOLER <br />OHEADER ABOVE BOTTOM AT 7'-2" AFF <br />WITH GYP BD CEILING <br />06 MILLWORK SUPPLIED AND INSTALLED BY OWNER <br />O7'-2" H NATURAL ANNODIZED STOREFRONT SYSTEM <br />WITH OBSCURE GLASS GLAZING. VERTICAL MULLIONS <br />AS SHOWN <br />,3 EXISTING WALL TO REMAIN <br />9O ELECTRIC HAND DRYER <br />PROVIDE TRANSLUCENT "TRULIEVE" FILM OVER <br />10 INTERIOR OF EXISTING STOREFRONT WINDOW <br />O11 PROVIDE 4" OF BATT SOUND INSULATION ABOVE <br />THE LAY -IN CEILING TYPICAL IN THE LOBBY/WAITING <br />AREA <br />WALL LEGEND <br />® EXISTING MASONRY WALL INSULATE IF EXPOSED AND PROVIDE 112" <br />q INTERIOR GYPSUM BOARD WALL FINISH PER DETAIL 5/A2.1 <br />3 5/8" METAL STUDS WITH 1/2' GYPSUM BOARD EACH SIDE <br />{B� ® SEE DETAILS I/A2.1, 2/A2.1. CONFORM TO METAL STUD SPAN <br />TABLES DETAIL 4/A2.1 <br />C 6" METAL STUDS PLUMBING WALL WITH 1/2' GYPSUM BOARD EACH SIDE <br />® MR GYPSUM BOARD ON WET SIDE. CONFORM TO METAL STUD SPAN <br />TABLES DETAIL 4/A2.1 <br />EXISTING 2-HOUR TENANT SEPARATION PARTITION <br />ENERGY CODE NOTES <br />FLORIDA BUILDING CODE - ENERGY CONSERVATION REQUIREMENTS <br />I. WITHIN 30 DAYS AFTER THE DATE OF PROJECT COMPLETION AND SYSTEM ACCEPTANCE, <br />RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING <br />OWNER. <br />2. PRIOR TO PASSING FINAL INSPECTION, THE REGISTERED DESIGN PROFESSIONAL SHALL <br />PROVIDE EVIDENCE THAT THE LIGHTING CONTROL SYSTEMS HAVE BEEN TESTED TO <br />ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, <br />PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE <br />CONSTRUCTION DOCUMENTS AND MANUFACTURERS INSTRUCTIONS. <br />3. AS REQUIRED BY FLORIDA BUILDING CODE - ENERGY CONSERVATION STATING: AN <br />OPERATING MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDING OWNER <br />UPON PROJECT COMPLETION <br />FLOOR PLAN <br />SCALE 1 /4" = 1'-0" <br />FLOOR PLAN NOTES: <br />I. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON ALL DRAWINGS AND NOTIFY ARCHITECT IF <br />DISCREPANCIES EXIST PRIOR TO COMMENCING CONSTRUCTION <br />2. CONFORM TO ALL APPLICABLE CODES LISTED ON SHEET GI.I <br />3. ALL LOW VOLTAGE ELECTRICAL WORK WILL BE UNDER A SEPARATE PERMIT <br />4. INSTALL NEW FLOOR FINISHES PER OWNER'S SELECTIONS, PATCH AND REPAINT ALL WALLS <br />AND CEILINGS INDICATED TO BE RE -USED. <br />5. ENTIRE BUILDING EXTERIOR AT TENANT SPACE SHALL BE CLEANED AND REPAIRED AS NECESSARY. <br />REPAINT ALL EXTERIOR SURFACES (2 COATS MIN), COLORS AS SELECTED BY TRULIEVE. <br />6. ADDRESS NUMBERS SHALL BE POSTED ON THE STRUCTURE. NUMBERS SHALL BE A MINIMUM OF 3" <br />IN HEIGHT AND SHALL BE POSTED DIRECTLY ABOVE OR TO THE SIDE OF ALL EXTERIOR DOORS. <br />4LL <br />(Revisions Date By <br />Mark A. Jonnatti <br />Florida AR 0010778 <br />JONNATTI <br />ARCHITECTURE <br />INCORPORATED <br />21021 US Highway 19 N <br />Clearwater, florida 33765 <br />(727) 725-ARCH <br />(727) 725-2603 fx <br />www.jarch.com <br />info@jarch.com <br />© Jonnatti Architecture <br />Incorporated 2021 <br />wrmr <br />9/6 /21 <br />T r u I i te v te% <br />INTERIOR <br />REMODEL <br />US HWY 301 <br />GALL BLVD <br />ZEPHYRHILLS <br />FLORIDA <br />33542 <br />FLOORPLAN <br />(Dra7wnMAJ <br />Check <br />MAJ <br />Date <br />AUG 31, 2021 <br />Scale <br />AS NOTED <br />Job No <br />TRULIEVE-ZH <br />Sheet: <br />Alel <br />