My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6611 Paden Wheel St (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6611 Paden Wheel St (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:20:27 PM
Creation date
2/19/2025 1:04:21 PM
Metadata
Fields
Template:
Building Plans
Street #
6611
Location
Paden Wheel St
Contractor
Lennar Homes LLC
Building Plans - Permit #
18230
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />WEATHER <br />BARRIER <br />RESISTIVE <br />HEAD FLASHING TIE <br />-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />S <br />DO NO- <br />BOTTO <br />F1 A Nr-'l <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />Scale: NTS <br />''n WEATHER <br />/E BARRIER & <br />�ARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHING <br />BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING <br />E <br />NM <br />8 <br />kSHING <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-l" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBIFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />3/4"-l" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED <br />THRESHOLD OF DOOR AN <br />UP JAMB 6". USE LIQUID N <br />OR EQUAL WEATHER PRC <br />SECTION -A (SEE DETAIL WP( <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />STALL SELF -ADHERED <br />-ASHING JAMB & HEAD <br />ASHING, SEE <br />-ANGED WINDOW <br />EE DETAIL WP01) <br />--LF-ADHERED FLASHING, <br />(TEND A MINIMUM 6" <br />ERTICALLY FROM <br />)TTOM OF <br />iRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />S <br />0 0, <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0. 6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />. , _` - I.--.1....'�. <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF <br />NEEDED IN CORNERS <br />THROUGH SELF -ADHERED <br />FLASHING <br />RUBBERIZED ASPHALT <br />RUBBERIZED ADHESIVE <br />ASPHALT ADHESIVE <br />SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />FOUNDATION WEEP SCREED <br />DECK JOIST ET Me OUTSIDE CORNER UIT M11 400 <br />SCORED <br />RELEASE PP PER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />5Q <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R7 03.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more ofthe <br />following or other approved method: <br />1. 1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FIVIA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.01 9-Inch (No. 26 Galv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2 <br />Detail Instructions <br />Refer to the number marked as n each detail that corresponds to the numbered items in the list of <br />(Di <br />instructions below: <br />1 . Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (16" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />...... .... <br />.. .... <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />oe <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />NOT USED NOT USED NOT USED SCALE: NOT TO SCALE <br />pigs <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTIVIC 1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />-Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />ce) <br />W <br />< <br />V) 0 <br />Q) U-"> <br />(D <br />4--d LU <br />M 0 <br />0 <br />v <br />V) <br />E <br />0 <br />Cn <br />In, <br />LU <br />E <br />0 C, <br />0) co <br />C M M <br />T :2 CO <br />C\1 <br />43 <br />0 C) <br />LL CO <br />5 -00 <br />C) cn <br />a) <br />5. <br />0 2 i:�- <br />(0 0. C, <br />< 0 <br />L. O:s <br />.e CL <br />A I <br />B <br />R <br />C" <br />0 <br />C1> <br />LO <br />- <br />co, Y, C,4 <br />U) C� CJ <br />U., <br />. I— <br />d <br />0 <br />ul Co Z <br />:3 G Co r <br />14W 41Y I- In r, r� o <br />U_ U_ <br />Cq <br />43 co <br />LLI _J <br />LU LU <br />W <br />0. '20 <br />Z 0 = <br />0 < <br />IL <br />= M <br />rn <br />Z <br />W 0 04 <br />0 `2 <br />M <br />6 Cal <br />0 E] <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seat. <br />c) <br />C) <br />Z <br />0 <br />14 4-J C) <br />V) 1:5 �.D '.., <br />> V) ro <br />. M <br />Z <br />4-1 <br />< Ln M Ln <br />d- Ln <br />2: (A 0 <br />CU - Ln <br />L_ LL <br />Z <br />CL <br />Ce U>- <br />CL 00 <br />< <br />Z E <br />W <br />Z <br />LU <br />_J C:) <br />110 <br />0 <br />0� Ce Z <br />LU U_ <br />LU Z Ln <br />M Z Z <br />U 8 LAU 0 0 <br />Z < 0 <br />9 Z Z 0. Q� <br />0 U <br />Z >7 < 2: <br />Z < <br />Z <br />Z <br />U Z 0 W <br />� :5 LEE _J <br />i <br />0 <br />08 4 C) <br />fy) <br />ica� <br />0 Z) LU <br />2 <br />a. 0 Z @ <br />LU = Z <br />LU <br />C:) <br />Ln <br />0 <br />r_J <br />_J <br />un <br />< <br />LU <br />C) <br />U1 0 <br />LU W < <br />!�;� <br />0 <br />< <br />00 Z <br />Z g 0 <br />LU 0 0 U <br />U Lou <br />F_ -_Ojo� 2 <br />rs <br />-0 <br />M <br />Z <br />Z <br />9,,..0 <br />LL <br />LEI F_ <br />zzxoz <br />CY-- Z <br />a 0 ::1 0 <br />Z0 <br />UJ <br />rN 0 <br />ULU <br />< U r- <br />- V 6 <br />> <br />_J <br />r44 0 <br />8H82 <br />LL <br />C) <br />�� LU 0 LJ_ Z <br />< 2: 0 <br />0 <br />ro <br />Ln <br />2 <br />(Y 2: LL 0 <br />Ln Z < <br />0 <br />LLJ <br />_J LU <br />_J UZJ <br />< X <br />9 <br />C:) <br />LL <br />LL <br />LU <br />Z <br />> <br />0 <br />SCALE AS NOTED <br />PLOT DATE: 12/7/2012 <br />TECH: FFLORES' <br />VERSION NO. <br />5,11 <br />JOB NO: 16-6654 <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.