Laserfiche WebLink
r <br />i <br />i <br />J <br />T <br />I <br />1 <br />I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />00 #14 t0 lights & outlets <br />NEMA 1 01 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 01 #10to WH <br />00 #8 to Range <br />00 #6 to HVAC <br />METER <br />MAIN T —1 <br />50=2/0 <br />200=4/0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />M 4 Bare Cu Ground <br />INTERSYSTE <br />BONDING r—] #4 GROUNDING WIRE <br />TERMINATION PER - — WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: to AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />3" <br />C) <br />1.5" VTR -III <br />I <br />I <br />I <br />I r. <br />I I I 1 <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET— <br />r=====1 <br />I( II <br />II ALT II <br />AC PAD <br />It 11 <br />L=====J <br />WP <br />GFI'4 <br />DISC. <br />oC =_ <br />I-- <br />w3' <br />U_ O 0 <br />EE <br />> LU <br />O m <br />O <br />WALL MOUNTED LIGHT FIXTURE <br />t t U KUU lvl L <br />I I I <br />LlCati I A5 <br />I 1 1 <br />- <br />o <br />PER SPECS <br />O <br />RECESSED LIGHT FIXTURE <br />PLUMBING <br />RISER <br />I I <br />I I <br />- <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />I ------------- <br />TRACK LIGHT <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />I <br />I <br />- <br />- <br />GARAGE DOOR <br />FLUORESCENT LIGHT FIXTURE <br />BE VERIFIED WITH PLUMBER <br />I <br />I - <br />GFI <br />EXHAUSTFAN <br />I <br />I <br />or------------ <br />I to <br />I <br />----- <br />GARAGE <br />— <br />- <br />EXHAUST FAN/LIGHT <br />SWITCH FOR DISPOSAL 1 <br />I <br />I <br />COMBINATION <br />I <br />Q <br />rQj <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />i <br />11RRIGATION <br />IGFI @ 44" <br />°' <br />CH <br />CHIMES (OPTIONAL) <br />I <br />A.F.F. <br />P13 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />— — — —GF1- — <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />I <br />I <br />I <br />I <br />1 <br />-- <br />SD <br />SMOKE DETECTOR <br />-- <br />I <br />I <br />0 <br />I <br />-GF1 <br />I <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />GFII <br />■ <br />-------------------- <br />COACH LIGHTS <br />I <br />IG[ANGE <br />a <br />TELEPHONE (OPTIONAL) <br />- <br />i <br />2 X 4 FL. <br />i <br />OR PREWIRE AS <br />PER SPECS <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />GFI <br />� <br />TV <br />TELEVISION (OPTIONAL) <br />__ <br />KITC H RN <br />I <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />-- <br />I <br />i <br />IDEDICATED <br />THERMOSTAT11 <br />I I <br />:- <br />I <br />I <br />IECEPTACLE <br />IMICROWAVE <br />IM <br />ELECTRIC METER <br />I I <br />- <br />�,IG <br />-_-_! <br />HOOD <br />PER SPECS <br />op"I <br />ELECTRIC PANEL <br />=_- JI <br />/ I <br />—>� <br />DISCONNECT SWITCH <br />G <br />ROUGH -IN FOR OPT. CEILING FAN <br />�J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />G—e <br />(1) PHONE LINE, (1) DATA PORT <br />OPTIONAL LIGHTING <br />SCALE: %4'=1'-0" <br />ELECTRICAL PLANS <br />SCALE: %4'=1'-0" <br />C3 <br />> <br />-= <br />a� o <br />cc U N <br />'�f <br />a CO x <br />�LL-a <br />H cc C <br />to -a.CV .0 <br />y w 0 cc <br />Q <br />,✓, 6i <br />a E s c <br />m G, Q <br />as <br />i '2P C �i <br /><O <br />.= <br />N E <br />C <br />CO <br />p <br />tw <br />0 <br />M <br />N <br />0 <br />N <br />M <br />C=> <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W <br />v £ o <br />0 o$"� <br />g <br />cli <br />0 <br />C?N � <br />N <br />W <br />� r- r'— w <br />a <br />Q <br />�mv w°_Sf <br />a <br />toLLi� W z <br />0 <br />oo <br />Z <br />w .� <br />� �tE N t0 on J Q <br />m <br />U) °' °' <br />W <br />Z <br />LLW <br />o Zr Ci w <br />N M Z U G <br />Z <br />H <br />o� ❑❑❑ <br />W <br />Z N M <br />o g <br />z o � <br />co <br />(DV) <br />4-LL <br />co - <br />W � <br />� <br />�u <br />O,1,o <br />N <br />c w <br />v) <br />U <br />oilW <br />_ E <br />U o N <br />m � <br />�® <br />� <br />¢ " 0 <br />N <br />o <br />J� <br />w <br />M <br />< <br />r._ <br />(6 <br />Zo <br />O <br />> m <br />¢ o- <br />Q <br />o <br />w= <br />? <br />F— 6 <br />20 <br />o<°w <br />00 <br />Z <br />Z <br />CD fu <br />r0 <br />L <br />a s <br />¢z <br />¢ <br />ii <br />wz <br />K <br />_ <br />C/J C <br /><' <br />�S < <br />mo <br />~O `r <br />Z <br />m j <br />Wo <br /><� <br />¢z <br />�Z <br />8 <br />oz <br />o <br />go <br />-Z <br />W <br />p <br />M <br />LL <br />< <br />�o <br />nw <br />_ <br />°Z <br />=3 <br />o <br />z <br />wa <br />�F <br />;o <br />M <br />v <br />zl �a <br />a � <br />° 3 <br />0 <br />>� <br />Orn <br />Nt <br />E <br />m <br />CID L0 <br />�-. <br />Q <br />N <br />U <br />o <br />0 <br />N <br />!!^� <br />vJ m <br />CN <br />}+ <br />O <br />LL <br />L <br />Ncco <br />m (`'N <br />d) <br />L.n <br />O <br />In <br />�-- <br />Q <br />0) N <br />r <br />m <br />T <br />CD CY) <br />o <br />M <br />fp <br />Z <br />Z <br />c <br />E <br />E <br />hi <br />c <br />m <br />a <br />c0 0 <br />Q o <br />c <br />JOB <br />NO: <br />23-06117 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />