My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6754-6780 Basswood Cir
Zephyrhills
>
Building Department
>
Building Plans
>
6754-6780 Basswood Cir
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:49:53 PM
Creation date
2/19/2025 1:05:29 PM
Metadata
Fields
Template:
Building Plans
Street #
6754-6780
Location
Basswood Cir
Contractor
Ryman Construction
Building Plans - Permit #
19005-19010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTE: METERS M, <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1, ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE; 12' AFF (GENERAL) <br />KITCHEN 44' AFF <br />BATHROOM 39' AFF <br />LAUNDRY ROOM 36' AFF <br />EXTERI❑R WATERPROOF 12' AFF <br />GARAGE GENERAL PURPOSE 42'` AFF <br />RANGE 2' AFF <br />2, ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE P❑SSIBLE <br />3. ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF. <br />4, ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATI❑NAL ELECTRIC CODE, LATEST <br />EDITI❑N, BY LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESP❑NSIBLE <br />FOR THE INSTALLATI❑N & SIZING OF ALL ELECTRICAL, WIRING & ACCESS❑RIES. <br />5, ALL SMOKE DETECTORS SHALL BE HARDWIRED INT❑ AN ELECTRICAL POWER SOURCE <br />AND SHALL BE EQUIPPED WITH A M❑NITORED BATTERY BACKUP, <br />INSTALL SMOKE DETECTOR/CARBON M❑N❑XIDE ALARMS PER FBC R313, <br />6, ALL CIRCUITS ARE REQUIRED TO BE EITHER ARC FAULT OR GROUND FAULT <br />PROTECTED PER NEC 2008 210.12 (B) <br />7, ALL RECEPTACLES ARE TO BE CHILD PROTECTED PER NEC 2008 406.11 <br />8, GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N,E,C, 2008 <br />9, R313.2 1 CARBON M❑N❑XIDE PR❑TECTI❑N, CARBON M❑N❑XIDE ALAMRS OR DETECTORS <br />SHALL BE INSTALLED IN ALL DWELLING UNITS IN ACCORDANCE WITH NFPA70, SUCF <br />DEVICES SHALL BE LISTED BY THE APPR❑PRIATE STANDARD, EITHER ANSI/UL 2034, <br />STANDARD FOR SINGLE AND MULTIPLE STATI❑N CO ALARMS OR UL 2075, GAS <br />AND V APR❑ DETECTOR SENSOR, ACC❑RDING TO THE INSTALLATI❑N. <br />10 , 313,22 3 C❑MBINATI❑N ALARMS; C❑MBINATI❑N SMOKE/CARBON M❑N❑XIDE ALARMS <br />SHALL BE PERMITTED IF EACH MEETS THE APPLICATION UL STANDARD, <br />11, KEEP ALL SMOKE DETECTORS MINIMUM OF 36' FROM BATHROOM DOORS. <br />12. IN NEW C❑NSTRUCTI❑N, SMOKE DETECTORS SHALL BE HARDWIRED INT❑ THE A/C <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A M❑NIT❑RED BATTERY <br />BACKUP. <br />13. BATHROOM EXHAUST FANS MUST VENT TO THE EXTERI❑R OF THE BUILDING, <br />VENTILATION TO ATTIC SPACE AND SOFFITS IS NOT ACCEPTABLE, <br />14. ALL DOORS AND WINDOWS PR❑VIDING DIRECT ACCESS FROM THE HOME TO THE <br />POOL SHALL BE EQUIPPED WITH A EXIT ALARM COMPLYING WITH UL 2017 THAT <br />HAS A MINIMUM SOUND PRESSURE RATING OF 85 DBA AT 10 FEET, AND EITHER <br />HARDWIRED OR OF THE PLUG-IN TYPE. THE EXIT ALARM SHALL PRODUCE A <br />C❑NTINU❑US AUDIBLE WARNING WHEN THE DOOR OR WIND❑W ARE OPENED, <br />15, ADD GFCI PR❑TECTI❑N TO RECEPTABLES IN LAUNDRY ROOMS AND UTILITY ROOMS <br />OF DWELLINGS WHERE INSTALLED WITHIN 6' IF THE ❑UTSIDE EDGE OF A SINK, <br />THIS WOULD INCLUDE THE RECPETACLE INSTALLED FOR A WASHING MACHINE, <br />RECEPTABLES OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A <br />RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24, <br />THE WIDTH OF A SINK OR RANGE IS NOT TO BE INCLUDED IN THE SPACING OF ALL <br />OUTLETS UNLESS THE DISTANCE FROM THE SINK OR RANGE IS GREATER THAN 12' <br />FOR STRAIGHT COUNTER TOPS AND 18' FOR SINKS AND RANGES INSTALLED IN <br />CORNER COUNTERS. <br />SYMBOL <br />DESCRIPTION <br />SWITCH <br />$3 <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />8 <br />110 V RECEPTICLE(1/2 SWITCHED) <br />6 <br />110 V RECEPTICLE <br />&FI <br />110 V RECEPTICLE - GROUND FAULT <br />8AFI <br />110 V RECEPTICLE - ARC FAULT <br />8wP <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />220 V RECEPTICLE <br />[] <br />DUPLEX OUTLET IN FLOOR <br />110 V QUAD <br />lbwP <br />110 V QUAD WATERPROOF OUTLET <br />® <br />RECESSED INCANDESCENT <br />`? <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT C❑MBINATI❑N <br />FL❑URESCENT FIXTURE <br />dD <br />FLOOD LAMPS <br />VANTITY LIGHT <br />cp <br />PUSH BUTTON FOR GARAGE OPENER <br />S&D - <br />SM❑KE. /FIRE DETECTOR/ALARM <br />car, <br />SMOKE/CARBON M❑N❑XIDE DETECTOR - COMBO <br />CARBON M❑N❑XIDE DETECTOR <br />II <br />CEILING FAN ONLY <br />J <br />G-, ( i , <br />� 3 <br />CEILING FAN /LIGHT <br />LJ <br />FAN W/L <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />NOTE <br />R314 <br />PLANS SHALL COMPLY TO R314 SMOKE ALARMS <br />R315 <br />PLANS SHALL COMPLY TO R315 CARBON M❑N❑XIDE ALARMS <br />
The URL can be used to link to this page
Your browser does not support the video tag.