r <br />J <br />a <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />UNDERGROUND IDIS <br />SERVICE BY POWER CO.� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />150A/200A INDOOR <br />PANEL CENTER <br />0 to lights & outlets <br />2 to appliances and GFI <br />)to WH <br />to Range <br />to HVAC <br />200=4/0 in 2" Conduit <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall he responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEG 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />S. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (AEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single: and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarris shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C Bit- ctrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilafon to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of d Nellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacirg of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 13" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />III_ 1.5" VTR <br />'I <br />I <br />I <br />I <br />� I <br />� I <br /><\ I I <br />I I <br />I I I I <br />I_o <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />PLUMBING RISER- <br />FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACKLIGHT <br />LIGHT <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUST FAN <br />SWITCH FOR DISPOSAL <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />— — — — -GFI— — — — <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />r--- <br />I <br />I <br />o <br />O <br />a <br />I <br />L G I <br />SD <br />SMOKE DETECTOR <br />— — — <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />IGFI <br />GFII <br />I <br />TELEPHONE (OPTIONAL) <br />i <br />I <br />2 X 4 FL. <br />i <br />- <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />I <br />IGFI <br />© <br />TELEVISION (OPTIONAL) <br />K TC H E N <br />02 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (i)@ 1 A.F.F. <br />DEDICATED <br />1 <br />I <br />- <br />RECEPTACLE <br />f <br />O <br />THERMOSTAT <br />FOR MICROWAVE <br />I <br />I <br />I <br />I <br />p]M <br />ELECTRIC METER <br />RANGE HOOD <br />PER SPECS <br />GFII <br />- <br />I I <br />own <br />ELECTRIC PANEL <br />I <br />I 3 <br />L=== <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUG H-IN FOR <br />J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />OPTIONAL LIGHTING <br />SCALE: Y4'=1'-0" <br />V Ii y <br />S.D <br />I I j `♦ <br />I I � <br />�♦ <br />ROUGH -IN FOR <br />I I ��!%� OPT. CLG. FAN/ <br />I I I G LIGHT PRE -WIRE <br />BEDROOM 2 ' <br />I I I <br />I I I <br />I I I <br />I I <br />L-----------I <br />I IA ER <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />( I <br />I I <br />L---------------------------------------J <br />PER SPECS <br />ELECTRICAL PLANS <br />SCALE: Y4'=1'-0" <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET <br />r_===_i <br />ALT " <br />AC PAD I I <br />Il 11 <br />WP <br />)GFI <br />DISC. <br />c_ <br />WZ <br />BEr <br />OO <br />cr0� <br />>_5m <br />ers <br />N <br />C9 <br />N <br />N o <br />d� <br />DC c <br />> W <br />o� t= <br />a� o <br />C 10 L 1 (V <br />— m <br />x <br />y c LL a <br />N O C <br />N <br />d <br />4 ev Y <br />a s CD <br />d <br />> o s c <br />� 3 <br />c� a3 <br />9 rY •� T <br />H as <br />c E <br />a� <br />a <br />M <br />N <br />0 <br />N <br />co <br />LEI, <br />Eiy <br />e <br />`ems Off'.\ 'E'NS•4��ice' o <br />�) � �••• <br />c, •� <br />No PE78750 m <br />w <br />:.U,• <br />�1 yJy. <br />NA <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />E $ N <br />8 ie <br />r <br />V N O' <br />O J <br />LL <br />�cNSc� <br />LL a u' <br />ii <br />Jett <br />Z <br />Z <br />132 <br />t to C <br />'NNco m w <br />W m <br />ogl00 ;o d <br />W in T O3 Z <br />N MZ Q � <br />LL <br />3 <br />Z OU ❑❑❑ <br />W <br />CD <br />z <br />Z <br />a <br />z p Q <br />¢ R <br />a <br />N <br />�/ r <br />� V C <br />GA <br />w m <br />A N <br />Q A <br />N <br />U <br />Ow <br />f2--_41 <br />t <br />I <br />c U) <br />¢ � <br />�Q <br />o <br />Z <br />0ao <br />E <br />Z0 <br />w° <br />>� <br />_® <br />EE O <br />V <br />i <br />❑a <br />F� C <br />ao <br />�o <br />o <br />Z <br />gE <br />CO '� <br />0 <br />ao <br />O % <br />ww <br />a <br />a� <br />C <br />¢o <br />m� <br />0 Z <br />Z <br />Z< <br />m J <br />w`i3 <br /><� <br /><w <br />�Z <br />8 <br />g <br />Zo <br />az <br />W <br />�• � <br />a� <br />UJ W <br />_t <br />C <br />F <br />M <br />w� <br />L° <br />0 <br />I �dT0 <br />. <br />z <br />3: <br />O <br />0 <br />i <br />m� <br />>L6 <br />Orn <br />m <br />m <br />c� <br />0 <br />CL <br />N <br />� <br />�1 <br />1.L <br />o <br />m <br />N <br />o <br />LO <br />LL <br />04 <br />M° N <br />0) <br />L <br />CD N <br />L>n <br />r <br />Q OO <br />T <br />C`/�, CAD �C j <br />o <br />Z <br />W <br />Z <br />N <br />E O <br />a <br />E v u; <br />0 _j c o <br />c <br />JOB <br />NO: 23-02469 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />