My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (117)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (117)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:08:17 PM
Creation date
2/19/2025 1:08:09 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Interior Enterprises
Building Plans - Permit #
3084
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br />MAXIMUM AT CJAE GROUP <br />8'-0" BACKING PARTITION GENERAL NOTES: <br />MAXIMUM PLATE ARCHITECTURE <br />1. P-TYPES ARE APPLICABLE TO INTERIOR PARTITIONS ONLY, SEE WALL SECTIONS FOR <br />STRUCTURE EXTERIOR WALL CONDITIONS AND TYPES. <br />TOP TACK 2. FOR CEILING HEIGHT, SEE REFLECTED CEILING PLANS. 106 WEST NORTH BAY STREET t TAMPA, FI.33603 <br />http://cjaegroup.com <br />—PROVIDE C.J. ABOVE PROVIDE 3 5/8" X 20 GA. 3. USE SPECIALTY GYPSUM BOARD FULL EXTENT OF PARTITION WHERE WALL OR FLOOR <br />-- -- STUDS DOORS 3'-6" AND WIDER DIAL. BRACE AT ALL MOUNTED PLUMBING FIXTURES (WET WALLS) ARE INDICATED AND OTHER THAN TILE <br />A SEE 5/A.90 DOUBLE STUDS (MINIMUM FINISH IS SCHEDULED. <br />SEALANT : 2 £ACH DOUBLE STUD) C3aL <br />WITHIN /7.�. BRACING OVER DOOR OPENINGS - 4. USE TILE BACKER BOARD PANELS AT PARTITIONS WHERE TILE FINISH IS SCHEDULED. <br />ANNULUS ,:..:, BOTTOM OF ROOF METAL RUNNER TACK 16 GA. DOUBLE STUDS <br /><1( <br />,. OR FLOOR ASSEMBLY <br />>� c� 5. PROVIDE ACOUSTIC SEALANT EACH SIDE OF PARTITION AT HEAD AND BASE AND AT <br />u METAL STUD FRAMING 16 GA. TRACK ALL PENETRATIONS EXPOSED OR CONCEALED. <br />,:.... ENGINEERING <br />AROUND CONCRETE SLAB <br />SEE STRUCT. METAL RUNNER @HEAD METAL STUDS @ 16 O.C. P-TYPE LETTER DESIGNATIONS: <br />z <br />< i <br />DRAWINGS FOR SIZE � `• � =• OF DOOR OR VIEW � <br />AND LOCATIONS WINDOW (USE DOUBLE <br />3 4" CONT. CHANNEL (NO SUFFIX) FULL HEIGHT, NON -INSULATED <br />w DOUBLE STUDS @CONTROL STUD HEADER AT DOORS / <br />JOINT LOCATIONS 3'-6" AND WIDER) BRACING @ MIDPOINT FINISHED CEILING SEE A FULL HEIGHT, INSULATED (WITH 3" SOUND ATTENUATION BLANKETS) <br />� ��� • � ' � R.C.P. FOR HEIGHT <br />METAL _ B 6" ABOVE HIGHEST ADJACENT CEILING, NON -INSULATED <br />PIPE OR ' 20 GA, DOUBLE STUDS STANDARD STUDS, REFER C 6" ABOVE HIGHEST ADJACENT CEILING; INSULATED <br />CONDUIT _ \ @ DOOR OR VIEW HORIZ. BRACING SUPPORT TO SPECIFICATIONS <br />A N WINDOW JAMBS (FULL FOR CASEWORK, HANDRAILS, <br />GWB WALL PROVIDE FIVE -SIDED HEIGHT) VERIFY REQUIREMEN EQUIPMENT. SEE FLR. PLANS S DESIGNATES SMOKE TIGHT CONSTRUCTION W/UL BW-S-0001. UL HW-D-0154 <br />SCALE: 3 =1 -0 ::. 5/8 GWB-2 BOX AROUND FROM DOOR/WINDOW MANUF. AND ELEVATIONS BACKING PLATE WHERE <br />RECESSED BOXES GREATER ADJACENT ELECT. OCCURS, SEE BACKING D 3'-0" ABOVE ADJACENT CEILING, INSULATED <br />THAN 16 SQ. 1N. (RATED BOXES IN RATED ;� PLATE DETAIL 9 10 A901 L LEAD -LINED 5/8" GYPSUM WALL BOARD. REFER TO PHYSICIST REPORT FOR <br />NOTE: -- - WALL -(MAX 100 SQ. 9,1o/A901 MAX. 16 SQ. IN. OPENING � / <br />WALLS ONLY) SEE DETAIL -�- �- IN GWB PER STUD SPACE LEAD SHIELDING REQUIREMENTS <br />rJ r INCHES IN 100 SF r-; <br />STUDS AS REQUIRED BY <br />1. 1 HOUR FIRE RATING -u_-u_ 1-J LJ OF WALL) a (RATED WALLS ONLY). BACKING PLATE <br />SECTION A -A 2. REFER TO UL DIRECTORY, FIRE ---_- <br />RESISTANCE (VOLUME 2) AND ��METAL RUNNER TRACK <br />MANUFACTURERS LITERATURE FIN. FLR. LINE FLOOR TRACK P1 <br />FOR COMPLETE DETAILING <br />(1) ONE LAYER GWB EACH <br />SIDE <br />)SOALE.Y3�R��O <br />NO WL1084 TYPICAL STUD FRAMING ELEVATIONS <br />2 SCALE: NTS P2 <br />3 5/8" MTL STUDS @ P1 TYPES <br />6" MTL STUDS @ P2 TYPES <br />(4) #10 S.M.S. <br />FLOOR ASSEMBLY 4 7/8» STAMPS AND APPROVALS <br />16 GA. TRACK (SEE STRUCTURAL DRAWINGS) <br />-- -- STUDS COPE & BEND <br />A TRACK CONTRACTOR'S 7 1/8" <br />CAULK CONTROL JOINT CONT. I , C <br />OPTION <br />WITHIN ABOVE DOOR 14 GA., 2X2 ANG co <br />ANNULUS HM DOOR FRAME <br />I TOP & BOTTOM, WITH �� <br />y " JAMB BELOW METAL STUD CRIPPLE (6) #10 S.MS. FIRE OR ACOUSTIC <br />C Mom'.. a`" ::•ah;a. ABOVE DOOR FAME <br />A SILL CONDITION J SEALANT BOTH SIDES <br />:.•§ � ATTACH METAL DEFLECTION77 <br />TRACK TO CONC SLAB GWB <br />Q <br />ANCHORS @ 4 C. <br />CEILING <br />MAX. -SEE 6/A903 <br />FOR ADDITIONAL INFORMATION <br />�r PARTITION -SEE FLOOR <br />PLANS FOR P-TYPE <br />PVC/CPVC ':�: ` '.`...:: PARTITION -SEE FLOOR SUBSTRATE <br />PLANS F P TYPE <br />PLASTID PIPE ..... ..: ....... ........ ......... :.. �.. _ .:.. � � <br />- - <br />:..: <. ' .: .. 16 GA STUDS <br />TRACK HTOEFLOOR SLAB <br />-- -- GWB WALL A <br />t z W/ ANCHORS @ 24" O.C. <br />MAX. 2 1/2" MTL STUDS @ P3 TYPES <br />SAFING INSULATION PACKED " <br />NOTE 20 GA. DOUBLE STUDS Co TIGHTLY CONT. FULL HEIGHT 3 5/8 MTL STUDS @ P4 TYPES <br />BOTH SIDES OF DOOR FIRE OR ACOUSTICAL <br />1. 1 AND 2 HOUR FIRE RATINGS JAMB (FULL HEIGHT) B HEAD CONDITION SEALANT FULL DEPTH OF VARIES, SEE PLAN <br />2. REFER TO UL DIRECTORY, FIRE FINISH FLOOR GWB, BOTH SIDES <br />SECTION A -A RESISTANCE (VOLUME 2) AND Q <br />MANUFACTURERS LITERATURE WHERE ONE SIDED PARTITIONS <br />N 0 S OCCUR BACK TO BACK PROVIDE <br />FOR COMPLETE DETAILING MTL STUD BRACING @ EACH STUD PAIR 48" O.C. VERTICALLY <br />UL SYSTEM NO WL2098 CONTROL JOINT 4 HEAD AND SILL FRAMING INSULATED PARTITION PARTITION <br />SCHEDULE <br />F SCALE: 3"=1'-O" (D5SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A <br />DULY LICENSED ARCHITECT UNDER THE LAWS OF THE STATE OF FLORIDA. <br />TO THE BEST OF MY KNOWLEDGE, THESE PLANS AND SPECIFICATIONS <br />COMPLY WITH THE APPLICABLE BUILDING CODES. <br />+ <br />CARLA J. HARVEY; LICENSE NO: AR95088 <br />- WINDOW HEAD%SILL <br />_, <br />1 LAMINATE <br />LEAD -LINED HOLLOW N SCRIBE i <br />METAL FRAME <br />IN -WALL <br />5/8" X 1 1 /8" PLASTIC LAMINATE SUPPORT <br />REMOVABLE STOP CABINETRY �, ° ° BLOCKING/ COL. <br />►r Ins o STRAPPING <br />Ld <br />B _ P-LAM SLOPED TOP ; ° <br />i SEALANT w ° ° <br />LEAD -LINED GLAZING <br />AND FRAME, PER SS-1 SOLID SURFACE <br />PHYSICIST REPORT + ADJ. PLASTIC <br />.LAMINATE SHELF COUNTERTOP W/ 4" + <br />+ SS-1 BACKSPLASH <br />0 <br />i PL-1 CASEWORK -1-' 7 <br />° ° N ' <br />ant mealth <br />Adummo <br />STUD TRACK N ° ° <br />>, ° ° I 12" INSIDE COUNTERTOP W/ FALSE 1'-5" 1'-9" 3'-0" <br />Zephyrhills <br />5f8 LEAD -LINED ° ° CLEAR BASE AT COLUMN <br />GWB ON METAL N ° ADJ SHELF ° ' <br />FRAMING 6'-4" PROJECT NAME <br />° FIELD VERIFY DIMS <br />ADVENTHEALTH ZEPHYRHILLS <br />° ROOM 6 X-RAY REPLACEMENT <br />SEWORK - UPPER CABINET SECTION X-RAY ROOM - CASEWORK ELEVATION@CA <br />SCALE: 1/4" = 1'-O" PROJECT LOCATION <br />1/16" LEAD —LINED EQUIVALENT WINDOW JAMB ' 7050 GALL BOULEVARD <br />GLAZING AND FAME, PER <br />PHYSICIST REPORT ZEPHYRHILLS, FL 33541 <br />5/8" X 1 1 /8" PROJECT NUMBER <br />REMOVABLE STOP ANCHORS, AS SEE PLUMBING FOR SINK ; ,�"�� 2021-009 <br />REQUIRED & FAUCET SPECS. <br />U.N.O. BACKSPLASH U.N.O. I i BACKSPLASH PROJECT PHASE <br />SS-1 SOLID SURFACE SS-1 SOLID SURFACE i + 100% CONSTRUCTION DOCUMENTS <br />w a. s�. _,- .,- , COUNTERTOP SEALANT COUNTERTOP SEALANT <br />z C° ° a .' ALL SPLASHES ALL SPLASHES ISSUE DATE <br />I� P-LAM CABINETRY " `- TO BE HARD PLAM CABINETRY TO BE HARD AUGUST 18, 2021 <br />-TYPE VA RIES ' SEAMED W/MFR - TYPE VARIES i i SEAMED W/MFR <br />SEE INT RIOR ° ° i RECOMMENDED SEE INTERIOR » + RECOMMENDED <br />ELEVA IONS ° ° PLAM CABINETRY ADHESIVE ELEVATIONS 1 -2 ADHESIVE REVISIONS LIST <br />AND SPECIFIC TION ° ° -TYPE VARIES AND SPECIFICATION <br />1/2" TYP " ° ° + SCHEDULED SEE INTERIOR + <br />SCHEDULED --------------'` SCHEDULED NO. DATE DESCRIPTION <br />2 30 2 ° ° PARTITION ELEVATIONS + PARTITION i PARTITION <br />° ° + IN -WALL AND SPECIFICATION IN -WALL IN -WALL <br />° ° SUPPORT SUPPORT SUPPORT <br />° ° BLOCKING/ Z BLOCKING/ Z + BLOCKING/ <br />A EQ. 2'-6" , FQ ° ° r STRAPPING o STRAPPING o STRAPPING <br />`_ ° ° w ~Q tol- <br />> w ° ° > w <br />° ° <br />o ° ADJ SHELF ° cuj n o ADJ SHELF ° � SLOPED P-LAM TOP <br />+ - - ° ° <br />+ <br />NEW LEAD -LINED o I SHEET TITLE <br />INTERIOR ELEVATIONS, <br />VIEW WINDOW AND FRAME. <br />`i INSTALL ABOVE CONTROL DESK <br />COUNTERTOP. ; <br />CASEWORK INTERIOR DETAILS <br />3'-7" , <br />4'-0" <br />ANGLED WALL <br />1'-6" 2'-0" 2'-0" SHEET NO. <br />X-RAY ROOM - VIEW WINDOW ELEVATION AND DETAILS tARDROBE CASEWORK SECTION CASEWORK- BASE CABINET SECTION CASEWORK -SINK CABINET ECTION PATIENT ST�1�3E CASEWORK ELEVATION <br />SCALE: 4= 1'-0"LE: 1 1/2" = 1'-0" @S6,[E./4" = 1'-0" SCALE: 1 1/2" = 1'-0" J SCALE: 1/4" = 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.