2 1 3 I 4 <br />FIRE PROTECTION SYMBOLS AND ABBREVIATIONS <br />NOTE: SYMBOLS AND ABBREVIATIONS INDICATED HERE AND NOT USED IN THE CONTRACT DOCUMENTS DO NOT APPLY <br />TO THIS PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED IN THE CONTRACT DOCUMENTS. <br />PIPE FITTINGS PIPE VALVES AND SPECIALTIES GENERAL SYMBOLS <br />D ELBOW DOWN SHUTOFF VALVE y FIRE DEPARTMENT CONNECTION <br />O ELBOW UP BUTTERFLY VALVE --Ci INSPECTOR'S TEST ASSEMBLY <br />., - TEE DOWN CHECK VALVE —Q-- INSPECTOR'S TEST AND DRAIN ASSEMBLY <br />n TEE UP mow— 0 S & Y VALVE SPRINKLER ZONE BOUNDARY <br />D PIPE CAP �' FLOW SWITCH HYDRAULIC CALCULATION <br />DESIGN AREA <br />PIPE HANGER <br />PIPING CONNECTION — — — — — DEMOLITION OF PIPING, DEVICE, ETC. <br />WYE STRAINER �� PRESSURE GAUGE <br />WITH DRAIN VALVE <br />— —I( BALL VALVE <br />PIPING SYSTEM LABELS <br />NEW EXISTING <br />F XF FIRE SUPPLY <br />— SPR— —XSPR — SPRINKLER PIPE <br />0 <br />n <br />REFERENCE SYMBOLS <br />8 NEW CONNECTION TO EXISTING <br />OKEYNOTE NUMBER <br />A REVISION NUMBER <br />2 FIRE PROTECTION - NEW <br />SCALE: 1/4" =1'-0" <br />PIPE RING <br />ANCHOR TO STRUCTURE <br />THREAD ROD <br />END PORTION SHALL HOLD PIPING W PLACE <br />4 PIPE HANGER DETAIL <br />SCALE: NOT TO SCALE <br />" 1SYnTr&A <br />DROI <br />1" NPT FEM, <br />COUPLING I <br />SPRINKLER I <br />COVER PIX <br />ASSEMBLY <br />FINISHED CEILING —/ <br />COVER PLATE <br />3 TYPICAL CONCEALED PENDENT SPRINKLER HEAD DETAIL <br />SCALE: NOT TO SCALE <br />FIRE SPRINKLER SCHEDULE <br />MARK <br />TEMPERATURE <br />SPRINKLER <br />TYPE <br />MANUFACTURER <br />PRESSURE <br />FLOW <br />SIZE <br />K FACTOR <br />RESPONSE <br />TYPE <br />NOTES <br />r♦ <br />165 DEG F <br />CONCEALED <br />VIKING <br />7.0 <br />14.6 <br />1/2" <br />5.6 <br />QUICK <br />1 <br />NOTES: <br />1. PLATE SHALL BE CONCEALED TYPE COLOR TO WHITE UNLESS OTHERWISE NOTED BY ARCHITECT. <br />FIRE PROTECTION - DEMO <br />SCALE: 1/4" = l'-O" <br />GENERAL NOTES <br />1. EXISTING SYSTEMS SHOWN HEREIN WERE TAKEN FROM <br />DOCUMENTS FURNISHED BY OTHERS AND MAY NOT <br />REFLECT EXACT FIELD CONDITIONS. THEREFORE, THE <br />ENGINEER CAN NOT GUARANTEE THE ACCURACY OF <br />SAME, NOR THAT ALL SYSTEMS AND/OR SYSTEMS <br />COMPONENTS ARE SHOWN. THE CONTRACTOR SHALL <br />VERIFY FIELD CONDITIONS PRIOR TO BID AND INFORM THE <br />ENGINEER OF ANY MAJOR DISCREPANCY THAT IT WILL <br />REQUIRE RELOCATING EXISTING PIPING, CONDUIT, <br />EQUIPMENT, ETC. TO ALLOW INSTALLATION OF NEW <br />WORK AND COULD POTENTIALLY AFFECT THE COST. <br />2. REFER TO INFECTION CONTROL RISK ASSESSMENT IN <br />PROJECT MANUAL FOR REQUIRED PREVENTIVE <br />MEASURES TO BE TAKEN FOR EACH AREA. <br />3. BUILDING TO BE FULLY SPRINKLERED. REFER TO LIFE <br />SAFETY DRAWINGS FOR ADDITIONAL INFORMATION. <br />4. PENDENT SPRINKLERS INSTALLED IN CEILINGS SHALL BE <br />CONCEALED TYPE, WITH COLOR APPROVED BY THE <br />ARCHITECT, <br />5. SYSTEM IS A WET AUTOMATIC SPRINKLER SYSTEM. THE <br />DESIGN APPROACH SHALL BE THE AREA DENSITY METHOD <br />UTILIZING A DENSITY OF 0.1 GPM PER FOOT SQUARED <br />(LIGHT HAZARD OCCUPANCY). THE CALCULATION SHALL <br />BE FOR THE MOST HYDRAULICALLY REMOTE 1,500 <br />MINIMUM SQUARE FEET OF PROJECT REGARDLESS OF <br />REDUCTIONS ALLOWED IN NFPA. HOSE STREAM <br />ALLOWANCE SHALL BE 250 GPM ADDED AT THE NEAREST <br />SITE FIRE HYDRANT. COVERAGE PER SPRINKLER SHALL BE <br />MAXIMUM 225 SQ.FT. WITH A MAXIMUM SPACING OF 15'-0". <br />6. INSTALL THE PIPING GRID IN SUPPORT OF THESE LAYOUT <br />REQUIREMENTS AND UTILIZE CONNECTIONS AS <br />NECESSARY TO FEED SPRINKLERS. PROVIDE TEE(S) OR <br />OTHER OUTLETS TO FEED SPRINKLERS AND PLUG <br />UNUSED CONNECTIONS FOR FUTURE USE. CONTRACTOR <br />TO EXTEND SWING JOINT OR ARM OVE THE NEW PENDANT <br />SPRINKLER FROM EXISTING TEES FEEDING DROPS OF <br />EXISTING UPRIGHT/PENDANT HEADS. IF THIS TECHNIQUE <br />IS NOT POSSIBLE, CAP EXISTING TEE (ABANDONING <br />SUPPLY ABOVE CEILING) AND PROVIDE NEW TAP INTO THE <br />EXISTING MAIN OR BRANCH AS NECESSARY. <br />7. SPRINKLER PIPING SHALL NOT PENETRATE STRUCTURAL <br />MEMBERS. THERE IS NO NEED FOR ENGINEERED <br />STRUCTURAL OPENINGS. <br />8. CONTRACTOR SHALL ACCOUNT FOR ANY CROSSMAIN AND <br />BRANCHES PIPING THAT NEEDS TO BE RELOCATED, <br />MODIFIED OR ADJUSTED TO ACCOMMODATE NEW <br />PROPOSED CEILING LAYOUTS. CONTRACTOR SHALL VISIT <br />THE SITE AND BECOME FAMILIAR WITH THE COMPLETE <br />PROPOSED SCOPE AND ITS PHASING (WHERE <br />APPLICABLE) PRIOR TO SUBMITTING A BID FOR THE <br />PROJECT. <br />9. ANYTIME CEILING ELEVATIONS OCCUR, CONTRACTOR <br />SHALL SPACE ALL HEAD IN ACCORDANCE WITH THE <br />OBSTRUCTION RULES OF NFPA 13. <br />10. ALL NEW PIPING SHALL MATCH EXISTING. VERIFY EXISTING <br />PIPING CONSTRUCTION MATERIAL AND THICKNESS. <br />FLEXHEAD ADVENT HEALTH STANDARD: FLEXHEAD® <br />BRAIDED FLEXIBLE CONNECTOR IS THE ONLY ACCEPTABLE <br />FLEXIBLE SPRINKLER HEAD CONNECTION ALLOWED WITH <br />NO SUBSTITUTES OR APPROVED EQUAL PRODUCTS. <br />MOUNTING BRACKET SHALL BE 3" WIDE FLEXHEADS OPEN <br />HUB ADAPTER ONLY. <br />11. THE FIRE SUPPRESSION SYSTEM FOR THIS PROJECT <br />SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE <br />WITH THE FOLLOWING APPLICABLE CODES LISTED ON THE <br />SPECIFICATIONS AND ANY ADOPTED CODES IN THE <br />MUNICIPALITY, <br />12. IS SYSTEM PRESSURE EXCEEDS 100 PSI PROVIDE <br />HANGERS PER NFPA 13 9.2.3.4 AND 9.2.3.5.2 THAT <br />PREVENTS UPWARD MOVEMENT OF THE PIPE FOR <br />SPRINKLERS IN THE PENDENT POSITION. A MAXIMUM OF <br />12" FROM THE END SPRINKLER ON A BRANCH LINE AND ALL <br />ARM-OVERS OVER 12". <br />13. IF NEW BRANCH SPRINKLER LINES ARE REQUIRED, <br />CONTRACTOR SHALL SIZE NEW LINE BASED ON NEW <br />PIPING REQUIREMENTS, ACCOUNTING FOR THE TOTAL <br />NUMBER OF SPRINKLER HEAD LINE IS FEEDING. PIPE <br />SIZING SHALL BE MINIMUM AS FOLLOW UNLESS <br />OTHERWISE INDICATED ON NFPA 13: <br />1" RUNOUTS & 1-2 HEADS <br />1-1/4" 3 HEADS <br />1-112" 4-5 HEADS <br />2" 5 HEADS OR MORE BACK TO MAIN <br />3" CROSSMAINS <br />4" TO 6" MAINS <br />KEYED NOTES: <br />1 CONTRACTOR TO VERIFY IF EXISTING SPRINKLER HEAD <br />MATCH CONCEALED TYPE (ADVENTHEALTH STANDARD). IF <br />SPRINKLER HEADS ARE NOT PER STANDARD, DEMO EXISTING <br />SPRINKLER HEAD AND REPLACE WITH NEW CONCEALED <br />HEAD AS SCHEDULED. <br />2 CONTRACTOR TO RELOCATE ALL EXISTING SPRINKLER <br />HEADS TO CENTER OF THE TILES TO ACCOMMODATE NEW <br />CEILING LAYOUT. <br />3 DURING CONSTRUCTION, CONTRACTOR TO TURN FIRE <br />SPRINKLER LINES UPWARD AND INSTALL UPRIGHT FIRE <br />SPRINKLERS TO MAINTAIN SPRINKLER COVERAGE OR <br />PROVIDE FIRE WATCHES AS PER NFPA 101 MAINTAIN ALL <br />REQUIRED FIRE WATCH LOGS. COORDINATE SPRINKLER <br />PIPE SHUTDOWN WITH OWNER AND OBTAIN WRITTEN <br />PERMISSION TO PROCEED. PROVIDE FIRE WATCH FOR THE <br />SHUTDOWN PERIOD. <br />106 WEST NORTH BAY STREET I TAMPA, FL 33603 <br />www.cjaegroup.com <br />JCL. <br />ENGINEERING <br />MECHANICAL - ELECTRICAL -PLUMBING <br />800 HIGHLAND AVE. STE 102 <br />ORLANDO, FL 32803 <br />CA LIC. NO,: $1963 <br />PHONE: (407) 250-8486 <br />WWW.DCL-ENG.COM <br />STAMPS AND APPROVALS <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A <br />DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF FLORIDA. <br />TO THE BEST OF MY KNOWLEDGE THESE PLANS AND SPECIFICATIONS <br />COMPLY WITH THE APPLICABLE BUILDING CODES. <br />DANIEL CESAR, PE; LICENSE NO: 68670 <br />In <br />AdventHealtV. <br />I - <br />PROJECT NAME <br />ADVENT HEALTH ZEPHYRHILLS ROOM 6 <br />X-RAY REPLACEMNET <br />PROJECT LOCATION <br />7050 GALL BOULEVARD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT NUMBER <br />2021-009 <br />PROJECT PHASE <br />100% CONSTRUCTION DOCUMENTS <br />ISSUE DATE <br />AUGUST 18, 2021 <br />REVISIONS LIST <br />NO. I DATE I DESCRIPTION —� <br />SHEET TITLE <br />FIRE PROTECTION <br />PLANS - DEMO IS <br />NEW <br />SHEET NO. <br />Fpl 01 <br />