My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (118)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (118)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:37:32 AM
Creation date
2/19/2025 1:08:56 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Berglund
Building Plans - Permit #
783
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br />3 <br />4 <br />5 <br />M■ <br />M■ <br />9 <br />A <br />DESIGN SELECTION: SQUARE ' D' NF PANELBOARD <br />MAIN BREAKER: AMPS _ POLE <br />MAIN LUGS: 250 AMPS <br />K.A.I.C.: 65 AMPS <br />SURFACE MTD: X <br />FLUSH MTD: <br />3 PHASE <br />4 WIRE <br />208V/120V <br />X 480V/277V <br />24OV/120V <br />Name: <br />Project Name: <br />Project Number: <br />Fed From: <br />Location: <br />NHK <br />(NEW NORMAL BRANCH) <br />MSB (LOCATED IN CEP) <br />ELEC. 116A <br />N <br />C <br />TLoad <br />Name <br />Trip <br />Poles <br />A <br />B <br />C <br />Poles <br />Trip <br />Load Name <br />C <br />T <br />N <br />O <br />1 <br />LIGHTING - HOSPITAL <br />20 A <br />1 <br />0.4 <br />0.0 <br />1 <br />20 A <br />SPARE <br />2 <br />3 <br />TEMP WASHER <br />30 A <br />3 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />4 <br />5 <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />6 <br />7 <br />-- <br />-- <br />-- <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />8 <br />9 <br />T-NLK <br />125 A <br />3 <br />14.6 <br />0.0 <br />1 <br />20 A <br />SPARE <br />10 <br />11 <br />-- <br />1 <br />-- <br />-- <br />32.2 <br />0.0 <br />1 <br />20 A <br />SPARE <br />12 <br />13 <br />-- <br />-- <br />-- <br />22.7 <br />0.0 <br />1 <br />20 A <br />SPARE <br />14 <br />15 <br />0.0 <br />1 <br />20 A <br />SPARE <br />16 <br />17 <br />0.0 <br />1 <br />20 A <br />SPARE <br />18 <br />19 <br />0.0 <br />1 <br />20 A <br />SPARE <br />20 <br />21 <br />EF2-1 <br />20 A <br />1 3 <br />2.8 <br />0.0 <br />1 <br />20 A <br />SPARE <br />22 <br />23 <br />-- <br />-- <br />-- <br />2.8 <br />0.0 <br />1 <br />20 A <br />SPARE <br />24 <br />25 <br />-- <br />-- <br />-- <br />2.8 <br />1 0.0 <br />1 <br />20 A <br />SPARE <br />26 <br />27 <br />EF2-3 <br />15 A <br />3 <br />0.3 <br />0.0 <br />1 <br />20 A <br />I SPARE <br />28 <br />29 <br />-- <br />-- <br />-- <br />0.3 <br />0.0 <br />1 <br />20 A <br />SPARE <br />30 <br />31 <br />-- <br />-- <br />-- <br />0.3 <br />0.0 <br />1 <br />20 A <br />SPARE <br />32 <br />33 <br />EF2-2 <br />15 A <br />3 <br />0.9 <br />0.0 <br />1 <br />20 A <br />SPARE <br />34 <br />35 <br />-- <br />-- <br />-- <br />1 <br />0.9 <br />0.0 <br />1 <br />20 A <br />SPARE <br />36 <br />37 <br />-- <br />-- <br />-- <br />0.9 <br />0.0 <br />1 <br />20 A <br />SPARE <br />38 <br />39 <br />AHU-3A <br />15 A <br />3 <br />- <br />0.3 <br />0.0 <br />1 <br />20 A <br />I SPARE <br />40 <br />41 <br />-- <br />-- <br />-- <br />0.3 <br />0.0 <br />1 <br />20 A <br />SPARE <br />42 <br />43 <br />-- <br />-- <br />-- <br />0.3 <br />0.0 <br />1 <br />20 A <br />SPARE <br />44 <br />45 <br />LIGHTING - HOSPITAL <br />20 A <br />1 <br />0.1 <br />0.0 <br />1 <br />20 A <br />SPARE <br />46 <br />47 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />48 <br />49 <br />SPARE <br />20 A <br />1 <br />1 0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />50 <br />51 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />52 <br />53 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />54 <br />55 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />56 <br />57 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />58 <br />59 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />60 <br />61 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />62 <br />63 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />64 <br />65 <br />SPARE <br />20 A <br />1 <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />66 <br />67 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />68 <br />69 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />70 <br />71 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />72 <br />73 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />120 A <br />SPARE <br />74 <br />75 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />76 <br />77 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />78 <br />79 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />3 <br />30 A <br />SPD <br />80 <br />81 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />-- <br />-- <br />-- <br />82 <br />83 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />-- <br />-- <br />-- <br />84 <br />Notes: <br />Phase Connected Load: <br />Lighting - Hospital <br />Receptacle <br />Motor <br />Heating <br />Cooling <br />Other <br />Elevator <br />Spare <br />X-Ray <br />Kitchen Equipment - Non -Dwelling Unit <br />27.5 kVA 19.0 kVA <br />CONN. DEMAND DEMAND <br />LOAD... FACTOR LOAD... <br />0.5 kVA 40.00% 0.2 kVA <br />24.8 kVA 70.16% 17.4 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />13.8 kVA 85.00% 11.7 kVA <br />44.0 kVA 100.00% 44.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />36.6 kVA <br />Total Connected Load: 83.1 kVA <br />Total Demand Load: 73.3 kVA <br />Demand Amps: 88 A <br />2 <br />SQUARE 'D' NQ PANELBOARD (3 SECTION, 42 CKT EACH) <br />Name: NIX <br />(NEW NORMAL BRANCH) <br />MAIN BREAKER: 300 AMPS _ POLE 3 PHASE Project Name: <br />MAIN LUGS: AMPS 4 WIRE Project Number: <br />K.A.I.C.: 42 AMPS X 208V/120V Fed From: NHK (XFMR T-NLK) <br />SURFACE MTD: X 480V/277V Location: ELEC. 116A <br />FLUSH MTD: 24OV/120V <br />N <br />o <br />C <br />T <br />Load Name <br />Trip <br />Poles <br />A <br />B <br />C <br />Poles <br />Trip <br />Load Name <br />C <br />T <br />N <br />O <br />1 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />0.2 <br />1.2 <br />1 <br />20 A <br />RECEPTACLE <br />2 <br />3 <br />KITCHEN EQUIPMENT SERVERY <br />20 A <br />1 <br />0.2 <br />2.3 <br />3 <br />15 A <br />BLOWER DRYER <br />4 <br />5 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />0.2 <br />2.3 <br />1 -- <br />-- <br />-- <br />6 <br />7 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />0.8 <br />2.3 <br />3 <br />9 <br />EF1-1 <br />15 A <br />2 <br />0.3 <br />7.0 <br />1 <br />15 A <br />BOOSTER PUMP <br />10 <br />11 <br />-- <br />-- <br />-- <br />0.3 <br />0.0 <br />13 <br />KITCHEN EQUIPMENT SERVERY <br />20 A <br />2 <br />0.1 <br />0.0 <br />1 <br />20 A <br />SPARE <br />14 <br />5 <br />15 <br />-- <br />-- <br />-- <br />0.1 <br />13.0 <br />2 <br />35 A <br />WASHER <br />16 <br />17 <br />KITCHEN EQUIPMENT SERVERY <br />20 A <br />2 <br />0.1 <br />13.0 <br />-- <br />-- <br />I -- <br />18 <br />19 <br />-- <br />-- <br />-- <br />0.1 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />20 <br />/\ <br />21 <br />KITCHEN EQUIPMENT SERVERY <br />20 A <br />2 <br />0.1 <br />0.0 <br />1 <br />20 A <br />SPARE <br />22 <br />126 <br />3 <br />23 <br />-- <br />-- <br />-- <br />0.1 <br />0.2 <br />1 <br />20 A <br />OTHER <br />24 <br />25 <br />RECEPTACLE <br />30 A <br />2 <br />1.0 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />27 <br />-- <br />-- <br />-- <br />1.0 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />28 <br />29 <br />KITCHEN E UPMENT SERVERY <br />20 A <br />1 <br />0.0 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />30 <br />31 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />0.2 <br />0.8 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />32 <br />33 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />1.0 <br />0.6 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />34 <br />35 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />0.2 <br />0.1 <br />2 <br />15 A <br />KITCHEN EQUIPMENT <br />36 <br />37 <br />RECEPTACLE SERVERY <br />25 A <br />1 <br />1.2 <br />0.1 <br />-- <br />-- <br />-- <br />38 <br />39 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />0.2 <br />0.1 <br />3 <br />20 A <br />KITCHEN EQUIPMENT <br />40 <br />41 <br />RECEPTACLE SERVERY <br />20 A <br />1 <br />0.2 <br />0.1 <br />-- <br />-- <br />-- <br />42 <br />43 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.8 <br />0.1 <br />1 <br />1 <br />-- <br />-- <br />-- <br />44 <br />45 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />1.0 <br />0.8 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />46 <br />47 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.8 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />48 <br />49 <br />1 RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />1.0 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />50 <br />51 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.2 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />52 <br />53 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.2 <br />0.8 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />54 <br />55 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.2 <br />0.8 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />56 <br />57 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.8 <br />0.8 <br />1 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />58 <br />59 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.2 <br />0.8 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />60 <br />1611 <br />TEMP KITCHEN EQUIPMENT <br />20 A <br />2 <br />0.1 <br />1 0.4 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />62 <br />63 <br />-- <br />-- <br />I -- <br />0.1 <br />0.8 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />64 <br />65 <br />TEMP KITCHEN EQUIPMENT <br />20 A <br />2 <br />0.1 <br />0.2 <br />1 <br />20 A <br />KITCHEN EQUIPMENT <br />66 <br />67 <br />-- <br />-- <br />-- <br />0.1 <br />0.0 <br />1 <br />20 A <br />COOLING <br />68 <br />69 <br />TEMP KITCHEN EQUIPMENT <br />20 A <br />2 <br />0.1 <br />0.2 <br />1 <br />20 A <br />KITCHEN EQUIPMENT <br />70 <br />71 <br />-- <br />-- <br />-- <br />0.1 <br />0.2 <br />1 <br />20 A <br />KITCHEN EQUIPMENT <br />72 <br />73 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.2 <br />0.2 <br />1 <br />1 <br />20 A <br />KITCHEN EQUIPMENT <br />74 <br />3 <br />75 <br />TEMP KITCHEN EQUIPMENT <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />76 <br />77 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.2 <br />1.0 <br />2 <br />30 A <br />RECEPTACLE KITCHEN <br />78 <br />79 <br />RECEPTACLE TEMP KITCHEN <br />20 A <br />1 <br />0.2 <br />1.0 <br />-- <br />-- <br />-- <br />80 <br />81 <br />TEMP KITCHEN EQUIPMENT <br />20 A <br />1 <br />0.0 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />82 <br />83 <br />TEMP KITCHEN EQUIPMENT <br />20 A <br />1 <br />0.0 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />84 <br />85 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.2 <br />1 <br />20 A <br />RECEPTACLE KITCHEN <br />86 <br />87 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.7 <br />3 <br />30 A <br />RECEPTACLE KITCHEN <br />88 <br />89 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.7 <br />-- <br />-- <br />-- <br />90 <br />91 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.7 <br />-- <br />-- <br />-- <br />92 <br />93 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.2 <br />1 <br />25 A <br />RECEPTACLE KITCHEN <br />94 <br />95 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />96 <br />97 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />98 <br />99 <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />... <br />I SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />1 <br />20 A <br />SPARE <br />... <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />1 <br />20 A <br />SPARE <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />3 <br />30 A <br />SPD <br />... <br />SPARE <br />20 A <br />1 <br />0.0 <br />0.0 <br />-- <br />-- <br />-- <br />... <br />SPARE <br />20 A <br />1 <br />0.0 1 <br />0.0 <br />-- <br />-- <br />-- <br />Phase Connected Load: 14.6 kVA 32.2 kVA 22.7 kVA 2 <br />1 <br />Lighting - Hospital <br />Receptacle <br />Motor <br />Heating <br />Cooling <br />Other <br />Elevator <br />Spare <br />X-Ray <br />Kitchen Equipment - Non -Dwelling Unit <br />Total Connected Load: 69.4 kVA <br />Total Demand Load: 61.9 kVA <br />Demand Amps: 172 A <br />Notes: <br />CONN. <br />LOAD... <br />DEMAND <br />FACTOR <br />DEMAND <br />LOAD... <br />0.0 kVA <br />0.00% <br />0.0 kVA <br />24.8 kVA <br />70.16% <br />17.4 kVA <br />0.0 kVA <br />0.00% <br />0.0 kVA <br />0.0 kVA <br />0.00% <br />0.0 kVA <br />0.6 kVA <br />85.00% <br />0.5 kVA <br />44.0 kVA <br />100.00% <br />44.0 kVA <br />0.0 kVA <br />0.00% <br />0.0 kVA <br />0.0 kVA <br />0.00% <br />0.0 kVA <br />0.0 kVA <br />0.00% <br />0.0 kVA <br />0.0 kVA <br />0.00% <br />0.0 kVA <br />DESIGN SELECTION: SQUARE D NF PANELBOARD <br />MAIN BREAKER: AMPS _ POLE <br />MAIN LUGS: 400 AMPS <br />K.A.I.C.: 35 AMPS <br />SURFACE MTD: X <br />FLUSH MTD: <br />3 PHASE <br />4 WIRE <br />208V/120V <br />X 480V/277V <br />24OV/120V <br />Name: <br />Project Name: <br />Project Number: <br />Fed From: <br />Location: <br />EOHK <br />(NEW EQUIPMENT BRANCH) <br />ELEC. 116A <br />N <br />0 <br />C <br />T <br />Load Name <br />Trip <br />Poles <br />A <br />B <br />C <br />Poles <br />Trip <br />Load Name <br />C <br />T <br />N <br />O <br />5 <br />------------ <br />2.2 <br />8.6 <br />3 <br />70 A <br />T-E LK <br />2 <br />3 <br />POWER <br />SOAK <br />30 A <br />3 <br />0.8 <br />8.2 <br />-- <br />-- <br />-- <br />4 <br />5 <br />-- <br />-- <br />-- <br />0.8 <br />8.8 <br />-- <br />-- <br />-- <br />6 <br />7 <br />-- <br />-- <br />-- <br />0.8 <br />0.0 <br />-- <br />-- <br />SPACE <br />8 <br />0.0 <br />-- <br />-- <br />SPACE <br />10 <br />11 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />12 <br />13 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />14 <br />15 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />16 <br />17 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />18 <br />19 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />20 <br />21 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />22 <br />23 <br />1 SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />24 <br />25 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />26 <br />27 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />28 <br />29 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />30 <br />31 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />32 <br />33 <br />1 SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />34 <br />35 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />36 <br />37 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />38 <br />39 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />40 <br />41 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />42 <br />43 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />44 <br />45 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />- <br />SPACE <br />46 <br />47 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />48 <br />49 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />50 <br />51 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />52 <br />53 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />54 <br />55 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />56 <br />57 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />58 <br />59 <br />1 SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />60 <br />61 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />62 <br />63 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />64 <br />65 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />66 <br />67 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />68 <br />69 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />70 <br />71 <br />SPACE <br />1 <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />72 <br />73 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />74 <br />75 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />76 <br />77 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />SPACE <br />78 <br />79 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />3 <br />30 A <br />SPD <br />80 <br />81 <br />SPACE <br />-- <br />-- <br />0.0 <br />0.0 <br />-- <br />-- <br />-- <br />82 <br />83 <br />SPACE <br />1 <br />0.0 <br />0.0 <br />-- 1 <br />184 <br />Notes: <br />Phase Connected Load: <br />Lighting - Hospital <br />Receptacle <br />Motor <br />Heating <br />Cooling <br />Other <br />Elevator <br />Spare <br />X-Ray <br />Kitchen Equipment - Non -Dwelling Unit <br />11.6 kVA 9.0 kVA <br />CONN. DEMAND DEMAND <br />LOAD... FACTOR LOAD... <br />2.2 kVA 40.00% 0.9 kVA <br />2.8 kVA 100.00% 2.8 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />17.0 kVA 85.00% 14.5 kVA <br />8.3 kVA 100.00% 8.3 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />0.0 kVA 0.00% 0.0 kVA <br />9.6 kVA <br />Total Connected Load: 30.3 kVA <br />Total Demand Load: 26.5 kVA <br />Demand Amps: 32 A <br />2 <br />i <br />RS&H <br />1715 N. Westshore Blvd., Suite 600 <br />Tampa„ Florida 33607-3999 <br />904-256-2500 Fax 904-256-2503 <br />www.rsandh.com <br />FL Cert. Nos. AAC001886 * IB26000956 <br />5620 * LCC000210 * GB238 <br />TLC <br />ENGINEERING <br />SOLUTIONS® <br />255 S. Orange Avenue <br />Suite 1600 <br />Orlando, FL 32801 <br />P 407.841.9050 <br />www.tic-engineers.com <br />COA 15 <br />© Copyright 2019 TLC Engineering Solutions, Inc. <br />TLC Project No.: 119333 <br />THINK. LISTEN. CREATE. <br />PROJECT TITLE: <br />i W ROF 1. AM <br />90 <br />PROJECT ADDRESS: <br />7050 Gall Blvd. Zephyrhills, FL 33541 <br />Christopher V. O'Hara, P.E. <br />Florida License #66504 <br />%%�OTHER � , o� <br />V' No 66504 .•'7 <br />0: =��'� <br />0'.. STATE OF <br />Digitally •'lay �H Q��� ��iA <br />DN: C�.D <br />OU=A0141 N� 1,35Qdh3D07, <br />�WN O=TLC EN IN � S, C=US <br />Date: 2021.02.04 13:2 : 5'00' pp <br />Cj <br />V <br />V <br />REVISIONS <br />NO. <br />DESCRIPTION <br />DATE <br />1 <br />REVISION 1 <br />06/15/2020 <br />2 <br />ADDENDUM NO.1 <br />07/17/2020 <br />3 <br />CCD #1 <br />01/07/2021 <br />5 <br />CCD #2 <br />02/03/2021 <br />DATE ISSUED: 03/20/2020 <br />REVIEWED BY: CVO <br />DRAWN BY: MA <br />DESIGNED BY: MA <br />PROJECT NUMBER: <br />5W- 0226- 000 <br />© 2019 RS&H, INC. <br />SHEET TITLE: <br />PANEL SCHEDULES <br />SHEET ID: <br />-=11I-1 <br />Copyright © 2018. This drawing is an instrument of service and property of RS&H, Inc. Any use or reproduction without the <br />expressed written consent of this corporation is prohibited. All rights reserved. <br />2 <br />3 <br />4 <br />5 <br />PROJECT STATUS: <br />CONSTRUCTION <br />DOCUMENTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.