OAaE-flO <br />ROOF WIND DESIGN PRESSURES <br />NET (GROSS) ASCE 7-16 <br />ZONE 1 •61.20 PSF (71.20) <br />ZONE 3 • 70.70 PSF (90.70) <br />ZONE 2e • 70.70 PSF (80.70) <br />ZONE 3e • 82.90 PSF (92.90) <br />ZONE 2n • 8240 PSF (92.90) <br />ZONE 3r • 90.80 PSF (100.80) <br />ZONE 2, • 82.90 PSF (92.90) <br />W- 4'-0- END ZONE DISTANCE <br />BASIC WIND SPEED: ISO MPH <br />EXPOSURE CATEGORY:"C. <br />RISK CATAGORY: II <br />APPLICABLE INTERNAL <br />PRESSURE COEFFICIENT: +/- 0.18 <br />ROOF DIAPHRAGM <br />FOR ASPHALT SHINGLE ROOF, USE MIN 19/37' STRUCTURAL SHEATHING <br />EXP 1 4020 FOR CEMENTITIOUS TILE AN METAL ROOFING, <br />( ), D O NG, USE MIN. <br />19r"' STRUCTURAL SHEATHING EXP 1 (402O)(SEE TABLE FOR FIELD <br />AND EDGE SPACING) SEE DETAIL <br />ROOF SHEATHING TO GABLE END FRAME USE 1Od RING SHANK GUN <br />NAILS ®4" O.C. EDGEWISE 2X4 BLOCKING ALL PANEL JOINTS W/ IN 4- OF <br />GABLE END. <br />ROOF/ WALU FLOOR <br />SHEATHING <br />FASTENER SCHEDULE <br />SIZE <br />HEAD <br />LENGTH <br />DIA. <br />TENSILE SIR. <br />SHANK <br />ASTM <br />10d <br />RING SHANK <br />2 12' <br />0.131 <br />F1 <br />SCREW SHANK <br />170,000 <br />RING <br />'IN RINGS <br />PER <br />RSRS-03 <br />Bd <br />RING SHANK, <br />2 3/B" <br />0.113 <br />R 667 <br />SCREW SHANK <br />INCH) <br />Sd <br />RING SHANK, <br />PNEUMATIC <br />23/B' <br />0.113 <br />F1867 <br />SCREW -NAILS <br />RSRS-01 <br />ROOF SHEATHING <br />EXTERIOR SHEATHING <br />Z <br />USE 1/7' CDX OR 7/16' O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4" <br />9 O <br />O.C. AT PANEL SIDES AND Bd RING SHANK GUN NAILS 4" O.C. TOP 8 <br />3 <br />BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT B' O.C. AT <br />m <br />INTERMEDIATE SUPPORTS OR 7/16' ZIP SHEATHING SYSTEM (INSTALLED <br />PER MANUF. SPECS.) SEE DETAIL <br />BUILDING LENGTH <br />ROOF SHEATHING LAYOUT <br />AND ENOWALL BRACING <br />FOR GABLE END FRAMING <br />ROOF SHEATHING ATTACH EMENT SPACING <br />ZONE 1: 10d NAILS 4" O.C. ON EDGE AND 8" O.C. IN FIELD <br />NOTE. GABLES -DROP GABLE END 8 (1) ADD'L DROPPED <br />ZONE 2e, 2n, 2r: 10d NAILS 4" O.C. ON EDGE AND 4" O.C. INFIELD <br />Q <br />TRUSS 2X4 92 SYP OUTLO.KER RAFTER W/ BLOCKING <br />ZONE 3,3e, 3r: tOd NAILS Q 4" O.C. ON EDGE AND 4" O.C. IN FIELD <br />16"0 C. IF NO DROPPED GABLE END, ATTACH 2X4 #2 SYP <br />BLOCKING ® 16" O.C. FIRST 4 BAYS W/ (2)120 NAILS EA. <br />END. ATTACH ROOF SHEATHING TO RAFTERS 2/ <br />NOTE: ROOF SHEATHING THICKNESS WAS CALCULATED <br />BLOCKING PER NAILING SCHEDULE <br />AND ADHERES TO ASCE 7-16 <br />8d RING SHANK GUN NAILS Q 4" O.C. <br />' <br />.- TOP 8 BOTTOM EDGES .. <br />a <br />z <br />z <br />0 o <br />QZ W <br />2 � <br />N U <br />z 0 <br />rn <br />zw <br />O Ow <br />C 1. RING SHANK GUN NAILS <br />U <br />SEE "ROOF SHEATHING ATTACHMENT" <br />TABLE FOR FIELD SPACING <br />.0 <br />\ <br />z< <br />J\ <br />R <br />�Ag 2' DECK SCREWS 0 S"A" O.C. MAX <br />EDGES 8/7' O.C. MAX IN FIELD. UNTHREADED <br />SHANK TO EXTEND BEYOND THICKNESS OF <br />SUB -FLOOR SHEATHING <br />TYP. N4" T8G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS <br />GENERAL NOTES: <br />ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33C33A MAXIMUM AGGREGATE Siff SHALL BE 314' <br />STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WTH JOB SPECIFICATIONS AND <br />WOOD: <br />ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS . CONSULT <br />PROVIDE g%AIR B4IFWNED CONCRETE EXPOSED TO EARTH OR WEATHER <br />NON -BEARING WOOD WALLS TOP PLATES 8 STUDS CAN BE SPF. <br />ARCHITECTURAL DRAWINGS FOR SLEEVES,DEPRESSIONS, AND OTHER DETAILS NOT SHOWN <br />ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBGR 2020, 71N EDITION <br />ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMlSRE07K. <br />ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, <br />ACI 315.14, BUILDING CODE REQUIREMENTS <br />CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE N0. 2 OR BETTER. Fb = 1100 PSI AND A MODULUS OF <br />FOR STRUCTURAL CONCRETE, TMS 4021602-16 AISI SPECIFICATION FOR THE DESIGN OF <br />pRpylpE g#N CONTINUOUS POLYETHYLENE VAPOR BARRIER NEN&tANE UDER ALL SIA&SONl 0U1q WHERE OpICA7gI pry <br />AL CONMS <br />BARRIE MEMERIVE <br />INUOUAPPED <br />ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE <br />COLD -FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 AND AISC SPECIFICATIONS <br />�VA� S BONES AND SEALEDVAPOR <br />E <br />PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NONSTRUCTURAL USES <br />SHALL BE RATED TO RETENTION LEVELS OF 0,25 PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM <br />ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />FORM -WORK: <br />CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY <br />SWILL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, <br />REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. HAULS, SPIKE, BOLTS USED <br />EXCEPT VMERE A DIFFERENT DETAIL IS SHOWN. <br />AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347 LATEST <br />WI DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT <br />EDITION; RECOMMENDED PRACTICE FOR CONCRETE FORMAAORK. <br />CONTAINS MORE THAN W OF HEARTWOOD. <br />ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE <br />DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY ANY DISCREPANCIES SHALL BE BROUGHT <br />EXCLUSIONS FROM THESE PLANS: <br />MINIMUM NAIUNG PER FBCR 2020, 7BI EDITION. SEE NAILING SCHEDULE ON PLANS. <br />TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART <br />WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS <br />OF THE WORK. <br />ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL. DEPENDING <br />PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2X STRUCTURAL LUMBER <br />ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. <br />SYP @2. <br />THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING <br />IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBIUTY TO DETERMINE ERECTION PROCEDURES AND <br />UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED <br />SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS <br />WELDED WIRE MESH: <br />AT BEARING LOCATIONS W THOUT WOODEN TOP PLATES. <br />DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, <br />TEMPORARY BRACING, GUYS OR TIE4XMNS. <br />WELDED HARE MESH, SHALL BE ASTM A1084/A10B4M, GRADE 85 AND BE PLACED IN ACCORDANCE WITH THE <br />ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SUBS SHALL <br />WOOD TRUSSES: <br />THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION <br />BE SUPPORTED WTH 2' CHAIRS SPACED T-O' OC, EACH WAY. <br />TO BE DESIGNED AND FABRICATED IN ACCORDANCE WTH THE'NATIONAL DESIGN SPECIFICATIONS FOR <br />REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. <br />STRESSGRAOE LUMBER AND ITS FASTENINGS' BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND <br />SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. <br />DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL <br />TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM ASISA615M GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615 <br />GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE <br />DESIGN LOADS: W THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. <br />CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL <br />ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 pd AND VERTICAL BARS SHALL LAP 6 K BAR NO. UNSCHEDULED FIELD UPS ARE SUBJECT TO ENGINEERS <br />REVIEW. <br />20 pd TOP CHORD tl—rMAlrlenl <br />TYP. MIN UPS SHALL BE AS FOLLOWS: 44 BAR - 25' NB BAR - 38" <br />70 pd BTM CHORD-nmconwrteM /5 BAR - 30" 07 BAR - 47 <br />PROVIDE 36' c 36' CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS <br />DEAD LOAD DEAD LOAD FOR ADDITIONAL INFORMATION. <br />18 pd TOP CHORD 20 psf TOP CHORD <br />(7 Pit W/ ASPHALT SHINGLES) 00 P f w/ NO GYPCRETE) <br />10 paf BTM CHORD 5 pd BTM CHORD <br />DEAD LOAD TO RESIST WHO UPLIFT. 1Opsf <br />BALCONY LIVE LOAD 60 psf <br />STAIRS LIVE LOAD 40 Pat <br />CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.038' AND BE MANUFACTURED FROM STEEL <br />MEETING THE REQUIREMENTS OF ASTM A448/A446M, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. <br />DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WTH TPI-14, -DESIGN NATIONAL <br />STANDARDS FOR METAL-PLATECONNECTED-WOOD TRUSS CONSTRUCTION., AND 'BCSI LATEST EDITION" <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METALALATE-CONNECTED <br />WOOD TRUSSES. <br />TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF <br />LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR <br />INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI/ASCE 7 88'. 1990. <br />ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. <br />THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH <br />MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT <br />WALL. TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. <br />WIND: DEAD LOAD SPEED =ISO MPH 3- SECOND GUST <br />RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL <br />ROOF 8 FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING <br />(ASCE 7-18 (FBC R2020) EXPOSURE C, RISK CATEGORY II) <br />INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. <br />DETERMINATIONS, FEASIBILITY 8 ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL <br />LIVE LOADS. UNINHABITABLE ATTIC WITHOUT STORAGE' 10psf, UNINHABITABLE ATTIC WITH LIMITED <br />LAYOUT, SPANS 8 ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT <br />STORAGE. 2DPW, HABITABLE ATTICS AND ATTICS SERVED WTH FIXED STAIRS: 3W,, BALCONIES (EXTERIOR) <br />DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS <br />AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE <br />AND DECKS: 40Psf, GUARDS AND HANDRAILS'. 200pd, GUARD IN -FILL COMPONENTS: 5OPet, PASSENGER <br />WITHOUT THE APPROVAL OF THE ENGINEER. <br />STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL <br />VEHICLE GARAGES: 50pef, ROOMS OTHER THAN SLEEPING ROOM: 40pd, SLEEPING ROOMS: 30psf, STAIRS: <br />PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION <br />40psf <br />MASONRY: <br />PLAN SHOW NG COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA <br />MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE <br />LICENSED PROFESSIONAL ENGINEER. <br />SHOP DRAWING REVIEW; <br />"SPECIFICATION MASONRY STRUCTURES' (TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY <br />SHOP DRAWINGS WILL BE RENEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT <br />STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS PUBLISHED BY <br />THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PUNS ARE PROVIDED TO FACILITATE THE <br />CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS <br />OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br />THE MASONRY STANDARDS JOINT COMMITTEE. <br />PROVIDED BY THE TRUSS ENGINEER. <br />COMPLIANCE WTH THE CONTRACT DOCUMENTS AS TO QUANTITY LENGTH ELEVATIONS DIMENSIONS, . E ETC <br />BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK <br />THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PUN SHALL SUPERCEDE TNENT <br />ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. <br />MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE frn = 2000 PSI. BLOCK SHALL BE PLACED USING <br />OF THE DELEGATED TRUSS ENGINEER. HAND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-16 COMPONENT <br />AND CLADDING W ND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SMALL BE RESPONSIBLE FOR <br />DRAWINGS SUBMITTED WITHOUT RENEW HALL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM <br />RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE <br />PLACINGCONCRETE F I <br />ALL TRUSS TO TRUSS CONNECTIONS. <br />OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWNGS (CONTRACT DOCUMENTS) ARE PROHIBITED NC OR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WT <br />WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT ASTM C478, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS <br />DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERMSE SPECIFIED IN <br />SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" <br />WRITING BY THE ARCHITECT. <br />COURSE AGGREGATE, AND SHALL BE PLACED W A SLUMP OF 8" TO 10'. USE ONLY MECHANICAL VIBRATION <br />TO CONSOLIDATE GROUT. <br />FOUNDATION/ SITE PREPARATION' <br />FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 pd. FOOTING <br />TYPE "M- OR "S- MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE <br />PROPORTIONED AND MIXED AS OUTUNED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS <br />EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95%OF THE <br />SHALL BE 3f8' THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO <br />MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WTH ASTM 0-1557. TREAT ALL <br />SOIL FOR TERMITE PROTECTION. <br />CELLS TO BE FILLED. <br />THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY <br />SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE <br />GEO-TECHNICAL ENGINEERS REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE <br />CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE <br />MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS NAVE BEEN MET SHALL <br />BE MADE BY THE GEO-TECH. ENGINEER. <br />CONCRETE <br />CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: <br />2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE <br />3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5- STRUCTURAL TERRACE SLAB. <br />CONTRACTOR SHALL SUBW PROPOSED MX DESIGNS. WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MX PRIOR TO <br />CONCRETE PLACEMENT CONCRETE SLUMP SHALL NOT EXCEED F M- PRIOR TO THE ADDITION OF PLASTICIZER <br />CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 318 AND ASTM C94C9/Y OR MEASURING MXWG. TRANSPORTING, <br />ETC. CONCRETE TICKETS SHALL BE TIME TAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN <br />WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MNUTES. IF FOR ANY REASON <br />THERE IS A DELAY W SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MNUrES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL <br />BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNERS REPRESENTATIVE AND THE CONTRACTOR OF ANY <br />NON COMPLIANCE WITH THE ABOVE. <br />RE RED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS'. <br />A 3' FOR CONCRETE CAST AGNNST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS). <br />B. FOR CONCRETE EM-05 D TO EARTH AIO,OR WEATHER <br />1-1/2'FOR IS AND SMALLER <br />Y FOR M AND LARGER <br />C. FOR CONCRETE NOT EXPOSED TO WEATHER <br />314' FOR SLABS, WALLS AND JOISTS <br />1 Art FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS <br />FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL <br />REINFORCING. <br />LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. <br />STRUCTURAL STEEL: <br />THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE <br />SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, <br />9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM <br />AWA36M, Fy - 361m FOR ANGLES, PLATES, AND WSHAPES. STRUCTURAL TUBING SHALL BE ASTM <br />A50OIA500M, GRADE B, Fy - 46 k. STRUCTURAL PIPE SHALL BE ASTM A53/A53M, GRADE B, TYPE E OR S, Fy = <br />35 Wa TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. <br />ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WTH DOUBLE -NUT LEVELING. ALL <br />OTHER BOLTS SHALL BE ASTM F3125IF3125M BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS <br />SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. <br />ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. JSOLTS ARE TO BE STEEL. <br />FASTENER SCHEDULE <br />WINDOW AND <br />DOOR BUCK <br />FASTENERS <br />FASTENER <br />AEvtIG1roN <br />9xE <br />9RApNG <br />RFJIArae <br />AavLiGMN <br />SI1f <br />TVGE <br />ePAC NO <br />gEMARIW <br />I.aoTruR T. <br />— <br />U, w�R�]®mL <br />NNLII LOAD <br />e,� <br />GrRwEDOOReLcyc <br />TO YASONRVA?'xK <br />TAvcon M.9gary <br />ASiENER <br />90A: <br />T. <br />SOLO. AL EFT DOORS <br />a r <br />CAEE IIARDEtm COa <br />YpC <br />9TAOGERFD <br />NNMWORI FASTENED <br />�iMO MASOrNT.CONC <br />MW011 <br />wtV�bA R <br />IXPul4OV BOLT <br />Iractx OA' <br />M'_(l Owl <br />AWED BEND i <br />E TEDDE tlaT� <br />wNocw euac <br />%nDENED DaL <br />rac <br />CONTACT THIS ENGINEER FOR SPACING <br />—LONG <br />REQUIREMENTS <br />h R. e e <br />NOS W,EgtER <br />FASTIER <br />I� <br />t <br />wr VN9tER E BOLT b « , T MT EDGE O& <br />A 1t? �« <br />Ei To eTEE .SEE i wASNER RED rE wEDGE piST t? <br />I STAPLES SHALL HOT BE USED FOR ANY STRUCTURAL APPLICATIONS <br />2. FASTENING OF GARAGE DOORS. W NDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SRALL BE AS PER MANUFACTURERS SPECS AND / OR NOA <br />3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED <br />4. PAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN <br />5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NQA OR THE SPACING DETAILED ABOVE <br />8, WNDOW AND DOOR BUCKS SHALL BE AS WIDE OR W DER AS THE DOOR OR WNDOW FRAME EXCEPT FOR AN EXTERIOR SWING DOOR WTH A WOOD DOOR FRAME. 1. MEMBERS ARE KAILED AND <br />2. MEMBERS ARE SECURED W TAPCONS OR PAF TO THE SUBSTRATE. <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAX 407-7744078 <br />www.abdesWgroup.eom <br />AA M. 0003325 J <br />r <br />b <br />Y <br />9tMD2V. & LOT <br />III <br />ABBOTT PARK <br />LOT #27 <br />BLK. #11 <br />PROJECT <br />04181.000-27111 <br />MODEL& <br />3EEB <br />"2260—ELSTON" <br />GARAGE awIr7G: <br />RIGHT <br />PAGE: <br />DETAILS <br />%160 WH E C <br />