GENERAL NOTES: <br />1. PER FBC ENERGY CONSERVATION SECTION 408.3; PRIOR TO <br />PASSING FINAL INSPECTION, THE DESIGN PROFESSIONAL <br />SHALL PROVIDE EVIDENCE THAT THE LIGHTING CONTROL <br />SYSTEMS HAVE BEEN TESTED TO ENSURE THAT CONTROL <br />HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, <br />PROGRAMMED AND IN PROPER WORKING CONDITION IN <br />ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND <br />MANUFACTURER'S INSTRUCTIONS. FUNCTIONAL TESTING <br />SHALL BE IN ACCORDANCE WITH SECTIONS C408.3.1 AND <br />C408.3.1.2 THROUGH C408.3.1.3 FOR APPLICATION CONTROL <br />TYPE. <br />2. PER FBC ENGERY CONSERVATION SECTION C405.6.4: ALL <br />DRAWINGS AND OPERATING/MAINTENANCE MANUALS SHALL <br />BE PROVIDED TO THE OWNER. <br />3. PER FBC ENGERY CONSERVATION SECTION C408.3.2: ALL <br />DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING <br />CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF <br />SECTION C405 ARE TO BE PROVIDED TO THE OWNER. <br />4. PER NEC 517.13 (2020), ALL BRANCH CIRCUITS SERVING <br />PATIENT CARE AREAS (TREATMENT ROOMS AND BAY AREAS), <br />SHALL BE PROVIDED WITH AN EFFECTIVE GROUND —FAULT <br />CURRENT PATH BY INSTALLATION IN A METAL RACEWAY <br />SYSTEM OR A CABLE HAVING A METALLIC ARMOR OR SHEATH <br />ASSEMBLY. <br />TO BE LOCKED <br />"ERMANENTLY <br />ELECTRICAL LIGHTING PLAN <br />SCALE: 1/4" = V-0" <br />OKEYED NOTES: <br />1. PROVIDE NEW 7—DAY, ASTRONOMICAL TIMECLOCK, PROVIDE <br />ADDITIONAL CONTACTOR AS REQUIRED FOR NEW LIGHTING <br />CIRCUITS. <br />2. PROVIDE LIGHTING CONTACTOR OVERRIDE SWITCH. <br />COORDINATE FINAL LOCATION WITH OWNER AND ARCHITECT. <br />3. CONNECT LIGHTING TO GFI RECEPTACLE IN THIS SPACE. <br />WIRE LIGHTING LINE SIDE (AHEAD) OF RECEPTACLE. <br />4. PROVIDE CEILING MOUNTED SPEAKER BACK BOX. PROVIDE <br />RATED SPEAKER WIRE AND TIE INTO AUDIO SYSTEM. <br />0 *�# <br />MCVEIGH GUM <br />ENGINEERING INC <br />Atlanta • Charlotte • Jacksonville Raleigh <br />www.McVeighMangum.com <br />1955 Lake Park Drive SE, Suite 325 <br />Smyrna, Georgia 30080 <br />Ph: (678) 213-1616 <br />email: mail@McVeighMangum.com <br />PEF005182 <br />Eng. of Record:LADD D. MARKS, P.E. License No.:58264 <br />R A N D A L L <br />0 <br />A U L S 0 N <br />r C i t 0 C t S <br />Roswell Mill <br />05-A Mill Streets Suite 200 <br />Roswell, Georgia 30975 <br />t 770.650.1550 f 770.650.7559 <br />e-mail architects@randallpaulson.com <br />'/ 1 In t' r 10. <br />These plans and specifications are the property of Randall -Paulson Architects, <br />Incorporated. These documents may not he copied, reproduced, used or <br />implemented in any way, in part grin whole, without the written consent of <br />Randall -Paulson Architects, Incorporated. All common law rights of copyright are <br />hereby specifically reserved. <br />TENANT <br />BUILD -OUT <br />at <br />ZEPHYRHILLS <br />for <br />U.S. HIGHWAY 301 & PRETTY <br />POND ROAD, <br />ZEPHYRHILLS, FLORIDA 33541 <br />Print Record <br />PERMIT <br />Revisions <br />Date Project No. <br />14 JUNE 2021 2021217.00 <br />Sheet Title <br />LIGHTING PLAN <br />Sheet No. <br />Eml 00 <br />Released for Construction <br />❑ Not Released for Construction <br />