PLUMBING FIXTURE DEMAND TABULATION
<br />Project Name:SAGE DENTAL BUILDING TYPE: NEW
<br />Project No.: 212028 PREDOMINANTLY: FLUSH TANK
<br />Date: ;6/7/20211 16:30
<br />FIXTURE
<br />DESCRIPTION
<br />OCCUPANCY
<br />QTY.
<br />DRAINAGE
<br />SUB-
<br />LOAD VALUES IN WATER (EACH)
<br />LOAD VALUES IN WATER (TOTAL)
<br />Remarks
<br />FIXTURE
<br />TOTAL
<br />SUPPLY FIXTURE
<br />UNITS (WSFU)
<br />SUPPLY
<br />FIXTURE UNITS (WSFU)
<br />UNITS
<br />COLD
<br />HOT
<br />TOTAL
<br />COLD
<br />HOT
<br />TOTAL
<br />WC-1A
<br />WATER CLOSET
<br />PUBLIC
<br />2
<br />4
<br />8
<br />5
<br />0
<br />10
<br />10
<br />0
<br />20
<br />L-1
<br />LAVATORY
<br />PUBLIC
<br />2
<br />1
<br />2
<br />1.5
<br />1.5
<br />2
<br />3
<br />3
<br />4
<br />S-1
<br />SINK
<br />PUBLIC
<br />1
<br />1
<br />1
<br />1.5
<br />1.5
<br />2
<br />1.5
<br />1.5
<br />2
<br />S-2
<br />SINK
<br />PUBLIC
<br />1
<br />1
<br />1
<br />1.5
<br />1.5
<br />2
<br />1.5
<br />1.5
<br />2
<br />S-3
<br />SINK
<br />PUBLIC
<br />4
<br />1
<br />4
<br />1.5
<br />1.5
<br />2
<br />6
<br />6
<br />8
<br />S4
<br />SINK
<br />PUBLIC
<br />3
<br />1
<br />3
<br />1.5
<br />1.5
<br />2
<br />4.5
<br />4.5
<br />6
<br />MS-1
<br />MOP SINK
<br />PUBLIC
<br />1
<br />1 3
<br />3
<br />1.5
<br />1.5
<br />2
<br />1.5
<br />0
<br />2
<br />TOTALS
<br />DFU = DRAINAGE FIXTURE UNITS
<br />WSFU = WATER SUPPLY FIXTURE UNITS
<br />22 DFU
<br />EIGHTH INCH SLOPE PER FOOT
<br />3 DIAMETER OF PIPE (INCHES)
<br />28
<br />16.5
<br />44
<br />22.6
<br />18.2
<br />27.4
<br />1.5
<br />1.5
<br />2
<br />WSFU
<br />GPM
<br />INCHES REQ'D.
<br />PLUMBING FIXTURE SCHEDULE
<br />EQUIP.
<br />NO.
<br />MANUFACTURER
<br />MODEL NO.
<br />DESCRIPTION
<br />CW
<br />HW
<br />WASTE
<br />VENT
<br />NOTES
<br />EWC-1
<br />ELKAY
<br />VRC8(FR)S
<br />ELECTRIC WATER COOLER W/BASINS (BARRIER FREE)
<br />1/2"
<br />-
<br />1 1/2"
<br />1 1/2"
<br />8.0 GPH CAPACITY, 370 RATED WATTS, 5.0 F.L.A., 120-1-60.
<br />VITREOUS CHINA WALL -HUNG LAVATORY (HANDICAP)
<br />FAUCET - KOHLER K-394-4, LEVER HANDLES, 0.5 GPM
<br />L-1
<br />KOHLER
<br />K-5027-8
<br />TRAP - 1 1/4" CAST BRASS WITH C.O. PLUG SUPPLY - 3/8" ANGLE -TYPE WITH STOPS
<br />1/2"
<br />1/2"
<br />1 1/2"
<br />1 1/2"
<br />PROVIDE OFFSET TAILPIECE INSULATE TRAP
<br />OUTLET & HW SUPPLY TO MEET A.D.A.
<br />MS-1
<br />FIAT
<br />TSB-500
<br />32"x32" MOLDED STONE FLOOR MOUNTED MOP BASIN W/STAINLESS STEEL GUARDS
<br />1/2"
<br />1/2"
<br />3"
<br />2"
<br />FAUCET - FIAT 830 AA W/VACUUM BREAKER, INTEGRAL STOPS, ADJ. WALL BRACE, PAIL HOOK & 3/4" HOSE TREAD ON SPOUT
<br />SINGLE -COMPARTMENT, 4" CENTER 2-HOLE, 18-GAUGE 304 STAINLESS STEEL SELF -RIMMING, FULLY COATED UNDERSIDE;
<br />S-1
<br />KOHLER
<br />K3894-NA
<br />FAUCET WITH SWIVEL GOOSENECK SPOUT WITH WRIST BLADE HANDLES. INSTALL PER ADA REQUIREMENTS. PROVIDE
<br />1/2"
<br />1/2"
<br />1 1/2"
<br />1 1/2"
<br />CHROME -PLATED P-TRAP, ANGLE STOPS, AND BRAIDED FLEXIBLE SUPPLY HOSES.
<br />DAYTON
<br />SINGLE COMPARTMENT, 25X22 20-GAUGE 304 STAINLESS STEEL SELF -RIMMING, FULLY COATED UNDERSIDE; PROVIDE CHROME
<br />S-2
<br />ELKAY
<br />DPM-SR-12722P
<br />PLATED LOOSE KEY ANGLE STOP, ESCUTCHEON, P-TRAP AND SUPPLIES. INSTALLED PER ADA ACCESSIBILITY; TRUEBRO LAV
<br />1/2"
<br />1/2"
<br />1 1/2"
<br />1 1/2"
<br />D 4-HOLE
<br />GUARD UNDERSINK PROTECTIVE COVERS FOR P-TRAP AND ANGLE VALVE ASSEMBLIES MODEL 102. LKAD18 GRID DRAIN WITH
<br />(SIDE -SPRAY)
<br />OFFSET TRAP.
<br />S-3
<br />DENTAL SINK
<br />FIXTURE BY
<br />OWNER
<br />DENTAL STATION WITH INTEGRAL SINK. COORDINATE WITH ARCHITECTUAL PLANS AND DETAIL.
<br />1/2"
<br />1/2"
<br />1 1/2"
<br />1 1/2"
<br />DAYTON
<br />#K-11515
<br />SINGLE COMPARTMENT, 15X15, 20-GAUGE 304 STAINLESS STEEL SELF -RIMMING, FULLY COATED UNDERSIDE; PROVIDE CHROME
<br />S-4
<br />ELKAY
<br />NSTAINLESS
<br />PLATED LOOSE KEY ANGLE STOP, ESCUTCHEON, P-TRAP AND SUPPLIES. INSTALLED PER ADA ACCESSIBILITY; TRUEBRO LAV
<br />1/2"
<br />1/2"
<br />1 1/2"
<br />1 1/2"
<br />STEEL SINK
<br />GUARD UNDERSINK PROTECTIVE COVERS FOR P-TRAP AND ANGLE VALVE ASSEMBLIES MODEL 102. FULL SIZE GRID DRAIN
<br />BOWL: (ADA) VITREOUS CHINA, FLOOR MOUNTED, TOP SPUD, FULLY GLAZED TRAP WAY, SIPHON JET ACTION FLUSH AND
<br />WCAA
<br />KOHLER
<br />K-4405
<br />ELONGATED BOWL. VALVE: MANUAL BRONZE BODY, ACCESSORIES SHALL INCLUDE VACUUM BREAKER, ANGLE STOP, CHECK
<br />1/2"
<br />-
<br />4"
<br />2"
<br />VALVE AND ESCUTCHEON. SEAT: EXTRA HEAVY WEGIHT PLASTIC, OPEN FRONT LESS COVERINTEGRALLY MOULDED BUMPERSM
<br />BOLT CAPS AND STAINLESS STEEL HINGE.
<br />NOTE:
<br />1. PROVIDE MIXING VALVE AT EYEWASH EQUAL TO BRADLEY S59-4000A
<br />WATER HEATER SCHEDULE
<br />TEMPERATU
<br />0
<br />ELECTRIC
<br />POWER
<br />LOCATION
<br />MINIMUM STORAGE CAPACITY
<br />MINIMUM RECOVERY CAPACITY
<br />SUPPLY
<br />(V/O/HZ)
<br />TYPE MARK
<br />DISC.
<br />ELEMENT
<br />Manufacturer
<br />(GAL)
<br />(GPH)
<br />INPUT (kW)
<br />NOTES
<br />EWH-1
<br />AO SMITH
<br />MECHANICAL
<br />30
<br />23
<br />140
<br />4.5
<br />208-1-60
<br />1
<br />NOTE:
<br />1. PROVIDE WATER CIRCULATION PUMP EQUAL TO TACO MODEL 006B, 3 GPM@ 9FT/HD.
<br />PIPE MATERIAL LIST:
<br />1. SANITARY, WASTE, AND VENT PIPING: FITTINGS SHALL BE LONG RADIUS FITTINGS, EXCEPT FITTINGS IN VENT PIPING
<br />MAY BE SHORT RADIUS FITTINGS. CONTRACTOR OPTIONS:
<br />A. BELOW GRADE: CAST IRON, ASTM A74, STANDARD, SINGLE HUB, COATED.
<br />B. ABOVE GRADE: CAST IRON, NO HUB, CISPE STANDARD 301.
<br />C. ABOVE AND BELOW GRADE: PVC, SCHEDULE 40, MEETING ASTM D1785.
<br />2. DOMESTIC WATER PIPING:
<br />A. BELOW GRADE: TYPE K, COATED WITH COAL TAR SHELLAC.
<br />B. ABOVE GRADE: TYPE L.
<br />C. ABOVE AND BELOW GRADE UP TO 1 1/4": CPVC MEETING ASTM D2846.
<br />D. ABOVE AND BELOW GRADE 1 1/2" AND LARGER: CPVC SCHEDULE 80 MEETING ASTM F441 AND ASTM F439.
<br />E. EXTERIOR DOMESTIC WATER PIPING: PVC, SCHEDULE 40 MEETING ASTM D1785.
<br />3. COMPRESSED -AIR PIPING:
<br />A. PIPING 3" AND SMALLER: TYPE L, COPPER MEDICAL GAS TUBE; WROUGHT -COPPER FITTINGS; AND BRAZED JOINTS
<br />B. PIPING LARGER THAN 3": TYPE K, COPPER TUBE; WROUGHT -COPPER FITTINGS; AND BRAZED JOINTS.
<br />4. DENTAL VACUUM PIPING:
<br />A. ASTM B 88, TYPE M, SEAMLESS, DRAWN TEMPER COPPER WATER TUBE, WROUGHT -COPPER FITTINGS, AND
<br />BRAZED JOINTS.
<br />PLUMBING TESTING AND DISINFECTING:
<br />1. TESTING:
<br />A. SOIL, WASTE, VENT SYSTEM:
<br />1. TEMPORARILY PLUG ALL OUTLETS.
<br />2. FILL LINES WITH WATER TO THE ROOF LEVEL.
<br />3, ALLOW TO REMAIN FULL FOR 24 HOURS.
<br />B. WATER SYSTEM:
<br />1. TEST AT 150 PERCENT OF DESIGN PRESSURE, BUT NOT LESS THAN 100 PSIG.
<br />2. ALLOW PRESSURE TO REMAIN ON LINE FOR 24 HOURS.
<br />C. REPAIR ALL DETECTABLE LEAKS IN PIPING SYSTEMS
<br />2. DISINFECTION OF DOMESTIC WATER SYSTEM:
<br />A. DISINFECT DOMESTIC WATER SYSTEM AFTER APPROVAL OF TEST RESULTS AND PIPING INSTALLATION BY
<br />BUILDING OFFICIAL.
<br />B. PRIOR TO SUBSTANTIAL COMPLETION STERILIZE PIPING SYSTEM IN ACCORDANCE WITH LOCAL PLUMBING CODE
<br />REQUIREMENTS.
<br />C. DELIVER CERTIFICATION TO BUILDING OFFICIAL.
<br />PLUMBING GENERAL NOTES
<br />1. IN THE PREPARATION OF THESE PLANS, THE ENGINEER HAS USED CERTAIN
<br />ABBREVIATIONS, CONVENTIONS, AND SYMBOLS, THE MEANING OF WHICH ARE
<br />ILLUSTRATED AND EXPLAINED WITHIN THE LEGEND.
<br />2. PLANS ARE DIAGRAMMATIC ONLY. THEY ARE INTENDED TO INDICATE CAPACITY,
<br />SIZE, LOCATION, DIRECTION AND GENERAL ARRANGEMENT, BUT NOT EXACT
<br />DETAILS OF CONSTRUCTION. THE FACT THAT ONLY CERTAIN FEATURES OF THE
<br />INSTALLATION ARE INDICATED MUST NOT BE TAKEN TO MEAN THAT OTHER
<br />FEATURES WILL NOT BE REQUIRED.
<br />3. COORDINATE WITH THE OTHER TRADES TO ENSURE THAT EACH TRADE SHALL
<br />HAVE SUFFICIENT SPACE TO INSTALL THEIR EQUIPMENT (DUCTWORK, PIPING,
<br />ELECTRICAL WORK, ETC.).
<br />4. ONCE THE PIPING HAS ENTERED EACH UNIT FROM BELOW THE FLOOR SLAB,
<br />PIPING SHALL BE RUN ABOVE THE CEILING IN EACH UNIT UNLESS NOTED OR
<br />INDICATED OTHERWISE.
<br />5. VERIFY ALL DIMENSIONS FROM ARCHITECTURAL PLANS AND FIELD DIMENSIONS.
<br />6. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN.
<br />7. PROVIDE STOP OR ANGLE VALVES ON EACH WATER CONNECTION TO EACH
<br />PLUMBING FIXTURE.
<br />8. PROVIDE ALL STRUCTURAL MEMBERS, SUPPORT BRACKETS, FLASHING,
<br />HARDWARE, ETC. REQUIRED TO INSTALL A COMPLETE SYSTEM.
<br />9. PROVIDE CHROME PLATED ESCUTCHEON PLATES AT ALL EXPOSED WALL
<br />PENETRATIONS AND CEILING PENETRATIONS.
<br />10. PROVIDE CLEANOUTS ON SANITARY LINES AND CONDENSATE DRAIN LINES AS
<br />REQUIRED BY CODE.
<br />11. PROVIDE ACCESS PANELS FOR ALL SHUT-OFF VALVES LOCATED ABOVE
<br />GYPSUM BOARD CEILINGS. COORDINATE WITH GENERAL CONTRACTOR.
<br />ABBREVIATIONS
<br />A/C
<br />ABOVE CEILING
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />AFG
<br />ABOVE FINISHED GRADE
<br />BFF
<br />BELOW FINISHED FLOOR
<br />BFG
<br />BELOW FINISHED GRADE
<br />BTU
<br />BRITISH THERMAL UNIT
<br />CO
<br />CLEANOUT
<br />CONN
<br />CONNECTION
<br />CW
<br />COLD WATER
<br />DN
<br />DOWN
<br />DW
<br />DOMESTIC WATER
<br />DWV
<br />DRAIN WASTE VENT
<br />DFU
<br />DRAINAGE FIXTURE UNIT
<br />ED
<br />EQUIPMENT DRAIN
<br />EX
<br />EXISTING
<br />FU
<br />FIXTURE UNIT
<br />FL
<br />FLOOR
<br />FCO
<br />FLOOR CLEANOUT
<br />GPM
<br />GALLONS PER MINUTE
<br />GC
<br />GENERAL CONTRACTOR
<br />GCO
<br />GRADE CLEANOUT
<br />GW
<br />GREASE WASTE
<br />HW
<br />HOT WATER
<br />HWR
<br />HOT WATER RETURN
<br />IE
<br />INVERT ELEVATION
<br />IN
<br />INCHES
<br />MIN
<br />MINIMUM
<br />OST
<br />OVERFLOW STORM
<br />PC
<br />PLUMBING CONTRACTOR
<br />SAN or S
<br />SANITARY
<br />ST
<br />STORM
<br />V
<br />VENT
<br />VTR
<br />VENT TO ROOF
<br />WCO
<br />WALL CLEANOUT
<br />W
<br />WASTE
<br />WTR
<br />WATER
<br />WSFU
<br />WATER SUPPLY FIXTURE UNIT
<br />W/
<br />WITH
<br />W/O
<br />WITHOUT
<br />GENERAL SYMBOLS
<br />PLAN OR DETAIL NO.
<br />SHEET NUMBER
<br />OKEYED
<br />NOTE TO PLAN
<br />QREVISION
<br />NUMBER
<br />N
<br />NORTH ARROW
<br />FIRE PROTECTION GENERAL NOTES
<br />PLUMBING SYMBOL LEGEND
<br />- - -
<br />COLD WATER PIPE
<br />- - - - - - - -
<br />HOT WATER PIPE
<br />- -
<br />HOT WATER RETURN PIPE
<br />- -
<br />EXISTING COLD WATER PIPE
<br />- - -
<br />EXISTING HOT WATER PIPE
<br />- -
<br />EXISTING HOT WATER RETURN PIPE
<br />FIRE
<br />-
<br />GREASE WASTE
<br />SOIL OR WASTE PIPE
<br />EXISTING SOIL OR WASTE PIPE
<br />STORM
<br />STORM SECONDARY
<br />- - - - - - -
<br />VENT PIPE
<br />- - -
<br />EXISTING VENT PIPE
<br />CHILLED WATER RETURN PIPE
<br />CHILLED WATER SUPPLY PIPE
<br />CONDENSER WATER PIPE
<br />COOLING WATER RETURN PIPE
<br />COOLING WATER SUPPLY PIPE
<br />O
<br />TURNED UP
<br />TURNED DOWN
<br />TEE, OUTLET DOWN
<br />tE
<br />TEE, OUTLET UP
<br />T&P
<br />TEMPERATURE AND PRESSURE
<br />RELIEF DRAIN PIPING
<br />ED
<br />EMERGENCY DRAIN PAN PIPING
<br />GATE VALVE
<br />PRESSURE RELIEF VALVE
<br />BALL VALVE
<br />FIXTURE
<br />PLUMBING FIXTURE
<br />DESIGNATION (UNDER LINED)
<br />CONNECT TO EXISTING
<br />DISCONNECT FROM EXISTING
<br />-
<br />DENTAL VACUUM
<br />- - - - - - -
<br />DENTAL COMPRESSED AIR
<br />___ - ___
<br />FILTERED WATER
<br />1. FIRE PROTECTION WORK SHALL BE DESIGNED, INSTALLED, AND TESTED IN ACCORDANCE WITH NFPA 13, LATEST EDITION OR AS OTHERWISE
<br />ADOPTED BY THE AUTHORITY HAVING JURISDICTION.
<br />2. INCLUDE ANY INCIDENTAL APPARATUS, APPLIANCES, MATERIAL, LABOR AND SERVICES NECESSARY TO MAKE NEW WORK COMPLETE IN ALL
<br />RESPECTS AND FULLY READY FOR OPERATION.
<br />3. PLANS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL REQUIRED SYSTEM COMPONENTS. MAKE SUCH OFFSETS AN
<br />DEVIATIONS FROM WORK SHOWN ON THE DRAWINGS, AS MAY BE NECESSARY TO ACCOMMODATE THE ACTUAL SPACE CONDITIONS.
<br />4. INSTALLER SHALL COORDINATE WITH ALL PLUMBING, HVAC, ELECTRICAL AND GENERAL WORK SO AS NOT TO CONFLICT IN LOCATION WITH
<br />OTHER TRADES UNDER THIS CONTRACT OR THAT MAY BE EXISTING. CONTRACTOR SHALL ADJUST PIPE ROUTE AS NECESSARY TO AVOID
<br />CONFLICTS WITH DUCTWORK, EQUIPMENT, LIGHTING, ETC.
<br />5. INSTALLER SHALL NOT NOT OR MODIFY IN ANY WAY ANY STRUCTURAL MEMBER WITHOUT FIRST SECURING WRITTEN APPROVAL FROM THE
<br />ARCHITECT.
<br />6. PIPE SIZES, ROUTING, AND SPECIFIC CONFIGURATION OF SYSTEMS ARE REQUIRED TO BE HYDRAULICALLY CALCULATED AND SHALL BE
<br />SUBMITTED TO THIS ENGINEER FOR REVIEW.
<br />7. CONTRACTOR SHALL ARRANGE FOR, OBTAIN, AND BEAR THE COST OF NECESSARY PERMITS, BONDS, AND FEES.
<br />8. ALL MATERIALS SHALL BE U.L. LISTED AND BEAR THE U.L. LABEL.
<br />9. CONDITIONS SHOWN AS EXISTING (LOCATIONS, MATERIALS, ELEVATIONS, SIZES, ETC.) ARE BASED ON AVAILABLE EXISTING DATA AND
<br />SHOULD BE INTERPRETED TO BE APPROXIMATE. CONTRACTOR SHALL VERIFY CONDITIONS IN THE FIELD. EXISTING CONDITIONS FOUND TO
<br />DEVIATE FROM THOSE SHOWN SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY UPON DISCOVERY.
<br />10. PENETRATIONS THROUGH FIRE -RATED ASSEMBLIES, PENETRATIONS FOR PIPES, CONDUITS, OR OTHER PURPOSES THROUGH ASSEMBLIES
<br />(FLOORS, ROOFS, WALLS, PARTITIONS, ETC.) WITH A REQUIRED FIRE STOP MATERIAL FIRE SHALL BE U.L. LISTED AND INSTALLED IN STRICT
<br />ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS TO MEET OR EXCEED THE FIRE RATING OF THE PENETRATED ASSEMBLY.
<br />11. BEFORE SHUTTING OFF ANY SECTION OF THE FIRE PROTECTION SYSTEM TO MAKE ADJUSTMENTS OR ADDITIONAL CONNECTION,
<br />COORDINATE WITH THE OWNER AND NOTIFY THE AUTHORITY HAVING JURISDICTION. PLAN THE WORK CAREFULLY AND ASSEMBLE ALL
<br />MATERIALS TO ENABLE COMPLETION IN THE SHORTEST POSSIBLE TIME. WORK SHALL BE USED TO COMPLETION WITHOUT INTERRUPTION,
<br />AND PROTECTION SHALL BE RESTORED AS PROMPTLY AS POSSIBLE.
<br />12. PROVIDE DEFLECTORS ON ELECTRICAL EQUIPMENT TO PREVENT WETTING PANELS. SPRINKLER PIPING SHALL NOT BE INSTALLED DIRECTLY
<br />ABOVE ELECTRICAL PANELS, TRANSFORMERS, ETC.
<br />13. PROVIDE FLUSHING CONNECTION AT END OF SPRINKLER SYSTEM WHERE LAY -IN CEILING OCCURS. ALL SPRINKLER PIPING THAT REQUIRES
<br />CHANGE IN ELEVATION DUE TO COORDINATION OF ROUTING OF PIPING SHALL HAVE FLUSH CONNECTION AL ALL LOWER ELEVATIONS. THE
<br />SPRINKLER SYSTEM SHALL BE INSTALLED AS COMPLETELY DRAINABLE.
<br />14. WHEN CONFLICTS OCCUR IN THE SPECIFICATIONS OR DRAWINGS, THE ITEM(S) OF GREATER QUANTITY OR HIGHER COST SHALL BE
<br />PROVIDED.
<br />15. SPRINKLER HEADS IN MECHANICAL ROOMS SHALL BE COORDINATED WITH THE EQUIPMENT AND DUCTWORK. THE SPRINKLER CONTRACTOR
<br />SHALL COORDINATE HIS SHOP DRAWINGS WITH THOSE OF THE HVAC CONTRACTOR AND PROVIDE HEADS BETWEEN EQUIPMENT AND UNDER
<br />DUCTWORK AS REQUIRED BY CODE. ADDITIONAL SPRINKLERS SHALL BE PROVIDED UNDER ALL DUCTS AND OBSTRUCTIONS GREATER THAN 4
<br />FEET IN WIDTH, AND AS OTHERWISE REQUIRED BY NFPA 13.
<br />16. THE INSTALLED SHALL VISIT THE PROJECT SITE AND INSPECT ALL EXISTING CONDITIONS AFFECTING THE WORK. SUBMISSION OF HIS
<br />PROPOSAL SHALL BE CONSTRUED AS INDICATING SUCH KNOWLEDGE. NO ADDITIONAL PAYMENT WILL BE MADE ON CLAIMS THAT ARISE FROM
<br />THE CONTRACTOR'S FAILURE TO COMPLY WITH THIS REQUIREMENT.
<br />17. VERIFY THE EXACT LOCATION OF THE FIRE PROTECTION PIPING, FROM THE ACTUAL JOB SITE. ALL NEW PIPES ARE TO BE ROUTED TO AND/OR
<br />FROM VERIFIED LOCATIONS. TAPS, WHEN NOT PROVIDED BY THE PREVIOUS INSTALLER, SHALL BE PROVIDED BY THIS INSTALLER.
<br />18. PROVIDE AND MAINTAIN TEMPORARY CONNECTIONS TO KEEP EXISTING FIRE PROTECTION SYSTEM IN SERVICE. ANY SERVICE INTERRUPTION
<br />SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE.
<br />19. UPON COMPLETION OF THE WORK UNDER THIS CONTRACT, THE CONTRACTOR SHALL REMOVE ALL TOOLS, APPLIANCES, SURPLUS MATERIAL,
<br />AND SCRAP. ALL IDENTIFIED EXISTING EQUIPMENT TO BE REMOVED SHALL BE TURNED OVER TO THE OWNER.
<br />o-i/ ;Z
<br />0.i� STATE OF ; W ZZ
<br />'ONAL
<br />MicVEIGH&MANGUM
<br />ENGINEERING INC
<br />Atlanta - Charlotte • lacksonville Raleigh
<br />www.McVeighMangum com
<br />1955 Lake Park Drive SE, Suite 325
<br />Smyrna; Georgia 30080
<br />Ph (678) 213-4616
<br />email: mail@McVeighMangum.com
<br />PEF005182
<br />Eng. of Record:KENNETH GONZALEZ License No.:61015
<br />!R
<br />A
<br />N
<br />D
<br />A
<br />L
<br />L
<br />la r c h i t e c t s
<br />Roswell Mill
<br />85-A Mill Street, Suite 200
<br />Roswell, Georgia 39075
<br />t 710.650.7558 f 710.650.1559
<br />e-mail architects@?randalipaulson.com
<br />These plans and specifications are no property of Randall•Paulson Architects,
<br />Incorporated. These documents may not be copied, reproduced, used or
<br />implemented in any way, in part of in whole, Mtheutthe Written Consent of
<br />Randall-Paulsan Architects, Incorporated. All common law rights of copyright are
<br />hereby specifically reserved.
<br />TENANT
<br />BUILD -OUT
<br />at
<br />ZEPHYRHILLS
<br />for
<br />U.S. HIGHWAY 301 & PRETTY
<br />POND ROAD,
<br />ZEPHYRHILLS, FLORIDA 33541
<br />Print Record
<br />Revisions
<br />Date Project No.
<br />14 JUNE 2021 2021217.00
<br />Sheet Title
<br />NOTES, LEGENDS, & SYMBOLS
<br />- - -
<br />� r :Ilr. ., u _ ,. I _.� . I
<br />-;- �, . ..�. �� ;i:•.r.l, -.l ,:�rir�ui 71 ��1-�ILC71�1� T%1 .