Laserfiche WebLink
EXISTING WALL <br />ALIGN <br />g:• B2 <br />" <br />to <br />3 <br />O <br />O <br />NEW CMU W/ #5 BARS @ 32" <br />FINISH <br />O <br />', ." . <br />, <br />O <br />8 <br />1 <br />1 <br />n: <br />OC, MAX (CENTERED IN CELL) -DOWEL <br />N <br />fv <br />1 <br />1 <br />n <br />INTO EXISTING CMU <br />STOR. <br />�4�01 <br />• <br />• <br />t <br />tINTEUGROUTED BLOCKS <br />_ <br />�. �. ;I � <br />1 <br />A. � :< ,� ; <br />126 <br />�/ <br />F1 F1 <br />... <br />-„ <br />USING HILTI HY270 ADHESIVE <br />€ yy; <br />< <br />._.. <br />_ <br />115 <br />� <br />• STORAGE <br />1 G4 <br />I <br />1r� <br />• ii �, <br />� � � � '' ti ' <br />{ � s �e c is ^ ./.f'' <br />(6 MIN EMBED) <br />1 1 <br />• RATED DOOR <br />R <br />• <br />EXT. DOOR TO E <br />B <br />1 <br />125 <br />45MIN.WITH <br />y < <br />LOCKED SHUT <br />OPENBAY1 <br />< OPEN BAY 2 <br />BIO2 <br />1 CLOSER AND <br />SMOKE GASKET <br />1 OPEN BAY 3 OPEN BAY 4 <br />j < <br />``:: `' 123 122 <br />PERMANENTLY <br />M <br />Sim <br />128 <br />_ —_ _— —_ <br />127 <br />403 <br />• <br />1 <br />F1 <br />1 <br />-- -- -- -- <br />NEW CMU INFILL @ EXISTING <br />-101) <br />• 113 <br />• <br />101E <br />DOOR LOCATION <br />116) <br />114 <br />`•�•�•• •�•�' •�•�• <br />, <br />GROUT ALL VERT CELLS <br />CONTAINING VERT REINFORCING <br />5 <br />1 <br />6 <br />FULL HEIGHT OF WALL - USE 2,000 <br />103E A-102 <br />:Q <br />PSI SELF CONSOLIDATIING GROUT <br />6112" --9'- T0-1/2" — - — - 10' - 81/2" "' <br />5' - 0" 1' - 9" 4' -11 1/2" — — — 19' - 9" A-102 <br />0 <br />W/ HI LIFT GROUT <br />CLEAR, TYP. <br />�' <br />= <br />NEW 5/8" GYP.BD OVER <br />ALIGN <br />ALIGN <br />_ <br />FURRING CHANNEL. <br />I <br />SEE FLOOR PLAN FOR <br />2 <br />1 <br />ri <br />TYPE OF FURRED WALL <br />OPEN BAY OPEN BAY 7 <br />2 115 11 & <br />`\ o <br />N <br />" I <br />1 OPEN BAY 5 OPEN BAY 6 <br />120 / x. 12 � <br />n o I ., ` <br />NEW SELF -FURRING LATH, CEMENT <br />CORRIDOR <br />2 <br />PLASTER BASECOAT AND FINISH COAT- <br />STERILIZATION <br />118 ` <br />d » <br />;... <br />PAINT WALL, TOP TO BOTTOM, END OR <br />2 <br />I <br />/ <br />TO NEXT DOWNSPOUT, OR OTHER VISUAL <br />_? <br />117 <br />BREAK POINT FOR SMOOTH SEAMLESS <br />- <br />AIR VALVE, SEE <br />I PANO <br />K,. <br />P F VERIFY MATCH <br />REPAIR. FIELD ERI Y COLOR TO C <br />P <br />J <br />:.. <br />2 <br />119 <br />-403 3 I <br />r' •'g� <br />I , <br />` <br />EXISTING. <br />• // <br />f k i.. J./ <br />9 -401 <br />;f�,.y<l y/i <br />A.h` �. <br />NEW CMU W/ #5 BARS @ 32 <br />O <br />O <br />O <br />O <br />4 <br />IN CELL) <br />OC, MAX (CENTERED LL - <br />' <br />I <br />— — — <br />-:: <br />INTO EXISTING CMU <br />; <br />........ ; <br />1 <br />i <br />2 <br />1 <br />A-005 <br />LINTEUGROUTED BLOCKS <br />USING HILTI HY270 ADHESIVE <br />a <br />— <br />(6" MIN EMBED) <br />- <br />EXISTING CONCRETE SLAB <br />t, <br />i <br />. <br />FIXED <br />WINDOW <br />0. <br />Z\ <br />I <br />, � �� �. <br />FINISH FLOOR <br />- EXISTING FOUNDATION <br />Ll <br />SECTION DETAIL @ INFILL <br />1" = 1'-0" <br />1 OVERALL FLOOR PLAN NoRTn <br />A-101 1 /4" = 1'-0" /I <br />PARTITION LEGEND <br />POCHE WALL INDICATES EXISTING TO REMAIN <br />C _ _ ] DASH LINE INDICATED ITEMS TO BE REMOVED <br />LINE INDICATES NEW PARTITION <br />HATCH INDICATES AREAS NOT IN SCOPE <br />PARTITION PLAN GENERAL NOTES: <br />1. REFER TO PROJECT GENERAL NOTES FOR FURTHER INFORMATION. <br />2. SEE ENGINEERING DRAWINGS FOR MORE INFORMATION. COORDINATE PARTITION LAYOUT WITH <br />MECHANICAL, ELECTRICAL, DATA, SPRINKLER AND PLUMBING WORK. NOTIFY ARCHITECT TO RESOLVE <br />CONFLICTS WITH ANY DESIGN ELEMENTS. <br />3. PROVIDE TOILET ROOM SIGNS COMPLYING WITH THE REQUIREMENTS OF THE PREVAILING FLORIDA <br />HANDICAP ACCESSIBILITY CODE. <br />4. PROVIDE AUDIBLE/ VISUAL SIGNAL APPLIANCES COMPLYING WITH THE REQUIREMENTS OF THE <br />PREVAILING NFPA 72 AND FLORIDA ACCESSIBILITY CODES, IF REQUIRED BY LOCAL CODES. <br />5. CONTRACTOR TO PERMANENTLY IDENTIFY ALL FIRE -RATED WALLS (AND CORRESPONDING FIRE - <br />RESISTANCE RATING) INCLUDING FIRE BARRIER WALLS, SMOKE BARRIER WALLS, FIRE PARTITIONS, FIRE <br />WALLS AND SHAFT ENCLOSURES EITHER BY INSTALLING SIGNS OR BY STENCILING IN CONCEALED SPACES <br />THE FOLLOWING () HOUR FIRE AND SMOKE BARRIER. PROTECT ALL OPENINGS WITH FIRESTOPPING <br />MATERIAL. IDENTIFICATION SHALL BE SPACED NO MORE THAN (12) TWELVE FEET ON CENTER WITH A <br />MINIMUM LETTER SIZE OF (2) TWO INCHES IN HEIGHT IN CONTRASTING BACKGROUND. <br />6. ALL INSULATING MATERIALS SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE - <br />DEVELOPED INDEX OF NOT MORE THAN 450 AS DETERMINED IN ACCORDANCE WITH PREVAILING ASTM AND <br />SBC. <br />7. ALL NEW WALLS EXCEEDING 19-0" IN UNBRACED LENGTH SHALL BE BRACED WITH A HORIZONTAL STUD <br />CONNECTING THE TOP OF THE WALL WITH THE ADJACENT PERPENDICULAR WALL. THE HORIZONTAL <br />BRACING SHALL START 5'-0" FROM THE CORNER OF THE INTERSECTION OF THE TWO WALLS CREATING A 45 <br />DEGREE ANGLE. THE HORIZONTAL BRACING SHALL BE THE SAME STUD SIZE AND GAUGE AS THE WALL STUD. <br />8. ALL MILLWORK SHALL BE FABRICATED AND INSTALLED IN STRICT ACCORDANCE WITH THE PREVAILING <br />EDITIONS OF ALL APPLICABLE STATE AND LOCAL CODES. CONTRACTOR TO MEET THE REQUIREMENTS OF <br />THE PREVAILING ACCESSIBILITY CODES AS THEY PERTAIN TO MILLWORK OF ANY KIND. <br />9. THE CONTRACTOR SHALL FIELD VERIFY ALL MILLWORK DIMENSIONS PRIOR TO FABRICATION. <br />10. WRAP AND INSULATE ALL PLUMBING PIPES TO MEET CODE. <br />11. DOORS INDICATED ON PARTITION PLAN AS "EX" ARE EXISTING <br />12. CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS PER CODE, OR 1/3000 SF, OR AS LOCATED ON PLANS <br />MOUNTED @ 48" A.F.F. MAXIMUM TO TOP OF EXTINGUISHER HANDLE. SIZE OF FIRE EXTINGUISHERS SHALL BE <br />MIN. AS INDICATED ON DRAWINGS OR REQUIRED BY FIRE MARSHAL. <br />1 <br />J <br />0-15-2021 <br />ffuswell bill <br />85-A fill Street, Suite 200 <br />Roswell, Georgia 30075 <br />t 710.6503550 f 770.650.1559 <br />e-mail architect@?randallpoulson.com <br />I <br />These plans and specdications are An property of RandalVaulson Architects, <br />Incorporated. Those documents may not he copied, rapreduced, used or <br />implemented in any war, in part or in whole, without the written consent of <br />RmndalRoulsoo Archtects, Incorporated. AR common low fights of copyright am <br />hereby specifically roseraed. <br />FLORIDA BIG ISTRATION#AA0003296 <br />TENANT <br />BUILD -OUT <br />at <br />ZEPHYRHILLS <br />for <br />U.S. HIGHWAY 301 & PRETTY <br />POND ROAD, <br />ZEPHYRHILLS, FLORIDA 33541 <br />Print Record <br />Revisions <br />Date <br />14 JUNE 2021 <br />Project No. <br />2021217.00 <br />Sheet Title <br />OVERALL FLOOR PLAN <br />Sheet No. <br />A=1 <br />■Released for Construction <br />❑Not Released for Construction <br />